-60-
Troubleshooting
No Power
lamp cover switch
Make sure that the lamp cover is mounted correctly. If
not or the lamp cover removed, the lamp does not light
on for the safety. Check the lamp cover and lamp cover
switch (SW90).
-
When all of led indicators are not lighting
, the symptom indicates that the primary power supply circuit does
not operate properly. Check the power primary circuit and parts as follow;
AC cord, F601 (Fuse), Power board,
SW601 (Thermal sw.) short in normal
SW601 opens when the surrounding temperature of the switch exceeds 85°C.
This projector provides a function which can be specified a defective area simply by indicating the LEDs. Connect the
AC cord and press the Power button once and then check the LED indication.
-
When the WArNING (red) and PoWer (red) indicators are blinking
, the symptom indicates that the projec-
tor detected an abnormal temperature risen inside the projector. Check the air filters and remove the object near
the intake and exhaust fan openings, and wait until the POWER indicator stops blinking, and then try to turn on
the projector.
The internal temperature is monitored by sensor ICs, IC881, IC881 on the Main board and IC8811 on the
R/C board.
-
When the WArNING indicator lights red
, the symptom indicates that the projector detected an abnormality in
the cooling fan operation or in the power supply secondary circuits. Check fan operation and power supply lines,
and the driving signal status.
The P_FAIL signal (Error: L) is sent to pin 15 of IC01<SYSTEM CONTROL> when the abnormality occurred
inside the projector, and then the IC01 sends the shutdown signal, LAMP_DC_ON, to the power supply circuit
to stop its operation, and signal LAMP_SCI to the lamp ballast board via IC4891 and SW90<lamp cover switch>
to stop operation of the lamp circuit.
An abnormality occurs on the secondary power supply;
Check power supplies S16V, S6V, S-5V. P_FAIL signal becomes “Low” when the abnormality occurs on
any of the power supply lines.
An abnormality occurs on the fan control circuit;
Check FN001, FN00, FN00, FN004, FN005 and peripheral circuit.
If any of the fans has an error, the fan lock signal drives Q601 becomes "High". As the result, signal
FAN_ERR becomes Low and is sent to lamp ballast board to stop lamp circuit.
An abnormality occurs on the drive signals;
ON_150V signal (Power-on: H) is output from pin 95 of IC01 and switches IC59,15.5VL supply circuit,
ON_V signal (Power-on: H) is output from pin 188 of IC01 and switches IC561, 1.0V and Q58 V
supply circuit.
LAMP_DC_ON signal (Power-on: H) is output from pin 89 of IC01 and supplied to the P.C Control IC,
IC61, on the power supply board through Q691, and PC66.
LAMP_SCI signal (Power-on: H) is output from pin 14 of IC9885 and applied to pin of IC4891 and out
put pin 4 and then supplied to the lamp ballast board through SW90<Lamp Cover SW>.
LAMP_DET signal at the pin 85 of IC01 is applied from the lamp ballast unit. If the abnormality occurred
on the lamp ballast unit, LAMP_DET signal becomes “High” and then IC01 shuts down the power supply
circuit.
Summary of Contents for PLC-XE33
Page 65: ... 65 IC Block Diagrams FA5550NG P F Control IC621 LC87F2G08A5AN6 UART IC9885 ...
Page 68: ... 68 IC Block Diagrams PW190 Scaler IC301 MR4010 Power OSC IC631 ...
Page 69: ... 69 IC Block Diagrams PIC18F67J60 LAN CONTROL IC8801 FA7703 DC DC Converter IC7811 ...
Page 93: ...KD8 XE3300 93 Mechanical Parts List ...
Page 94: ... KD8AC August 2009 DC 200 Printed in Japan SANYO Electric Co Ltd ...
Page 104: ...A10 SCH_KR5AC NO DATA ...
Page 108: ...A14 PCB_KR5AC NO DATA ...