S1000 FOR SMOKING ROOM
USER INSTRUCTIONS
MAINTENANCE
•
REGULARLY
:
o
Check filters after using the unit for 2 weeks. If filters are dirty, change them (part #
MSCFTR2). This will help lower air restrictions so to keep up the performance of the
unit. Discard the 4 in filter: it is restricting the airflow.
•
QUATERLY:
o
Every 3 months check the lamps: if they are covered with dust, clean them with
denatured alcohol
•
ANNUALLY:
o
Change lamps (parts -see below) to maintain performance: make sure to put the same
lamp in the same clamp. Do not interchange lamps as the blue end cap lamp works only
with the VOC sensor.
▪
LMPHGXJ105- Dual zone lamp (yellow end cap) change every 2 years
▪
LMPHXJ105- All oxidation lamp (blue end cap) change every year
•
3-4 ans
: Change or have the sensor board recalibrated -contact SANUVOX
WORKING INSTRUCTIONS
The VOC sensor analyzes the air every 90 seconds. A 20-foot power cord connects it via a relay to
the device to activate the second oxidizing lamp on demand.
The S1000 unit runs continuously, so its regular lamp purifies the air constantly. This dual zone lamp
(UVC / UVV) is enough when there are only one or two smokers.
However, when cigarette smokes increase in the room, the VOC monitor that samples the air
regularly, triggers the 2
nd
lamp all UVV for period of 90 seconds. This will repeat itself until there is
no more smoke detected: the all UVV lamp will then be shut down, leaving the first lamps on to
continue the cleanup.
SIMPLIFIED PROCESS
:
•
Ashes in the “white” smoke will be trapped onto the filter
•
Nicotine molecules will be dried by the UVC rays than trapped in the filters without the tar like
material that coats everything.
•
VOC will be oxidised by the UVV, reducing substantially their olfactory perception.
It is very important that the fan processes the air rapidly.
Changing the filters regularly is a must.