17
6. ELECTRICAL DATA
6-1. Electrical Characteristics
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
240V Single phase 50Hz
Rating Conditions
Running Amps.
A
0.18
0.24
5.48
5.9
Power Input
kW
0.040
0.058
1.192
1.29
Full Load Conditions Running Amps.
A
0.18
0.24
6.78
7.2
Power Input
kW
0.040
0.058
1.502
1.60
Rating Conditions
: Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.
Indoor Unit
SAP – K121AA
Outdoor Unit
SAP – C121AA
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
240V Single phase 50Hz
Rating Conditions
Running Amps.
A
0.18
0.25
3.47
3.9
Power Input
kW
0.040
0.060
0.83
0.93
Full Load Conditions Running Amps.
A
0.18
0.25
4.27
4.7
Power Input
kW
0.040
0.060
0.99
1.09
Rating Conditions
: Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.
Indoor Unit
SAP – K91AA
Outdoor Unit
SAP – C91AA