1 1 . 5,1 00K AWB Adjustment
[Connection]
CJ CJ CJ
CJ CJ CJ
CJ CJ CJ
CJ
[Adjustment]
Measuring Point
TP141 [CP 1 )
(video output)
TP1 43 (GND)
TP1 41 O TP143
0
Measuring Equipment
Vectorscope
Color viewer 5, 1 OOK
Subject
All white pattern
Condition
CAMERA EE
ADJ. Location
ADJ. Value
EVR CH1 1 , CH 1 2
Preparation:
•
Short pin
@
and pin ® of J9001 .
Adjusting method:
1 . Set the gain so that the burst comes to the end of the
vectorscope.
2. Press the RESET key once.
3. Press the READ key once while pressing the AID key and
read out all the EVR data.
4. Adjust two EVRs of CH1 1 and CH 1 2 mutually so that the
luminance point displayed the white vector is positioned
on the center point as shown in the figure. (See page
5-1 O)
5. Press the WRT key once while pressing the AID key to
store the adjusting data.
1 2. 2,800K AWB Adjustment
[Connection]
[Adjustment]
Measuring Point
TP1 41 [CP 1 )
(video output)
TP1 43 (GN D)
TP1 41 O TP1 43
0
Measuring Equipment
Vectorscope
Color viewer 5, 1 OOK
Subject
All white pattern
Condition
CAM ERA EE
(Place L8A8s in front of the lens)
ADJ. Location
ADJ. Value
VR931 (R. G)
VR932 (8. G)
Preparation:
•
Short pin
@ ,
pin ® and pin ® of J9001 .
Adjusting method :
1 . Set the gain so that the burst comes to the end of the
vectorscope.
2. Adjust with the VR931 (R. G) and VR932 (8. G) so that
the luminance point displayed the white vector is
positioned on the center point as shown in the figure.
(See page 5-1 0)
- 5-9 -