-44-
Electrical Adjustments
Group/
Item
Item Name
Function
Initial
range Note
3 Temp B-A Warning (High)
Temp. B-A to judge the Temp Error at
High (Clogging Det.)
100
100
100
100
0-100
4 Temp C-A Warning (High)
Temp. C-A to judge the Temp Error at
High (Clogging Det.)
100
100
100
100
0-100
5 Temp A Warning (Normal)
Temp. A to judge the Temp Error at
Normal (Room)
46
46
46
46
30-100
6 Temp B Warning (Normal)
Temp. B to judge the Temp Error at
Normal (Panel)
60
61
56
54
30-100
7 Temp C Warning (Normal)
Temp. C to judge the Temp Error at
Normal (Lamp)
65
65
63
63
30-100
8 Temp B-A Warning (Normal) Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
100
100
100
100
0-100
9 Temp C-A Warning (Normal) Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
100
100
100
100
0-100
10 Temp A Warning (Eco)
Temp. A to judge the Temp Error at
Eco (Room)
46
46
45
45
30-100
11 Temp B Warning (Eco)
Temp. B to judge the Temp Error at
Eco (Panel)
60
61
55
54
30-100
12 Temp C Warning (Eco)
Temp. C to judge the Temp Error at
Eco (Lamp)
65
64
62
62
30-100
13 Temp B-A Warning (Eco)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
100
100
100
100
0-100
14 Temp C-A Warning (Eco)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
100
100
100
100
0-100
15 Temp A Warning Offset
(Temp)
Offset of Temp Error (Temp.)
Error Setting Value is increased XC at
the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
5
0-100
16 Temp B Warning Offset
(Temp)
5
0-100
17 Temp C Warning Offset
(Temp)
15
0-100
18 Temp B-A Warning Offset
(Temp)
0
0-100
19 Temp C-A Warning Offset
(Temp)
0
0-100
20 Temp A Warning Offset
(Time)
Offset of Temp Error (Minutes)
Error Setting Value is increased X
minute at the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
5
0-100
21 Temp B Warning Offset
(Time)
5
0-100
22 Temp C Warning Offset
(Time)
18
0-100
23 Temp B-A Warning Offset
(Time)
1
0-100
24 Temp C-A Warning Offset
(Time)
1
0-100
25 Factory Mode
For factor use
0
0-1
Group
254
Fan control range Setting (temp./Voltage)
Normal Ceiling HiLand-
Normal
HiLand-
Ceiling
0 High Fan Control Min Temp
Temp Senser Control Start/End Temp.
at High
38
38
34
33
20-100
1 High Fan Control Max Temp
43
43
40
38
20-100
2 High Fan1 Min
Fan voltage value at High (unit: 0.1V)
85
85
105
105
0-255
3 High Fan1 Max
135
135
135
135
0-255
4 High Fan2 Min
85
85
110
110
0-255
5 High Fan2 Max
130
130
130
130
0-255
6 High Fan3 Min
75
75
100
100
0-255
7 High Fan3 Max
77
77
115
115
0-255
8 High Fan4 Min
9999
9999
-
9 High Fan4 Max
9999
9999
-
10 Normal Fan Control Min
Temp
Temp Senser Control Start/End Tem.
p at Normal
38
39
35
33
20-100
11 Normal Fan Control Max
Temp
43
43
40
38
20-100
12 Normal Fan1 Min
Fan voltage value at Normal (unit:
0.1V)
70
70
95
95
0-255
13 Normal Fan1 Max
125
125
125
125
0-255
14 Normal Fan2 Min
75
75
100
100
0-255
15 Normal Fan2 Max
120
120
120
120
0-255
16 Normal Fan3 Min
85
85
105
105
0-255
17 Normal Fan3 Max
85
85
110
110
0-255
18 Normal Fan4 Min
9999
9999
-
19 Normal Fan4 Max
9999
9999
-
20 Eco Fan Control Min Temp
Temp Senser Control Start/End Tem.
p at Eco
38
39
35
32
20-100
21 Eco Fan Control Max Temp
42
43
39
38
20-100
22 Eco Fan1 Min
Fan voltage value at Eco (unit: 0.1V)
60
60
95
95
0-255
23 Eco Fan1 Max
115
115
115
115
0-255
24 Eco Fan2 Min
68
68
90
90
0-255
25 Eco Fan2 Max
110
110
110
110
0-255
Summary of Contents for PLC-XU116
Page 65: ... 65 IC Block Diagrams FA5550NG P F Control IC621 IC87F2G08A5AT6 UART IC9885 ...
Page 66: ... 66 IC Block Diagrams SP3232ECYP RS 232C Driver IC3801 MR4010 Power OSC IC631 ...
Page 68: ... 68 IC Block Diagrams PW190 Scaler IC301 ...
Page 104: ... KC8AC February 2010 DC 200 Printed in Japan SANYO Electric Co Ltd ...