-26-
After replacing the Power Board, PF.C. Board, readjust
the Output voltage adjustment as follows.
1. Connect a digital voltmeter to pins 1 (+) and 3 (-) of
K6D
.
2. Adjust the voltage by using
VR611
as following.
AC Input
Reading
230V 370V
±2V
or 120V
340V
±2V
Caution:
Be sure to connect the lamp when taking this adjust-
ment.
●
Circuit Adjustments
CAUTION: The each circuit has been made by the fine adjustment at factory. Do not attempt to adjust the follow-
ing adjustments except requiring the readjustments in servicing otherwise it may cause loss of per-
formance and product safety.
[Adjustment Condition]
●
Input signal
Video signal .......................... 1.0Vp-p/75
Ω
terminated, 16 steps gray scale (Composite video signal)
Computer signal...................... 0.7Vp-p/75
Ω
terminated, 16 steps gray scale pattern (XGA)
●
Picture control mode ...................... “STANDARD” mode unless otherwise noted.
Note:
* Please refer to “Service Adjustment Menu Operation” for entering to the service mode and adjusting the service
data.
Electrical Adjustments
Output Voltage adjustment
1. Enter the service mode and select group no. “
11
” and
item no. “
0
”. Set data value to “
1
”.
2. Connect a digital voltmeter to test point “TP12V1” (+)
and chassis ground (-). Select item no. “
1
” and change
data value to adjust voltage to be 7.5 ±0.1V.
3. Connect a digital voltmeter to test point “TP12V2” (+)
and chassis ground (-). Select item no. “
2
” and
change data value to adjust voltage to be 9.0 ±0.1V.
4. Select group no. “
11
” and item no. “
0
” and set data
value to “
3
”.
5. Connect a digital voltmeter to test point “TP12V1” (+)
and chassis ground (-). Select item no. “
3
” and change
data value to adjust voltage to be 13.5 ±0.1V.
6. Connect a digital voltmeter to test point “TP12V2” (+)
and chassis ground (-). Select item no. “
4
” and change
data value to adjust voltage to be 13.5 ±0.1V.
Fan Voltage adjustment
[For PLC-XU32/XU37]
1. Enter the service mode and select group no. “
11
” and
item no. “
0
”. Set data value to “
1
”.
2. Connect a digital voltmeter to test point “TP12V1” (+)
and chassis ground (-). Select item no. “
1
” and change
data value to adjust voltage to be 8.0 ±0.1V.
3. Connect a digital voltmeter to test point “TP12V2” (+)
and chassis ground (-). Select item no. “
2
” and
change data value to adjust voltage to be 9.0 ±0.1V.
4. Select group no. “
11
” and item no. “
0
” and set data
value to “
3
”.
5. Connect a digital voltmeter to test point “TP12V1” (+)
and chassis ground (-). Select item no. “
3
” and change
data value to adjust voltage to be 13.5 ±0.1V.
6. Connect a digital voltmeter to test point “TP12V2” (+)
and chassis ground (-). Select item no. “
4
” and change
data value to adjust voltage to be 13.5 ±0.1V.
Fan Voltage adjustment
[For PLC-XU33/XU38]
Summary of Contents for PLC-XU32
Page 48: ... 48 CXA2101AQ RGB Matrix IC4101 IC Block Diagrams BA7078AF Selector IC6241 ...
Page 49: ... 49 CXD2064Q Digital Comb Filter IC2101 L3E01031 Level Shift IC3531 IC3561 IC Block Diagrams ...
Page 51: ... 51 ML60851 USB I F IC9801 M62393 D A IC2571 IC Block Diagrams ...
Page 52: ... 52 TA1318N AFC Detector IC6171 TB1274AF Video Decoder IC1101 IC Block Diagrams ...
Page 86: ... MK8A Jul 2002 BB 400 Printed in Japan SANYO Electric Co Ltd ...
Page 112: ...Diagrams Drawings PLC XU32 XU33 XU37 XU38 2002 Jul ...