16
Indoor Unit
SAP – K121AA
Outdoor Unit
SAP – C121AA
240V Single Phase 50Hz
RATING CAPACITY
3.40 kW
AIR FLOW RATE
470 m
3
/h
EVAPORATOR
CONDENSER
ENT. TEMP. °C
OUTDOOR AMBIENT TEMP. °C
W.B.
D.B.
30
35
40
43
TC
3.13
2.98
2.80
2.58
CM
1.05
1.13
1.17
1.36
21
SHC
2.06
1.98
1.88
1.77
15
23
SHC
2.29
2.20
2.11
1.99
25
SHC
2.51
2.43
2.33
2.22
27
SHC
2.74
2.65
2.56
2.44
29
SHC
2.96
2.88
2.78
2.58
31
SHC
3.13
2.98
2.80
2.58
TC
3.36
3.20
3.00
2.76
CM
1.08
1.16
1.20
1.39
21
SHC
1.83
1.75
1.65
1.54
17
23
SHC
2.06
1.97
1.88
1.76
25
SHC
2.28
2.20
2.10
1.99
27
SHC
2.51
2.42
2.33
2.21
29
SHC
2.73
2.65
2.55
2.44
31
SHC
2.96
2.87
2.78
2.66
TC
3.57
#
3.40
3.20
2.94
CM
1.11
1.19
1.24
1.43
21
SHC
1.59
1.50
1.41
1.29
19
23
SHC
1.81
1.73
1.63
1.52
25
SHC
2.04
1.95
1.86
1.74
27
SHC
2.26
2.18
2.08
1.97
29
SHC
2.49
2.41
2.31
2.19
31
SHC
2.71
2.63
2.54
2.42
TC
3.78
3.60
3.39
3.12
CM
1.14
1.23
1.28
1.47
23
SHC
1.56
1.48
1.39
1.27
21
25
SHC
1.79
1.71
1.61
1.50
27
SHC
2.01
1.93
1.84
1.72
29
SHC
2.24
2.16
2.06
1.95
31
SHC
2.46
2.38
2.29
2.17
TC
4.01
3.78
3.54
3.29
CM
1.17
1.26
1.31
1.50
23
25
SHC
1.52
1.43
1.33
1.23
27
SHC
1.74
1.65
1.55
1.46
29
SHC
1.97
1.88
1.78
1.68
31
SHC
2.19
2.10
2.01
1.91
TC :
Total Cooling Capacity (kW)
SHC : Sensible Heat Capacity (kW)
CM :
Compressor Input (kW)