background image

PLV-HD2000    Basic Serial Command Functional Specifications 

 

 

6/24

 

4.  Functional Execution Command Table 

Command 

Item 

Command

Item 

C00 

POWER ON 

C43 

FREEZE ON 

C01 

POWER OFF 
(Immediate Power OFF) 

C44 FREEZE 

OFF 

C05 

INPUT 1 

C46 

ZOOM - 

C06 INPUT 

C47 ZOOM 

C07 

INPUT 3 

C4A 

FOCUS - 

C08 

INPUT 4 

C4B 

FOCUS + 

C09 

----- 

C5D 

LENS SHIFT UP 

C0A 

----- 

C5E 

LENS SHIFT DOWN 

C0B 

----- 

C5F 

LENS SHIFT LEFT 

C0C 

----- 

C60 

LENS SHIFT RIGHT 

C0D 

VIDEO MUTE ON 

C70 

FULL LAMP MODE 

C0E 

VIDEO MUTE OFF 

C71 

HALF LAMP MODE (Lamp1&4)

C0F 

SCREEN NORMAL SIZE   

C72 

HALF LAMP MODE (Lamp2&3)

C10 

SCREEN FULL SIZE   

C89 

AUTO IMAGE 

C1C MENU 

ON 

   

C1D MENU 

OFF 

   

C1E DISPLAY 

CLEAR 

   

C27 IMAGE 

(Toggle) 

   

C3A POINTER 

RIGHT 

   

C3B POINTER 

LEFT 

   

C3C POINITER 

UP 

   

C3D POINITER 

DOWN 

   

C3F ENTER 

   

 

 

5. 

State Read Command Table

 

Command 

Item 

CR0 Status 

Read

 

CR1 

Input Mode Read

 

CR3 Lamp 

Time 

Read 

CR4 Setting 

Read 

CR6 Temp 

Read 

CR7 

Lamp Mode Read 

CR9 PC 

Type 

Read 

CRA 

Status 2 Read 

 

 

Summary of Contents for LP-HD2000

Page 1: ...BASIC SERIAL COMMAND FUNCTIONAL SPECIFICATIONS LP HD2000 SANYO Electric Co Ltd Home Electronics Group AV Company Projector Business Unit ...

Page 2: ...POWER OFF 9 6 7 INPUT 1 Command 9 6 8 NPUT 2 Command 9 6 9 INPUT 3 Command 9 6 10 NPUT 4 Command 10 6 11 VIDEO MUTE ON Command 10 6 12 IDEO MUTE OFF Command 10 6 13 SCREEN NORMAL SIZE Command 10 6 14 SCREEN FULL SIZE Command 10 6 15 MENU ON Command 10 6 16 MENU OFF Command 11 6 17 DISPLAY CLEAR Command 11 6 18 IMAGE Command 11 6 19 POINTER RIGHT Command 11 6 20 POINTER LEFT Command 11 6 21 POINTER...

Page 3: ...ADJ Command 14 7 Status Read Command 15 7 1 Format 15 7 2 Transfer Example 15 7 3 Status Read Command 16 7 4 Input Mode Read Command 19 7 5 Lamp Time Read Command 19 7 6 Setting Read Command 19 7 7 Temp Read Command 20 7 8 Lamp Mode Read Command 20 7 9 PC Type Read Command 21 7 10 Status 2 Read Command 21 8 Command with Address Specification 22 8 1 Overview 22 8 2 Functional Execution Command with...

Page 4: ...tems Specification Synchronous system Asynchronous Transmission Speed 9600 19200 Data Length 8 bits Parity None Stop Bit 1 Flow Control None 1 Transmission speed initial setting value is 19200 2 Transmission speed can be changed in Service Mode 2 2 Connection Dedicated serial cables that come with a projector must be used for the connection between a computer and the projector PC Projector COM 1 S...

Page 5: ... the response except when there is no response for 5 seconds Projector takes about 7 seconds for the internal initialization after plugging in AC until it moves to Standby mode During this time the projector cannot process commands Do not issue any command For 7 seconds after executing Power ON operation in Stand by mode the projector receives a command and returns the response but does not execut...

