background image

PLC-XW200/250 Expand Serial Command Functional Specifications 

                                                                                   

                                                                               

43 / 64 

 

9.4.13  CR_IMAGE Command 

Command  “CR_IMAGE”[CR] 

Details 

Get image setting status 
Required  data  “CUSTOM1” to “CUSTOM4”  is  the  same as “Image1”  to “Image4” 
displayed when selecting IMAGE on OSD menu 

Response 

Acceptable 

“000_%a”[CR] 

%a 

“DYNAMIC” --------------------------------------- Dynamic 
“STAND” ------------------------------------------- Standard 
“REAL” --------------------------------------------- Real 
“CINEMA” ----------------------------------------- Cinema 
“BLACKBOARD” -------------------------------- Blackboard 
“COLORBOARD” -------------------------------- Colorboard 
“CUSTOM1”~”CUSTOM4” -------------------- Image1~4 

Unacceptable 

“Error  Code”[CR]  ----  When  the  command  is  invalid  due  to 

condition such as Input source 

 

9.4.14  CR_IMGGMD Command 

Command  "CR_IMGGMD”[CR] 

Details 

Get Image Gamma setting status 

Response 

Acceptable 

“000_%a”[CR] 

%a 

“DYN” ------------ Dynamic 
“STD” ------------ Standard   
“REL” ------------ Real   
“CNM” ----------- Cinema   
“BKB” ------------ Blackboard   
“CLB” ------------ Colorboard   

Unacceptable  “Error Code”[CR]   

 

 

 

Summary of Contents for PLC-XW200

Page 1: ...EXPAND SERIAL COMMAND FUNCTIONAL SPECIFICATIONS PLC XW200 PLC XW250 Ver 1 01 SANYO Electric Co Ltd DS Company Projector Division ...

Page 2: ... Table 11 6 1 Image Status Read Command Table 11 6 2 PC Adjust Status Read Command Table 11 6 3 Video Status Read Command Table 11 6 4 Input Status Read Command Table 11 6 5 Screen Status Read Command Table 11 6 6 Lamp Status Read Command Table 12 6 7 Sound Status Read Command Table 12 6 8 Setting Status Read Command Table 12 6 9 Other Status Read Command 12 7 Error Code Table 13 8 Functional Exec...

Page 3: ...d 22 8 6 1 CF_INPUT Command 22 8 6 2 CF_SOURCE Command 22 8 6 3 CF_INPUT1 Command 23 8 6 4 CF_INPUT2 Command 23 8 6 5 CF_INPUT3 Command 23 8 6 6 CF_INPUT_ 1_ 2 Command 23 8 6 7 CF_SYSTEM Command 24 8 7 Screen Control Command 25 8 7 1 CF_SCREEN Command 25 8 7 2 CF_DZCENT Command 25 8 7 3 CF_KEYSTONE Command 25 8 7 4 CF_KYSTNMODE Command 26 8 7 5 CF_VSCALE Command 26 8 7 6 CF_VPOS Command 26 8 7 7 C...

Page 4: ...N STA Command 34 8 10 17 CF_RCODE Command 34 8 10 18 CF_KEYDIS Command 35 8 10 19 CF_PJPINCODE Command 35 8 10 20 CF_FANMODE Command 35 8 10 21 CF_FANCONTROL Command 36 8 10 22 CF_CCAPTIONDISP Command 36 8 10 23 CF_CCAPTIONCOLOR Command 36 8 10 24 CF_FILTIMER Command 36 8 10 25 CF_FILH Command 37 8 10 26 CF_FDEFAULT Command 37 8 11 Other Command 38 8 11 1 CF_KEYENU Command 38 8 11 2 CF_MENU Comman...

