Presence of
Presence of
Presence of
Presence of
change
change
change
change
-
-
-
-
T2:Thermal Shock
(Repetition of high temp.
and low temp.)
・Crimped part, Gasket (Cell)
・Gas Release Vent, Cell Case (Cell)
・Finished state of Wound Electrodes (Cell)
・Pack (Plastic) Case
・Holding Member(Insulator, Insulation Tape, Both Sides Tape)
・Coating materials
T3:Vibration
(Vibration load)
・Finished state of Wound Electrodes (Cell)
・Electric wiring member
・Electronic Parts on a circuit board
・Cell Holding Member (Adhesive, Both Sides Tape, Lib of
Plastic Case )
T4:Shock(Shock load)
・Wiring Member
・Electronic Parts on a circuit board
・Cell Holding Member(Adhesive, Both Sides Tape, Lib of
Target model which is not a new type 3UR18650-2-T0638
Test Item (Function)
Test Item (Function)
Test Item (Function)
Test Item (Function)
The element which is given influence
The element which is given influence
The element which is given influence
The element which is given influence
T1:Altitude Simulation
(Decompression load)
・Crimped part, Gasket (Cell)
・Gas Release Vent, Cell Case (Cell)
・Pack (Plastic) Case
・Holding Member(Insulator, Insulation Tape, Both Sides Tape)
・Coating materials
Date:March 09,2010
B:Checklist for Judging New Type Battery or not
Confirmation of presence of change in “The element which is given influence”
(Change ⇒ ○、 No change ⇒ -)
When there is no change in all items, it is NOT considered to be a New Type Battery.
Model which UN regulation test has completed
3UR18650-2-T0627
-
-
-
-
New・Not new
Sanyo Energy(Suzou) Co.,Ltd.
Check
Judgment result
New Type or not
approval
Writing
T5:External Short
Circuit(Short current)
・Over-voltage Protection
・Current Control Device
・Safety Device of cell (Cell)
・Lead Tab
T6(Cell):Impact(Crash load)
・Separator (Cell)
・Insulation State in a cell (Cell)
T7(Pack):Overcharge(Charge
load)
・Overcharge Protection
・Thermal Device
・Safety Device of cell (Cell)
・Cell Holding Member(Adhesive, Both Sides Tape, Lib of
Plastic Case )