Page 6: ...C0B C5F LENS SHIFT LEFT C0C C60 LENS SHIFT RIGHT C0D VIDEO MUTE ON C70 FULL LAMP MODE C0E VIDEO MUTE OFF C71 HALF LAMP MODE Lamp1 4 C0F SCREEN NORMAL SIZE C72 HALF LAMP MODE Lamp2 3 C10 SCREEN FULL SIZE C89 AUTO IMAGE C1C MENU ON C1D MENU OFF C1E DISPLAY CLEAR C27 IMAGE Toggle C3A POINTER RIGHT C3B POINTER LEFT C3C POINITER UP C3D POINITER DOWN C3F ENTER 5 State Read Command Table Command Item CR0...

Page 7: ...ction requiring command pipelining the operation should follow the same way as in remote control Sending side system issues commands every 100ms When receiving an applicable command the function is executed repeatedly for 120ms When receiving the same commands in sequence within 120ms the function is repeatedly executed for another 120ms from the moment of the second command reception When there i...

Page 8: ...tor Status Available Functional Execution Commands Standby mode C00 POWER ON Countdown in process C00 POWER ON Countdown is terminated Cooling Down in process NONE Cooling Down due to Abnormal Temperature NONE Abnormal Temperature status NONE Mode switching in process NONE Power Management Cooling Down in process NONE Power Management mode C00 POWER ON C01 POWER OFF Note In above status the projec...

Page 9: ...aying Power OFF message unlike the operation with ON OFF button of the projector or remote control Acceptable ACK CR Response Unacceptable CR 6 7 INPUT 1 Command COMMAND C05 CR Detail Select INPUT1 Note When there is no board inserted to INPUT1 it is not executed Acceptable ACK CR Response Unacceptable CR 6 8 INPUT 2 Command COMMAND C06 CR Detail Select INPUT2 Note When there is no board inserted ...

Page 10: ...ble ACK CR Response Unacceptable CR 6 12 IDEO MUTE OFF Command COMMAND C0E CR Detail Turn off NO SHOW This command works the same way as NO SHOW button of the remote control but it works only for turning off NO SHOW function not for turning on Acceptable ACK CR Response Unacceptable CR 6 13 SCREEN NORMAL SIZE Command COMMAND C0F CR Detail Set screen size to Normal Acceptable ACK CR Response Unacce...

Page 11: ...ble ACK CR Response Unacceptable CR 6 19 POINTER RIGHT Command COMMAND C3A CR Detail Move Pointer of on screen display Menu to the right This command works the same way as button of the projector Acceptable ACK CR Response Unacceptable CR 6 20 POINTER LEFT Command 6 21 POINTER UP Command COMMAND C3C CR Detail Move upward Pointer of on screen display Menu This command works the same way as button o...

Page 12: ...MAND C44 CR Detail Cancel Freeze status This command works the same way as FREEZE button of the remote control but only for turning off Freeze function not for turning on Acceptable ACK CR Response Unacceptable CR 6 26 ZOOM Command COMMAND C47 CR Detail Scale up screen image This command works the same way as Z button of the remote control Acceptable ACK CR Response Unacceptable CR 6 27 ZOOM Comma...

Page 13: ... lens is moved forward This command works the same way as F button of the remote control Acceptable ACK CR Response Unacceptable CR 6 30 LENS SHIFT UP Command COMMAND C5D CR Detail Move screen image upward Acceptable ACK CR Response Unacceptable CR 6 31 LENS SHIFT DOWN Command COMMAND C5E CR Detail Move screen image downward Acceptable ACK CR Response Unacceptable CR 6 32 LENS SHIFT LEFT Command C...

Page 14: ... 2 lamps then to all lamps again or switching from 2 lamps to all lamps then to 2 lamps again allow about 90 seconds of preparation time for lamp lighting Acceptable ACK CR Response Unacceptable CR 6 36 HALF LAMP MODE 2 SET Command COMMAND C72 CR Detail Set to HALF LAMP Mode 2 lamp mode Lamps No 2 No 3 are set Usually when HALF LAMP Mode is set the projector automatically chooses lamps but with th...