Page 5: ...POS Command 44 9 5 5 CR_V POS Command 44 9 5 6 CR_DDOTS Command 45 9 5 7 CR_DLINE Command 45 9 5 8 CR_PCSTORE Command 45 9 6 Video Status Read Command 46 9 6 1 CR_SERSYS Command 46 9 7 Input Status Read Command 47 9 7 1 CR_INPUT Command 47 9 7 2 CR_SOURCE Command 47 9 7 3 CR_SRCINP1 Command 47 9 7 4 CR_SRCINP2 Command 47 9 7 5 CR_SRCINP3 Command 47 9 7 6 CR_SYSTEM Command 48 9 7 7 CR_SYSLIST Comma...

Page 6: ...ACKGND Command 56 9 11 6 CR_DISP Command 56 9 11 7 CR_LOGO Command 56 9 11 8 CR_CEIL Command 56 9 11 9 CR_REAR Command 56 9 11 10 CR_TERMINAL Command 57 9 11 11 CR_STANDBYMODE Command 57 9 11 12 CR_P MANE Command 57 9 11 13 CR_P MANETIME Command 57 9 11 14 CR_ON STA Command 57 9 11 15 CR_RCODE Command 58 9 11 16 CR_SECURITY Command 58 9 11 17 CR_KEYDIS Command 58 9 11 18 CR_PJLOCKNOW Command 58 9 ...

Page 7: ...and Serial Command Functional Specifications 6 64 9 12 3 CR_VMUTE Command 61 9 12 4 CR_FREEZE Command 61 9 12 5 CR_PTIMER Command 62 9 12 6 CR_TEMPWARN Command 62 9 12 7 CR_TEMP Command 63 9 12 8 CR_TEMPFAIL Command 64 ...

Page 8: ...ommands are defined as Expand Serial Commands 2 Serial Interface Specification 2 1 Transfer Specification Item Specification Synchronous System Asynchronous Transmission Speed 9600 19200 Data Length 8 bit Parity N A Stop Bit 1 Flow Control N A Note1 Transmission Speed initial setting value is 19200 Note2 Transmission Speed can be changed in service mode 2 2 Connection Dedicated serial cable must b...

Page 9: ...or CF_BRIGHT_032 CR Next Command Projector PC 000 CR Response A few ms 5s When a computer sends next command before receiving a response the projector may not operate properly except when there is no response for more than 5 seconds 5 It takes about 5 seconds for internal initialization after plugging in AC power During this time commands cannot be processed Do not issue any command 4 Name Definit...

Page 10: ... Value CF_H POS_ 1 CR Set Horizontal Position value CF_V POS_ 1 CR Set Vertical Position value CF_DDOTS_ 1 CR Set Display Dots value CF_DLINE_ 1 CR Set Display Line value CF_PCSTORE_ 1 CR Store current values of PC Adjust at Mode 1 5 CF_PCMODEFREE_ 1 CR Relese registered values of Mode1 5 5 3 Input Control Command Table Execute command Item CF_INPUT_ 1 CR Select Input CF_SOURCE_ 1 CR Select Input ...

Page 11: ... function CF_REAR_ 1 CR Set Rear function CF_TERMINAL_ 1 CR Set Terminal function CF_STANDBYMODE_ 1 CR Set Standby Mode CF_P MANE_ 1 CR Set Power management function CF_P MANETIME_ 1 CR Set Power management time CF_ON STA_ 1 CR Set Power ON Start function CF_RCODE_ 1 CR Select Remote Control Reception Code CF_KEYDIS_ 1 CR Disable RC Projector keys CF_PJPINCODE_ 1 CR Input PIN code to release PJ Lo...

Page 12: ...R Get setting value of Vertical Position CR_DDOTS CR Get setting value of Display Dots CR_DLINE CR Get setting value of Display Line CR_PCSTORE CR Get Free or Stored status for PC Adj mode1 5 6 3 Video Status Read Command Table Status read command Item CR_SERSYS CR Get selected current signal When in Auto mode it returns a result by Auto detect 6 4 Input Status Read Command Table Status read comma...

