 SMOKING ROOM INSTALLATION 

INSTALLER INSTRUCTIONS 

These instructions are for a smoking room of a maximum of 7500 cu ft 

One box contains:  

 

One(1)  SANUVOX unit S1000FX-GX 

 

 

One(1) SUBKITVOCS1000 

The S1000FX GX unit will be factory modified to include: 

 

One(1) full oxidation J-lamp (UV-V 185nm) (blue end cap) 

 

One(1)  additional ballast and lamp bracket 

 

One(1)   inside relay (Fig 4) connected to the full oxidation lamp  

 

20 ft of wire (Fig 3) that can be inserted in BX shield.  

 

One(1)  

VOC sensor

(Fig 2) factory pre-set   

 

 

 

LAMP INSTALLATION (this step can be done later) 

1.

 

Open the front door on the unit. 

2.

 

Open the door access to the aluminum box by removing the two 
wing nuts. (see picture aside) 

3.

 

Remove the BLUE END CAP (LMPHXJ160) lamp from packaging: 
use the gloves provided. 

4.

 

Identify the ballast showing LMPHXJ160, follow the wire and insert 
it in the appropriate clamp, using the foam tape supplied.   

5.

 

Plug tightly the connector on the lamp 

6.

 

Repeat the operation with the second lamp (LMPHGXJ160). 

7.

 

Plug tightly the connector on the lamp 

8.

 

Put the cover back on with the 2 wingnuts. 

 

Fig 1 

Fig 2 

Fig 3 

Fig 4 

 

Summary of Contents for S1000FX-GX

Page 1: ...ted in BX shield One 1 VOC sensor Fig 2 factory pre set LAMP INSTALLATION this step can be done later 1 Open the front door on the unit 2 Open the door access to the aluminum box by removing the two wing nuts see picture aside 3 Remove the BLUE END CAP LMPHXJ160 lamp from packaging use the gloves provided 4 Identify the ballast showing LMPHXJ160 follow the wire and insert it in the appropriate cla...

Page 2: ...ell you it works IMPORTANT you may have to calibrate the VOC Monitor refer to the monitor instructions or call Sanuvox WORKING INSTRUCTION The VOC sensor analyzes the air every 90 seconds A 20 foot power cord connects it via a relay to the device to activate the second oxidizing lamp on demand The S300 unit runs continuously so its regular lamp purifies the air constantly This dual zone lamp UVC U...

Page 3: ... closer your setting is to 3 4 vdc the faster the trigger will be MAINTENANCE INSTRUCTIONS Change pre filter part MSCFTR2 regularly each month or few weeks depending on number of smokers since it will fill rapidly with nicotine dust and will prevent a good airflow Check the filters after the first 2 3 weeks of installation The 4 inches filter can be discarded when full the pre filters will be enou...

Page 4: ...he VOC sensor analyzes the air every 90 seconds A 20 foot power cord connects it via a relay to the device to activate the second oxidizing lamp on demand The S1000 unit runs continuously so its regular lamp purifies the air constantly This dual zone lamp UVC UVV is enough when there are only one or two smokers However when cigarette smokes increase in the room the VOC monitor that samples the air...