UK5 Specification of expanding serial command
10. Specification Command with Address
Ver. Rev.A
Page
50
9. 13. 10 Model number Read Command
Command “CR MDL” [CR]
Detail
Read the Model number
Acceptable
“%1” [CR]
%1
“000 **********”
“**********” is model number.
Maximum length of model number is 10 characters.
Response
Unacceptable “?” [CR]
10. Specification Command with Address
10. 1 Outline
10. 1. 1 Command with address is to control multiple monitor sets through RS232C.
10. 1. 2 Command with address starts from ”A” finish with carriage return
0x0D
.
One Command consists of one line.
10. 1. 3 As soon as receiving carriage return(0x0D), decoding is started.
10. 1. 4 Address ”A001” is added on command such as Basic Command or extending command.
Example of functional execution Command
“A001C05”[CR]
Exapmel of Read Command
“A001CR0”[CR]
10. 1. 5 Below condition, receiving buffer is cleared.
Receiving LF
0x0A
or EOF
0x1A
Taking more than one second in receiving one Command.
Between receiving from first digit detecting carriage return.
10. 1. 6 Must keep response time within 60
s
10. 2 Functional execution command with address.
10. 2. 1 Format
Issuing from following Command from PC
“A” Address “C” Command [CR]
or
“A” Address “CF_” Command
“_”
Parameter [CR]
Address
3 digit from “
”
“
”
EControl for all monitor sets at once, “
” is assigned in the address.
The monitor sets decode then returns the status only when the receiving data including address existing.
[ACK]
CR
0x06
0x0D
, receiving functional command
“
”
C R
Receiving non readable data
Addressed with “
”, function is executive but no return data.