Page 13: ...g status of Terminal CR_STANDBYMODE CR Get setting status of Standby Mode CR_P MANE CR Get setting status of Power management CR_P MANETIME CR Get setting time for Power management CR_ON STA CR Get setting status of ON Start CR_RCODE CR Get selected Remote Control Code CR_SECURITY CR Get setting status of Security CR_KEYDIS CR Get RC KEY disability status CR_PJLOCKNOW CR Get if PJ Lock is actually...

Page 14: ... Not reflected 103 Command mismatched to Hardware command for Optional function which is not installed 201 When reached upper or lower limit of increasing or decreasing data 301 Command cannot be executed during capturing display Resend the command after a while 302 Command cannot be executed during Auto PC operation Resend the command after a while 402 Command cannot be executed during PIN code o...

Page 15: ...Acceptable 8 3 Operation Requirements 1 Functional Execution Command is limited when the projector status is as below However Status Read Command is effective even under these conditions Projector Status Available Functional Execution Command Standby Mode C00 POWER ON Countdown in process C00 POWER ON Terminates Countdown C01 POWER OFF C02 POWER OFF Terminates Countdown Cooling down in process N A...

Page 16: ...nby mode or ALL is OFF The value is held in Suspend mode This command is available in normal Power ON status Response Acceptable 000 CR Unacceptable Error Code CR 8 4 3 CF_COLOR Command Command CF_COLOR_ 1 CR 1 000 063 Directly select Color setting value UP Current Color setting value 1 DN Current Color setting value 1 Details Set Color value of user control Projector does not save the value set w...

Page 17: ... is held in Suspend mode This command is available in normal Power ON status Response Acceptable 000 CR Unacceptable Error Code CR 8 4 7 CF_WBAL Command Command CF_WBAL 1_ 2 CR 1 R Red G Green B Blue 2 000 063 Directly select Color value specified by White Balance 1 UP Current Color value set by White Balance 1 1 DN Current Color value set by White Balance 1 1 Details Set Color value set by White ...

Page 18: ...tive order OFF FILM L2 L1 OFF Details Noise Reduction based on frame correlation Select L1 or L2 depending on motion detection L2 is more effective in reducing noise than L1 however L2 can have a blur in moving image Projector does not save the value set with this command so that it returns its original when projector turning into Stanby mode or ALL is OFF The value is held in Suspend mode This co...

Page 19: ... CF_IMAGEADJ Command Command CF_IMAGEADJ_ 1 CR 1 RST Reset Image adjustment STR1 Store current Image adjustment to Image 1 STR2 Store current Image adjustment to Image 2 STR3 Store current Image adjustment to Image 3 STR4 Store current Image adjustment to Image 4 Details Reset store Image adjustment Parameter STR1 to STR4 is the same as Image1 to Image4 displayed when adjusting Image on OSD menu a...

Page 20: ...o Stanby mode or ALL is OFF This command is available in normal Power ON status Response Acceptable 000 CR Unacceptable 101 CR when Input for Video is selected 8 5 3 CF_CLAMP Command Command CF_CLAMP_ 1 CR 1 mmmm nnnn Directly select Clamp setting value mmmm shows minimum value fixed value 0001 nnnn shows maximum value it depends on input signal UP Current Clamp setting value 1 DN Current Clamp se...

Page 21: ...tal Dots value Horizontal Position value Even number is available and when odd number is set it is rounded out UP Current Display Dots setting value 2 DN Current Display Dots setting value 2 Details Set Display Dots value of PC signal Projector does not save the value set with this command so that it returns its original when projector turning into Stanby mode or ALL is OFF This command is availab...

Page 22: ...y as storing to Mode1 Mode5 in PC Adjust MENU This command is available in normal Power ON status Response Acceptable 000 CR Unacceptable 101 CR When Input for Video is selected 8 5 9 CF_PCMODEFREE Command Command CF_PCMODEFREE_ 1 CR 1 MODE1 Set Mode1 to Free status MODE2 Set Mode2 to Free status MODE3 Set Mode3 to Free status MODE4 Set Mode4 to Free status MODE5 Set Mode5 to Free status Details D...

