     S1000 FOR SMOKING ROOM 

USER INSTRUCTIONS 

MAINTENANCE 

 

REGULARLY

:   

o

 

Check filters after using the unit for 2 weeks. If filters are dirty, change them (part # 
MSCFTR2). This will help lower air restrictions so to keep up the performance of the 
unit. Discard the 4 in filter: it is restricting the airflow. 

 

QUATERLY: 

o

 

Every 3 months check the lamps: if they are covered with dust, clean them with 
denatured alcohol

 

 

ANNUALLY: 

o

 

Change lamps (parts -see below) to maintain performance: make sure to put the same 
lamp in the same clamp. Do not interchange lamps as the blue end cap lamp works only 
with the VOC sensor. 

 

LMPHGXJ105- Dual zone lamp (yellow end cap) change every 2 years 

 

LMPHXJ105- All oxidation lamp (blue end cap) change every year 
 

 

3-4 ans

:  Change or have the sensor board recalibrated -contact SANUVOX 

 

WORKING INSTRUCTIONS 

The VOC sensor analyzes the air every 90 seconds. A 20-foot power cord connects it via a relay to 
the device to activate the second oxidizing lamp on demand. 
 
The S1000 unit runs continuously, so its regular lamp purifies the air constantly. This dual zone lamp 
(UVC / UVV) is enough when there are only one or two smokers. 
 
However, when cigarette smokes increase in the room, the VOC monitor that samples the air 
regularly, triggers the 2

nd

 lamp all UVV for period of 90 seconds. This will repeat itself until there is 

no more smoke detected: the all UVV lamp will then be shut down, leaving the first lamps on to 
continue the cleanup. 
 
 
 

SIMPLIFIED PROCESS

:  

 

Ashes in the “white” smoke will be trapped onto the filter

  

 

Nicotine molecules will be dried by the UVC rays than trapped in the filters without the tar like 
material that coats everything. 

 

VOC will be oxidised by the UVV, reducing substantially their olfactory perception.

 

 

It is very important that the fan processes the air rapidly.  

Changing the filters regularly is a must.  

Summary of Contents for S1000FX-GX

Page 1: ...ted in BX shield One 1 VOC sensor Fig 2 factory pre set LAMP INSTALLATION this step can be done later 1 Open the front door on the unit 2 Open the door access to the aluminum box by removing the two wing nuts see picture aside 3 Remove the BLUE END CAP LMPHXJ160 lamp from packaging use the gloves provided 4 Identify the ballast showing LMPHXJ160 follow the wire and insert it in the appropriate cla...

Page 2: ...ell you it works IMPORTANT you may have to calibrate the VOC Monitor refer to the monitor instructions or call Sanuvox WORKING INSTRUCTION The VOC sensor analyzes the air every 90 seconds A 20 foot power cord connects it via a relay to the device to activate the second oxidizing lamp on demand The S300 unit runs continuously so its regular lamp purifies the air constantly This dual zone lamp UVC U...

Page 3: ... closer your setting is to 3 4 vdc the faster the trigger will be MAINTENANCE INSTRUCTIONS Change pre filter part MSCFTR2 regularly each month or few weeks depending on number of smokers since it will fill rapidly with nicotine dust and will prevent a good airflow Check the filters after the first 2 3 weeks of installation The 4 inches filter can be discarded when full the pre filters will be enou...

Page 4: ...he VOC sensor analyzes the air every 90 seconds A 20 foot power cord connects it via a relay to the device to activate the second oxidizing lamp on demand The S1000 unit runs continuously so its regular lamp purifies the air constantly This dual zone lamp UVC UVV is enough when there are only one or two smokers However when cigarette smokes increase in the room the VOC monitor that samples the air...

Reviews: