Operation with the Remote Control Unit (continued)
•
This appliance has a built-in 3-minute time delay circuit to ensure
reliable operation. When the operation button is pressed, the
compressor will start running within three minutes. In the event of
power failure, the unit will stop. When the power is restored, the
unit will restart automatically after three minutes.
2. Adjusting the
Fan Speed
A. Automatic
Simply set the FAN SPEED selector to the
position.
A microcomputer in the air conditioner automatically controls the fan
speed when the
mode is selected. When the air conditioner starts
operating, the difference between the room temperature and the set
temperature is detected by the microcomputer which then automatically
switches the fan speed to the most suitable level.
Cooling and DRY mode:
When difference between
room temperature and set
temperature is
FAN SPEED
2 ˚C and over
High
Between 2 ˚C and 1 ˚C
Medium
Below 1 ˚C
Low
13
OI-
005
-13EG
ope-in oi229000
The above table assumes that the sensor on the remote control is being
used. If the sensor on the indoor unit is being used (the indicator is on),
actual operation may differ slightly from the operation described in the
table.
(Refer to “A/C SENSOR button” on page 9.)
B. Manual
If you want to adjust fan speed manually during operation, just set the
FAN SPEED selector as desired. [
,
, or
]
NOTE
NOTE