Page 23: ...urns 101 by selecting Computer 2 while Monitor out is selected in Terminal menu Response Acceptable 000 CR Unacceptable Error Code CR 8 6 2 CF_SOURCE Command Command CF_SOURCE_ 1 CR 1 Input is Computer 1 ANALOG Select Analog Input YPBPR Select Component Input S VIDEO Select S Video Input SCART Select Scart Input UP Switch Input as follows Analog YPBPR S Video Scart DN Switch Input as follows Scart...

Page 24: ...le 000 CR Unacceptable Error Code CR 8 6 5 CF_INPUT3 Command Command CF_INPUT3_ 1_ CR 1 VIDEO Select Composite video Input Details Select Videoinput This command is available in normal Power ON status Response Acceptable 000 CR Unacceptable Error Code CR 8 6 6 CF_INPUT_ 1_ 2 Command Command CF_INPUT_ 1_ 2 CR 1 COMPUTER1 Select Computer1 Input COMPUTER2 Select Computer2 Input VIDEO Select Analog In...

Page 25: ...ect PAL M PAL N Select PAL N 1080I Select 1080i 1035I Select 1035i 720P Select 720p 575P Select 575p 480P Select 480p 575I Select 575i 480I Select 480i Details Select System of currently selected Input When Input specified by 1 is inappropriate for selected Input the projector returns 101 CR and the command is not executed This command is available in normal Power ON status Note1 NTSC NTSC4 43 PAL...

Page 26: ...Input the projector returns 101 CR and the command is not executed DZOOM UP and DZOOM DN start effecting from the first command This command is available in normal Power ON status Note When Input is computer and AV sorts signals 480i 575i etc are entered the signal recognized as Video Input Response Acceptable 000 CR Unacceptable Error Code CR 8 7 2 CF_DZCENT Command Command CF_DZCENT_ 1 CR 1 CENT...

Page 27: ... Code CR 8 7 5 CF_VSCALE Command Command CF_VSCALE_ 1 CR 1 032 32 031 31 002 2 001 1 000 0 01 1 02 2 31 31 32 32 UP Vertical Scale setting value 1 DN Vertical Scale setting value 1 Details Set Vertical Scale This command is available in normal Power ON status Note1 When Screen setting is not in Custom mode projector changes image mode into Custom by receiving this command Note2 When there is no si...

Page 28: ...e in normal Power ON status Note1 When Screen setting is not in Custom mode projector changes image mode into Custom by receiving this command Note2 When there is no signal detected projector returns 101 and the command does not excute Response Acceptable 000 CR Unacceptable Error Code CR 8 7 8 CF_HPOS Command Command CF_HPOS_ 1 CR 1 015 15 014 14 002 2 001 1 000 0 01 1 02 2 14 14 15 15 UP Horizon...

Page 29: ...gh Normal Eco High DN Switch Lamp mode backward Eco Normal High Eco Details Select Lamp Mode The value set by this command is stored in EEPROM and its setting is effective even after ALL is OFF This command is available in normal Power ON status Response Acceptable 000 CR Unacceptable Error Code CR 8 8 3 CF_LAMPLIFECONTRL Command Command CF_LAMPLIFECONTRL_ 1 CR 1 MODE1 Set Lamp life mode to Mode1 ...

Page 30: ... and RC and directly select Volume setting value When setting Volume value the Sound Mute ON status is canceled just like RC operation The value set by this command is stored in Projector This command is available in normal Power ON status Response Acceptable 000 CR Unacceptable Error Code CR 8 9 2 CF_MUTE Command Command CF_MUTE_ 1 CR 1 ON Set Sound Mute to ON OFF Set Sound Mute to OFF Details Co...