Page 15: ...eives the applicable command it returns the required data as a string Required Data CR Required Data string Refer to Status Read Command Table When the received data cannot be decoded the projector returns CR 7 2 Transfer Example Get currently selected input for the projector by sending Basic Command Command issue the current input read command PC Projector C R 1 CR Projector PC 1 CR Response A fe...

Page 16: ...e is projected normally on screen 80 CR Status Standby When the status is Standby Status Read Commands are always accepted while Functional Execution Commands are not accepted except POWER ON command 40 CR Status Countdown in process When Display in the Setting menu is set to ON executing Power ON starts countdown operation When Display in the Setting menu is set to OFF the status moves to Immedia...

Page 17: ...Cooling Down is executed for given time and it moves to Standby mode 02 CR Status RS 232C Commands can not be accepted When receiving this response re send the Status Read Command 24 CR Status Power Management Cooling Down in process When Power management function is set to ON in setting menu and no signal status continues for 5 minutes projector turns off the lamp s and enters the Power Managemen...

Page 18: ...mp fails to be turned on projector automatically moves to Cooling Down status 21 CR is returned in this case 81 CR Status Standby after Cooling Down operation has been executed due to Lamp Failure 81 CR is returned which indicates the status is moved to Standby after completing lamp failure operation This status is kept until another operation is performed ...

Page 19: ...o 2 3 lamp No 3 4 lamp No 4 e g 0410 0410 0410 0410 CR indicating Lamp No 1 410 Hours Lamp No 2 410 Hours Lamp No 3 410 Hours Lamp No 4 410 Hours Note 9999 is returned when the time is over 10000 hours Response Unacceptable CR 7 6 Setting Read Command COMMAND CR4 CR Detail Get screen setting status of Ceiling and Rear Acceptable 1 CR 1 11 CR Normal Screen setting 10 CR Picture is top bottom revers...

Page 20: ...cond sensor s data Response Unacceptable CR 7 9 Lamp Mode Read Command COMMAND CR7 CR Detail Get Lamp Mode for the multiple lamp projector It is possible to get Lamp mode information for the multiple lamp projector It can also get the information about the failure of lamp lighting Acceptable 1 CR 1 e g 0F CR The first digit indicates Lamp Mode 0 4 lamps mode 1 2 lamps mode Lamp No 1 4 2 2 lamps mo...

Page 21: ...Mode1 20 Go_PC_adj Auto No_signal No signal Response Unacceptable CR 7 11 Status 2 Read Command COMMAND CRA CR Detail Get the operating status of Video Mute Acceptable 1 CR 1 Indicates setting status of No show No Show ON OFF ON 1 OFF 0 There is a signal no signal No signal 1 Signal 0 e g Normal operation 00 No show is on 01 No signal 80 81 When it is in Standby mode or during Cooling Down operati...

Page 22: ... command is represented as Basic Command or Expand Command with address such as A001 The commands are the same when controlling one projector by a computer e g Functional Execution Command A001C05 CR e g Status Read Command A001CR0 CR Projectors have the function to set up its address in Service Mode Initial setting is No 001 Possible range is 001 to 999 It clears the received buffer in this case ...

Page 23: ...ving Functional Execution Command 0x06 0x0D CR When the received data cannot be decoded However when address is FFF it executes the function but does not return the response 8 2 2 When the command pipelining is needed When it needs the command pipelining the operation follows the specification below Sending side system issues commands every 100ms When receiving an applicable command the function i...

Page 24: ...Command CR Address 3 digit number 001 999 Command string Refer to Basic Commands or Expand Commands When the only projectors that have the address matching with the one in the received data decode the received command and it returns the required data as a string Required Data CR Required Data string Refer to Basic Status Read Command Table When the received data cannot be decoded it returns CR ...

Reviews: