6
2-2-2. Outdoor Unit
Outdoor Unit
SAP – C92AH
Controller PCB
—
Compressor
Type
Rotary (Hermetic)
Compressor model
C-R92H5W 80692945-S
Nominal output
W
900
Compressor oil ... Amount
cc
4GSD-T or SAY-56T ... 550
Coil resistance (Ambient temp. 25°C)
Ω
C–R : 3.07
C–S : 7.97
Safety devices
Type
External(OLR A)
External(OLR T)
Overload relay
MRA99057-9201
CS-7C115
Operating temp.
Open
°C
145±5
115±3
Close
°C
69±11
95±5
Operating amp.(Ambient temp. 25°C)
Trip in 6 to 16 sec. at 18A
—
Run capacitor
µF
22.5
VAC
400
Crank case heater
—
Fan & Fan Motor
Type
Propeller
Q'ty ... Dia.
1 ... ø370
Fan motor model ... Q'ty
UE6-21AH5PD-S ... 1
No. of poles ... rpm (230 V, High)
6 ... 760
Nominal output
W
20
Coil resistance (Ambient temp. 20°C)
Ω
WHT-BRN : 356.4
WHT-PNK : 439.5
Safety devices
Type
Thermal fuse
Operating temp.
Open
°C
145 ± 2
Close
°C
—
Run capacitor
µF
1.5
VAC
440
Heat Exch. Coil
Coil
Aluminum plate fin / Copper tube
Rows
1
Fin pitch
mm
1.2
Face area
m
2
0.333
External Finish
Acrylic baked-on enamel finish
DATA SUBJECT TO CHANGE WITHOUT NOTICE.