Page 31: ...UPOSITION_ 1 CR 1 SET Move the menu display to next position Details Change the menu position This command is available in normal Power ON status The language set by this command is stored in EEPROM and its setting is effective after ALL is OFF Position top left top right center bottom left bottom right top left Response Acceptable 000 CR Unacceptable Error Code CR 8 10 3 CF_INPUTSEARCH Command Co...

Page 32: ... and Input search to OFF at once e g If projector receives Keystone OFF command while Auto PC ADJ and Input search are OFF it returns error code 101 Response Acceptable 000 CR Unacceptable Error Code CR 8 10 6 CF_AUTOSETUP Command Command CF_AUTOSETUP_ 1 CR 1 START Execute Auto Setup Details Excute Auto Setup Note CF commands does not execute while Auto setup is in process If the command is sent d...

Page 33: ...g in positive order OFF DFLT User OFF DN Switch Logo setting in negative order OFF User DFLT OFF Details Set Cancel Logo The value set by this command is stored in EEPROM and its setting is effective even after ALL is OFF This command is available in normal Power ON status 1 Set LOGO PIN CODE When LOGO LOCK is in operation PIN CODE is correct Command is valid Acceptable PIN CODE is incorrect Comma...

Page 34: ...stored in EEPROM and its setting is effective after ALL is OFF This command is available in normal Power ON status Response Acceptable 000 CR Unacceptable Error Code CR 8 10 12 CF_TERMINAL Command Command CF_TERMINAL_ 1 CR 1 COMPUTER Set Input mode MONITOR Set Monitor Out mode Details Set Terminal setup This command is available in normal Power ON status Terminal means Computer 2 in this model Res...

Page 35: ...y this command is stored in EEPROM and its setting is effective after ALL is OFF This command is available in normal Power ON status Response Acceptable 000 CR Unacceptable Error Code CR 8 10 16 CF_ON STA Command Command CF_ON STA_ 1 CR 1 ON Set Power On Start to ON OFF Set Power On Start to OFF UP Switch setting On Off On DN Switch setting On Off On Note UP and DN behave the same Details Set Canc...

Page 36: ... Command is invalid Error Code 102 PIN CODE is out of 1 range Command is invalid Error Code When PJ LOCK is not in operation PIN CODE is within 1 range Command is valid Acceptable PIN CODE is out of 1 range Command is invalid Error Code This command is valid during a dialog PJ PIN CODE is displayed after Power On and Count down Also when PJ LOCK setting is On1 it is necessary to transmit this comm...

Page 37: ...in normal Power ON status Closed caption is available under conditions below Entered signal is appropriate Video NTSC signal of S video Component 480i and System is fixed to NTSC or 480i Response Acceptable 000 CR Unacceptable Error Code CR 8 10 23CF_CCAPTIONCOLOR Command Command CF_CCAPTIONCOLOR_ 1 CR 1 COLOR Select Color WHITE Select White Details Select color of Closed caption The status set wi...

Page 38: ...ror Code CR 8 10 25CF_FILH Command Command CF_FILH_ 1 CR 1 RST Reset Filter used time Details Reset filter used time Response Acceptable 000 CR Unacceptable Error Code CR 8 10 26CF_FDEFAULT Command Command CF_FDEFAULT_ 1 CR 1 RST Details Set the value to Factory Default This command is available in normal Power ON status Response Acceptable 000 CR Unacceptable Error Code CR ...

Page 39: ...acceptable Error Code CR 8 11 2 CF_MENU Command Command CF_MENU_ 1 CR 1 ON Display OSD Menu OFF Cancel OSD menu Details Display Cancel On Screen Display Menu This command is available in normal Power ON status Response Acceptable 000 CR Unacceptable Error Code CR 8 11 3 CF_POWER Command Command CF_POWER_ 1 CR 1 ON Power ON projector OFF Power OFF Projector Note1 Count down can be terminated by sen...

