2
2. SPECIFICATIONS
2-1. Unit Specifications
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks: Rating conditions are:
Cooling: Indoor air temperature 27°C D.B. / 19°C W.B.
Outdoor air temperature 35°C D.B. / 24°C W.B.
Heating: Indoor air temperature 20°C D.B.
Outdoor air temperature 7°C D.B. / 6°C W.B.
Power Source
240 V Single phase 50Hz
Voltage rating
V
240
Cooling
Capacity
kW
8.
5
0
BTU/h
2
9
,
0
00
Air circulation (High)
m
3
/h
1,110
Moisture removal (High)
Liters/h
3.4
Available voltage range
V
216 to 264
Running amperes
A
13.
2
Power input
W
3,1
5
0
Power factor
%
99
C.O.P.
W/W
2.
70
Compressor locked rotor amperes
A
63
Controls / Temperature control
Microprocessor / I.C. thermostat
Control unit
Wireless remote control unit
Timer
1-hour OFF / 12-hour ON or OFF
Fan speeds
Indoor / Outdoor
3 and Auto / Auto (Hi, Lo)
Airflow direction (Indoor)
Horizontal
Manual
Vertical
Auto
Air filter
Washable, Anti-Mold
Compressor
Rotary (Hermetic)
Refrigerant / Amount charged at shipment
g
R22 / 2,
6
00
Refrigerant control
Capillary tube
Operation sound
Indoor – Hi / Me / Lo
dB-A
47 / 41 / 38
Outdoor – Hi
dB-A
54
Refrigerant tubing connections
Flare type
Max. allowable tubing length at shipment
m
7.5
Refrigerant tube
Narrow tube
mm (in.)
9.52 (3/8)
diameter
Wide tube
mm (in.)
15.88 (5/8)
Refrigerant tube kit / Accessories
Optional / Hanging wall bracket
Indoor Unit
Outdoor Unit
Unit dimensions
Height
mm
330
735
Width
mm
1,140
940
Depth
mm
228
340
Package dimensions
Height
mm
325
826
Width
mm
1,231
1,016
Depth
mm
406
416
Weight
Net
kg
18.0
71.0
Shipping
kg
20.0
77.0
Shipping volume
m
3
0.16
0.35
Dimensions & Weight
Features
Electrical Rating
Performance
Indoor Unit
SAP – K30
3
A
Outdoor Unit
SAP – C30
3
A