2-3. Other Component Specifications
8
This power relay is provided to protect the outdoor fan to operate in Low fan speed during heating mode.
In heating operation, the outdoor fan should always run in High fan speed to prevent the unit from freezing.
PTC Thermistor (TH)
ZPROYCE101A500
Rating
400V, 115A
4-way Valve (20S)
LB81012 (Coil), VK1100B (Valve)
Coil rating
AC 220/240V, 50/60Hz, 6W
Coil resistance
Ω
(at 20
°
C)
3,030
±
7%
NOTE
Power Relay (for outdoor fan motor)
HH62S AC220/240V
Coil rating
AC 220/240V
Contact rating
AC 250V, 10A
Thermostat (Fan Speed Control 23S)
MQT5S
Switching temp.
°
C
high
➞
LOW
28.5
°
C
±
1.5
low
➞
HIGH
31.5
°
C
±
2
Contact rating
AC 220V, 3A
Outdoor Unit
SAP – C122AH
4-way Valve (20S)
LB81012 (Coil), VK1100B (Valve)
Coil rating
AC 220/240V, 50/60Hz, 6W
Coil resistance
Ω
(at 20
°
C)
3,030
±
7%
Outdoor Unit
SAP – C92AH
Thermistor (Room sensor)
DTN-TKS128B
Resistance
k
Ω
25
°
C
5.0
±
3%
Thermistor (Coil sensor)
DTN-TKS131B
Resistance
k
Ω
0
°
C
15.0
±
2%
Transformer (TR)
ATR-I55
Rating
Primary
AC 230V, 50 / 60 Hz
Secondary
13.7V, 0.4A
Capacity
5.48VA
Coil resistance
Ω
(at 25
°
C)
Primary (WHT – WHT):
307
±
10%
Secondary (BRN – BRN):
1.8
±
10%
Thermal cut-off temp.
150
°
C
Indoor Unit
SAP – K92AH
SAP – K122AH