Page 40: ...ower ON status Response Acceptable 000 CR Unacceptable Error Code CR 8 11 5 CF_VMUTE Command Command CF_VMUTE_ 1 CR 1 ON Set No show ON OFF Set No show OFF UP Switch setting On Off On DN Switch setting On Off On Note UP and DN behave the same Details Set Cancel No show setting This command is available in normal Power ON status Response Acceptable 000 CR Unacceptable Error Code CR 8 11 6 CF_PTIMER...

Page 41: ...r Example Get total dots of projector by Expand Commands PC PJ CR_TDOTS CR PC PJ 000_1344 CR 9 3 Operation Condition 1 Basically Status Read Commands should be always operated 2 When Eco mode is selected in Standby mode of Setting menu and projector is in Standby Status Read Commands are invalid 9 4 Image Status Read Command 9 4 1 CR_BRIGHT Command Command CR_BRIGHT CR Details Get Brightness value...

Page 42: ...9 4 5 CR_SHARP Command Command CR_SHARP CR Details Get Sharpness value of user control Response Acceptable 000_ a CR a 000 015 Unacceptable Error Code CR 9 4 6 CR_GAMMA Command Command CR_GAMMA CR Details Get Gamma value of user control Response Acceptable 000_ a CR a 000 015 Unacceptable Error Code CR 9 4 7 CR_WBAL R Command Command CR_WBAL R CR Details Get White Balance Red value of user control...

Page 43: ...OR Colorboard selected BLANK White Balance has been changed Unacceptable Error Code CR 9 4 11 CR_NZRED Command Command CR_NZRED CR Details Get setting status of Noise Reduction Response Acceptable 000_ 1 CR 1 L1 Noise Reduction for moving image L2 Noise Reduction for still image OFF Noise Reduction is OFF Unacceptable Error Code CR 9 4 12 CR_PROGV Command Command CR_PROGV CR Details Get setting st...

Page 44: ...se Acceptable 000_ a CR a DYNAMIC Dynamic STAND Standard REAL Real CINEMA Cinema BLACKBOARD Blackboard COLORBOARD Colorboard CUSTOM1 CUSTOM4 Image1 4 Unacceptable Error Code CR When the command is invalid due to condition such as Input source 9 4 14 CR_IMGGMD Command Command CR_IMGGMD CR Details Get Image Gamma setting status Response Acceptable 000_ a CR a DYN Dynamic STD Standard REL Real CNM Ci...

Page 45: ...d due to condition such as Input source 9 5 3 CR_CLAMP Command Command CR_CLAMP CR Details Get Clamp value Response Acceptable 000_ a CR a 0001 nnnn nnnn depends on input signal Unacceptable Error Code CR When the command is invalid due to condition such as Input source 9 5 4 CR_H POS Command Command CR_H POS CR Details Get Horizontal Position value Response Acceptable 000_ a CR a 0000 nnnn nnnn T...

Page 46: ...t Display Line value Response Acceptable 000_ a CR a 0100 nnnn nnnn Total Line Vertical Position value Unacceptable Error Code CR When the command is invalid due to condition such as Input source 9 5 8 CR_PCSTORE Command Command CR_PCSTORE CR Details Get Free Stored status of MODE1 MODE5 for PC Adjust Each data consists of 5 bytes Each byte indicates the status of MODE1 MODE5 respectively F Free S...

Page 47: ...turns auto detected signal in Auto mode Only available for Video input N A when Input is computer Response Acceptable 000_ a CR a 1080I60 1080i 60Hz 1080I50 1080i 50Hz 1035I 1035i 720P 720p 575P 575p 480P 480p 575I 575i includes Composite signal such as PAL 480I 480i includes Composite signal such as NTSC NO_SIGNAL There is no signal Unacceptable 101 CR When Input for PC is selected ...

