background image

8

Instruction Manual for IL COIL CLEAN & ITS VARIOUS MODELS

1-888-726-8869

www.sanuvox.com

1.  Insert half of the coupler inside a first support rod.

2.  Using a 1/4" hex head self-drilling screw, drill through the support rod 

and secure the coupler in place.

3.  Insert the other half of the coupler into a second support pipe and secure 

it again with a self-drilling screw.

4.  The assembly is completed with the coupler tube inside, thus joining 

two support rods.

 

You can now install IL units with longer support rods.

STEP 1

STEP 2

STEP 3

STEP 4

Using the Coupler to Join Multiple 3/4" Support Rods

In the event that the AHU side panels (that supports the IL Coil Clean assembly) are wider than the included 3/4" support rod or 

that the installation required multiple IL Coil Clean units, the coupler can be inserted between two or more 3/4" support rods of 

3/4" EMT conduit, allowing the support rods to be extended to desired length.

Step by Step Coupler Installation

Summary of Contents for IL COIL CLEAN

Page 1: ...d to the UV unit or system and all other safety precautions considered as best practices in the HVAC industry if applicable 9 When applicable local regulation may comprise more restrictive installation and or certification requirements The aforementioned requirements prevail on those of this document and the installer agree to conform to these at his own expense 10 Follow all the safety instructio...

Page 2: ...ion 5 Using the Coupler to Join Multiple 3 4 Support Rods 8 Step by Step Coupler Installation 8 OPERATION 9 How to Operate your Product 9 How to Read the LED Status Display 9 Dry Contacts for Building Automation Integration 9 MAINTENANCE 10 How to Replace Lamp s 10 Step by Step Lamp Replacement 10 How to Clean your Product 11 STORAGE 11 ULTRAVIOLETS UVC 11 ELECTRICAL RATINGS POWER CONSUMPTION AVAI...

Page 3: ...models are specialized products a sizing calculation must be prepared with your Sanuvox representative for your specific installation For information or recommendations on how to size your specific application please call SANUVOX at 1 888 726 8869 COMPONENTS How it Works The IL Coil Clean is an industrial evaporator coil cleaner that is installed in front of the coil of the air treatment systems I...

Page 4: ...ean orMULTI ILCoilClean aluminum extrusion a packaged UV lamp a support rod a ballast box and a basic installation kit The installation kit includes a UV caution decal a maintenance decal cotton gloves hex bolts 2 Phillips head screws 2 self tapping screws 2 nuts 2 lock washers 2 electrical connectors 2 clamp assemblies 2 mounting flanges 2 and a coupler Setup While selecting the appropriate locat...

Page 5: ...stalled vertically more rods and flanges are needed 3 Measure and cut the rod to desired length or assemble several rods using couplers if necessary NOTE For lengths over 66 or when using multiples IL Coil Clean units multiple support rods may be joined together by using a coupler included Refer to Using the Coupler to Join Multiple 3 4 Support Rods on page 8 4 Place the mounting flanges on both e...

Page 6: ... the mounting flanges Recommendations To ensure you protect users from direct UV exposure use a interlok switch on the access door The switch will stop the operation of the IL Coil Clean when the door is opened 10 Installation of the ballast box Remove the Phillips screws 4 from the ballast box cover Set aside the bag containing the Gaynor plug and lamp boot Mount the ballast box outside the air h...

Page 7: ...to the connection The lamp boot does not cover the entire end cap of the UV lamp but only approximately 3 4 15 There remains only the connection of the power supply which must be carried out by a certified electrician With the ballast box cover removed install a connector on the round knockout on the bottom of the ballast box Next pull an appropriate power cable into the box Insert the white neutr...

Page 8: ...embly is completed with the coupler tube inside thus joining two support rods You can now install IL units with longer support rods STEP 1 STEP 2 STEP 3 STEP 4 Using the Coupler to Join Multiple 3 4 Support Rods In the event that the AHU side panels that supports the IL Coil Clean assembly are wider than the included 3 4 support rod or that the installation required multiple IL Coil Clean units th...

Page 9: ...ast you will notice only one wire set in the ballast box as well as a black cap covering the second LED emplacement If there is two 2 ballasts there will be two wire set and two LED GREEN UV UNIT ON The unit is functioning normally YELLOW UV LAMP NEEDS REPLACEMENT Notifies the user that the UV lamp has reached the end of its lifespan and must be replaced FLASHING RED UV LAMP FAILURE Lamp has faile...

Page 10: ...ut gloves Step by Step Lamp Replacement 1 Disconnect all power before performing any maintenance or service With the power off remove the lamp from the reflector and unplug it 2 Release the old lamp from the reflector brackets and remove it CAUTION Use caution when removing and inserting UV lamps from the metal spring clamps 3 Use a new UV lamp Plug in the new lamp and place the rubber tip over th...

Page 11: ...N AVAILABLE VOLTAGE The IL Coil Clean and its various models has a power consumption that varies according to its lamp length 1 0 amps for 40 lamps 1 25 amps for 50 lamps and 1 5 amps for 60 lamps See product label to confirm power consumption of your specific unit or system NOTE IF YOU EXPERIENCE A PROBLEM PLEASE CONTACT CUSTOMER SERVICE FIRST OR SEE YOUR WARRANTY DO NOT RETURN THE PRODUCT TO THE...

Page 12: ...anty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual D This warranty does not cover the filters pre filters or other accessories if included except for material or workmanship defects Call us toll free at 1 888 726 8869 or email info sanuvox com Please be sure to specify product name NOTE IF YOU EXPERIENCE A PRO...