![Sanyo CLT-99 Service Manual Download Page 8](http://html.mh-extra.com/html/sanyo/clt-99/clt-99_service-manual_360423008.webp)
-13-
-12-
ADJUSTMENT
CH (No.)
Tx Freq.
Rx Freq.
Rx Local
Tx Freq.
Rx Freq.
Rx Local
(MHz)
(MHz)
Freq. (MHz)
(MHz)
(MHz)
Freq. (MHz)
1
49.730
30.050
19.355
30.050
49.730
39.035
2
49.845
30.100
19.405
30.100
49.845
39.150
3
49.860
30.125
19.430
30.125
49.860
39.165
4
49.770
30.150
19.455
30.150
49.770
39.075
5
49.875
30.175
19.480
30.175
49.875
39.180
6
49.830
30.200
19.505
30.200
49.830
39.135
7
49.890
30.225
19.530
30.225
49.890
39.195
8
49.930
30.375
19.680
30.375
49.930
39.235
9
49.990
30.325
19.630
30.325
49.990
39.295
10
49.970
30.300
19.605
30.300
49.970
39.275
1st IF : 10.695MHz 2nd IF : 455kHz
HANDSET
BASE STATION
10 CH Frequency List of Cordless Telephone
HANDSET TEST MODE SPECIFICATION
1. Overview
By operating the keyboard SW on the remote unit, the pass or fail of the completion process can be determined through the
status of the LEDs, the sound of the key monitor, etc.
2. Start up
(A) Startup of the TEST MODE by the microcomputer ports.
(i) Before power ON, set to LOW P71 (2 pin).
(ii) INITIAL CHANNEL = 10 CH VCO adjustment
(B) Startup of the TEST MODE by operation of Power ON.
(When the TEST MODE begins, a beep is heard).
(i) The TEST MODE is started up by pressing “1” and “9” keys simultaneously at power on.
(ii) INITIAL CHANNEL = 10 CH VCO adjustment
(C) In case of TEST MODE in this way, there are several ways to change the normal mode.
(i) Detect charge.
(ii) Turn off the power, and turn on the power.
3. High frequency adjustment mode/Call circuit inspection mode
(A) High frequency adjustment channel
(i) VCO ADJUSTMENT CHANNEL : 10 CH (TEST MODE startup)
Tx POWER ON / Rx POWER ON / Rx MUTE OFF
(ii) Tx ADJUSTMENT CHANNEL : 4 CH (FLASH key on)
Tx POWER ON / Rx POWER ON / Rx MUTE ON
(iii) Rx ADJUSTMENT CHANNEL : 6 CH (REDIAL/P key on)
Tx POWER ON / Rx POWER ON / Rx MUTE OFF
(B) Setting of PLL channel (01 ~ 10 CH)
(i) Press two numeric keys (01 ~ 10 : Channel No.). For example : TALK MODE 01 channel
➞
0 and 1 key
(ii) After, the following operation setting of Tx and Rx are the same number of channel.
a. * key
➞
Tx POWER ON
b. TALK / VOL key
➞
Tx DATA ON, Rx MUTE ON
c. END key
➞
Tx POWER OFF / Tx DATA OFF
(C) Volume Control
Volume Control “Loud / Normal” switch over each time the MEMORY key is pressed.
Initial volume is Normal. (Only Tx POWER ON).
(D) Rx MUTE ON / OFF
Rx MUTE ON / OFF switch over each time the CHANNEL key is pressed. (Only Tx POWER ON).
(E) Detection of battery low
BATT LED is ON.
(F) Key monitor inspection mode
(i) Each time a key is pressed, the TALK LED lights and the key monitor sounds.
(ii) Keys are pressed disorderly, and if after all keys have been pressed, the TALK LED lights for approximately 0.5 sec.
and a beep is heard.
1. Start Up
(A) Start up of the Test mode by the microcomputer ports.
Before power ON, select the microcomputer ports : 36 pin (high or low), 59 pin -53 pin (short or open),
62 pin - 54 pin (short or open).
(B) Start up of the TEST MODE by operation of power ON
(i) Continue pressing ‘ PAGE/INT” key.
(ii) Supply the power keeping “(a)”.
(iii) Set the TONE/PULSE switch to PULSE.
(iv) Set the TONE/PULSE switch to TONE.
(v) Release “PAGE/INT” key.
Test mode will be Handset Call Status. (Channel
➞
10 CH)
In case of Test mode in this way, there are several ways to change the usual mode.
(i) Detect charge.
(ii) Turn OFF the power
2. The states of test mode
(A) Change state, press “#” key and then press numeric key (1 or 2 or 3).
For example: Intercom Call
➞
“#”, “3”.
Or each time you press the “SPEAKER” key, the state No. is increased.
The states of test mode
State
State Name
Condition
LED
(i)
Handset Call
While “REDIAL/P” key is pressed, Tx DATA turns ON and Tx MUTE turns ON.
CHARGE/IN USE
(Set at PULSE mode & RINGER OFF)
(ii)
Base Station Call
By pressing “PAGE/INT” key each time, DTMF is sent (“1”, “2” ...).
CHARGE/ IN USE
(Speaker phone)
& SPEAKER
By pressing “REDIAL” key, PULSE dial is sent. (Set at TONE mode)
(iii)
Intercom Call
✱
Rx MUTE is ON. While “REDIAL/P” key is pressed, Tx DATA turns ON and
INTERCOM &
Tx MUTE turns ON.
SPEAKER
While an incoming call is detected, CHARGE/IN USE LED blinks and “RING”
is heard. (Set at TONE mode)
* NOTE: INTERCOM SPEAKERPHONE measurement is not possible at this lest mode.
BASE STATION TEST MODE SPECIFICATION
36 pin
59 pin-53 pin
62 pin-54 pin
Mode
Channel
(TEST)
(*key)
(Flash key)
HIGH
Open
Open
Usual Mode
-
Open
Open
Test Mode (Handset Call)
10 CH
LOW
Short
Open
Test Mode (Handset Call)
4 CH
Open
Short
Test Mode (Handset Call)
6 CH
CLT-99/SS (S/M) 6
12/1/00, 3:17 PM
8
Summary of Contents for CLT-99
Page 10: ... 17 16 EXPLODED VIEW HANDSET EXPLODED VIEW BASE STATION CLT 99 SS S M 6 12 1 00 3 17 PM 10 ...
Page 19: ... 35 34 BLOCK DIAGRAM HANDSET CLT 99 SS S M 6 12 1 00 3 18 PM 19 ...
Page 20: ... 37 36 BLOCK DIAGRAM BASE STATION CLT 99 SS S M 6 12 1 00 3 18 PM 20 ...
Page 21: ... 39 38 SCHEMATIC DIAGRAM HANDSET CLT 99 SS S M 6 12 1 00 3 18 PM 21 ...
Page 22: ... 41 40 SCHEMATIC DIAGRAM BASE STATION CLT 99 SS S M 6 12 1 00 3 18 PM 22 ...