Page 48: ...able Error Code CR 9 7 3 CR_SRCINP1 Command Command CR_SRCINP1 CR Details Get selected source of Input 1_CMP1 Response Acceptable 000_ 1 CR Request data ANALOG Analog RGB Input is selected YPBPR YPBPR Input is selected S VIDEO S Video Input is selected SCART Scart Input is selected Unacceptable Error Code CR 9 7 4 CR_SRCINP2 Command Command CR_SRCINP2 CR Details Get selected source of Input 2_CMP2...

Page 49: ... selected MODE5 Mode5 is selected When there is no signal projector returns error code 101 CR Input is Y Pb Cb Pr Cr AUTO Auto is selected 1080i 1080i is selected 1035i 1035i is selected 720p 720p is selected 575p 575p is selected 480p 480p is selected 575i 575i is selected 480i 480i is selected Projector returns selected System status regardless of the signal input Input is Video S Vi deo AUTO Au...

Page 50: ...e 480I 480i is selectable Projector does not return Error Code 101 evev if there is no signal When Input is Video S Video Returns all the System titles on Menu including Auto AUTO Auto is selectable PAL PAL is selectable SECAM SECAM is selectable PAL N SECAM is selectable Projector does not return Error Code 101 evev if there is no signal Unacceptable Error Code CR 9 7 8 CR_MODELIST Command Comman...

Page 51: ... When the command is invalid due to condition such as Input source 9 8 2 CR_ KYSTNMODE Command Command CR_KYSTNMODE CR Details Get setting status of Keystone Store Mode Response Acceptable 000_ a CR a STR Store mode is Store RST Store mode is Reset Unacceptable Error Code CR 9 8 3 CR_VSCALE Command Command CR_VSCALE CR Details Get setting status of Vertical Scale Store Mode Response Acceptable 000...

Page 52: ...and Serial Command Functional Specifications 51 64 9 8 6 CR_HPOS Command Command CR_HPOS CR Details Get setting status of Horizontal Position Store Mode Response Acceptable 000_ 1 CR 1 15 015 Unacceptable Error Code CR ...

Page 53: ...ptable Error Code CR 9 9 2 CR_LAMPH Command Command CR_LAMPH CR Details Get total running time of lamp by hour h Actual running time not corresponding value Response Acceptable 000_ 1 CR 1 00000 99999 Unacceptable Error Code CR 9 9 3 CR_LAMPCORRESPH Command Command CR_LAMPCORRESPH CR Details Get total running time of lamp by hour h Corresponding value not actual running time Response Acceptable 00...

Page 54: ...amp is ON and No 2Lamp is OFF 4IOXI 4 lamps model and No 1 No 4 lamps are ON No 2 lamp is OFF and No 3 model is failed Unacceptable Error Code CR 9 9 6 CR_PROJH Command Command CR_PROJH CR Details Get total running time of Projector by hour h Response Acceptable 000_ 1 CR 1 0000000 0099999 Unacceptable Error Code CR 9 9 7 CR_HMLAMP Command Command CR_HMLAMP CR Details Get lamp number Response Acce...

Page 55: ...Command Command CR_VOLUME CR Details Get Volume value of user control Response Acceptable 000_ a CR a 000 031 Unacceptable Error Code CR 9 10 2 CR_MUTE Command Command CR_MUTE CR Details Get sound mute setting status Response Acceptable 000_ a CR a ON Sound Mute is ON OFF Sound Mute is OFF Unacceptable Error Code CR ...

Page 56: ...d TUR Turkish is selected KAZ Kazakh is selected Unacceptable Error Code CR 9 11 2 CR_INPUTSEARCH Command Command CR_INPUTSEARCH CR Details Get setting status of Input search Response Acceptable 000_ a CR a OFF Input search is OFF ON1 Input search is On1 ON2 Input search is On2 Unacceptable Error Code CR 9 11 3 CR_AUTOSETUPPCADJ Command Command CR_AUTOSETUPPCADJ CR Details Get Auto PC adj setting ...

