SM830044
– 57 –
4
4. Service procedures
4. Service procedures
(4)
Indoor unit does not run.
(Indoor fan and louver motor do not run.
0630_X_S
P.C.B. Ass’y is defective.
(5)
Some part does not operate.
(1) Indoor fan does not run.
• Check resistance of fan
motor winding.
• Check fan motor capacitor.
OK
Relay RY1 or RY2 on the
P.C.B. Ass’y is defective.
• Check fan rotation.
Rotate the fan gently once
or twice by hand.
0631_X_S
Check fan casing
for foreign matter
on the inside.
Remove foreign
matter or repair.
Repair or replace.
Fan cannot
be rotated.
Fan motor burnout
or foreign matter
in bearing.
OK
(2) Louver motor does not run.
• Check resistance of
louver motor winding.
P.C.B. Ass’y or remote
control unit is defective.
OK
0632_X_S
Summary of Contents for 854 012 22
Page 6: ... 6 SM830044 ...