- 15 -
■
Mechanical disassemblies
1
Lamp Unit and Alarm Battery removal.
Disassemble should be made following procedures in numerical order.
Following steps show the basic procedures, therefore unnecessary step may be ignored.
Caution:
The parts and screws should be placed exactly the same position as the original other-
wise it may cause lose of performance and product safety.
The wiring method of the leads and ferrite cores should be returned exactly the same
state as the original, otherwise it may cause lose of performance and product safety.
Screws Expression
(Type
Diameter x Length
) mm
T type
M
T
ype
Tapping screw
Machine screw
1. Remove the screw-A(M3x8) and remove the Lamp cover.
. Loosen the screws-B and remove the Lamp uint.
3. Remove the Air Filter upward.
Lamp Cover
A
B
Lamp Unit
Air Filter
Summary of Contents for PLC-XE50A
Page 77: ... 77 IC Block Diagrams BA7078 Sync Separator IC5301 AN5870 Signal Switch IC5201 ...
Page 78: ... 78 FA5502 P F Control IC601 HIN202EIB RS 232C Driver IC3801 IC Block disgrams ...
Page 80: ... 80 L3E01060 Level Shift IC2501 IC2531 IC2561 M62334 DAC IC3501 IC Block disgrams ...
Page 81: ... 81 NJW1141 Audio Control IC5001 PW190 Scaler IC301 IC Block disgrams ...
Page 107: ... 107 MecanicalParts Location Integrator Lens In L09 L14 Relay Lens Out S6 S6 S6 S6 ...
Page 110: ...SM5111160 00 PLC XE50A Dec 2009 DC 200 Printed in Japan SANYO Electric Co Ltd ...