Page 57: ...Display is ON OFF Display is OFF CNTDWNOFF Countdown OFF Unacceptable CR 9 11 7 CR_LOGO Command Command CR_LOGO CR Details Get setting status of Logo Response Acceptable 000_ 1 CR 1 OFF Logo function is OFF DFLT Default Logo is selected USER User Logo is selected Unacceptable CR 9 11 8 CR_CEIL Command Command CR_CEIL CR Details Get setting status of Ceiling Response Acceptable 000_ 1 CR 1 ON Ceili...

Page 58: ...1 12CR_P MANE Command Command CR_P MANE CR Details Get Power management setting status Response Acceptable 000_ a CR a OFF Power Management is OFF READY Power Management is Ready SHUTDOWN Power Management is set to Shut Down mode Unacceptable Error Code CR 9 11 13 CR_P MANETIME Command Command CR_P MANETIME CR Details Get time to start Power Management Response Acceptable 000_ a CR a 001 030 1 min...

Page 59: ... Acceptable 000_ a CR a NONE RC Projector keys are valid RC RC keys are invalid KEY Projector keys are invalid Unacceptable Error Code CR 9 11 18 CR_PJLOCKNOW Command Command CR_PJLOCKNOW CR Details Get if PJ lock is actually in operation Response Acceptable 000_ 1 CR 1 LOCK PJ Lock is in operation PJ Lock status is ON 1 or ON 2 on Menu and PJ PIN CODE is not entered so that projector is actually ...

Page 60: ...is ON3 Unacceptable Error Code CR 9 11 22CR_FILH Command Command CR_FILH CR Details Get Filter used time Response Acceptable 000_ 1 CR 1 00000 99999 0 hour to 99999 hours Unacceptable Error Code CR 9 11 23CR_CCAPTIONDISP Command Command CR_CCAPTIONDISP CR Details Get selected channel of Closed caption Response Acceptable 000_ a CR a OFF Off CC1 CC1 is selected CC2 CC2 is selected CC3 CC3 is select...

Page 61: ...nt time Response Acceptable 000_ 1 CR 1 1Y Over filter replacement time 1N Within filter replacement time Unacceptable Error Code CR 9 11 26CR_FILTIMER Command Command CR_FILTIMER CR Details Get setting time which filter warning OSD is displayed Response Acceptable 000_ 1 CR 1 100 100 hours 200 200 hours 300 300 hours OFF No OSD display Unacceptable Error Code CR ...

Page 62: ...21 Cooling down due to Lamp failure 81 Stand by after Cooling down due to Lamp failure Unacceptable Error Code CR 9 12 2 CR_SIGNAL Command Command CR_SIGNAL CR Details Get Signal status if there is signal or not Response Acceptable 000_ a CR a ON Signal is found OFF There is no signal Unacceptable Error Code CR 9 12 3 CR_VMUTE Command Command CR_VMUTE CR Details Get setting status of No Show Respo...

Page 63: ... Acceptable 000_ a_ b_ c CR a b c a Sensor 1 status b Sensor 2 status c Sensor 3 status W Approach or reach abnormal temperature dangerous temperature S Far from abnormal temperature safe temperature N Sensor detects no abnormal temperature Example S_W_S CR means Sensor 1 detects safe temperature Sensor 2 detects abnormal temperature and Sensor 3 detects safe temperature Note When the temperature ...

Page 64: ...igh to display Warning S Not close to abnormal temperature Temperature is low enough and safe N Applicable sensor does not detect abnormal temperature E Not able to return temperature data When several sensors are incorporated projector returns values continuously e g _31 5F__35 2S__38 0W CR A data of sensor 1 comes first and a data of sensor 2 follws after 1 space As described respectively in e g...

Page 65: ...5F CR _ indicates a space When the temperature sinks to the first character is like 05 5F CR The last character means the sensor s status if it reaches abnormal temperature Exceeding critical temp F Temp is safe S Sensor detects no critical temp N The example shows that sensor 1 indicates 31 5 degrees and the temperature is abnormal When the temperature is safe all data are represented as 000S Whe...