6
Instruction Manual for IL COIL CLEAN & ITS VARIOUS MODELS
1-888-726-8869
www.sanuvox.com
STEP 7
STEP 10
STEP 8
STEP 6
STEP 9
7. Slide the two parabolic reflector clamps over the support rod to position
them. Insert the bolts and nuts and tighten everything with a socket
wrench.
8. Rremove the UV Lamp from its packaging. Then, while wearing the
included cotton gloves, carefully “clip” the UV lamp using the metal
spring clips into the parabolic reflector.
NOTE: For ease of use, the end of the lamp with four pins should face the
direction of the ballast box.
9. The IL Coil Clean assembly must be installed with the UV lamp
facing the coil. Rotate the assembly into position and then tighten the
setting screws on each of the mounting flanges.
Recommendations: To ensure you protect users from direct UV
exposure, use a interlok switch on the access door. The switch will
stop the operation of the IL Coil Clean when the door is opened.
10. Installation of the ballast box: Remove the Phillips screws (4) from
the ballast box cover. Set aside the bag containing the Gaynor plug
and lamp boot. Mount the ballast box outside the air handler, on a wall
or other hard surface. Screw it through the 2 holes in the center of the
ballast box.
CAUTION:
Be careful not to damage the wiring.
NOTE:
Depending on the configuration and the number of IL Coil Clean,
there may be one or two ballasts integrated in a single ballast box.
Consequently, you can have one or two 20' teflon cables per ballast.
6. Attach the clamps to the back of the aluminum reflector using Phillips
screws and blocking washers. The parabolic reflector holes are pre-
drilled and pre-threaded.