background image

16

Instruction Manual for BIO-WALL™

1-888-726-8869

www.sanuvox.com

CUSTOMER SERVICE

TO ORDER REPLACEMENT PARTS

PLEASE CONTACT YOUR CONTRACTOR OR SANUVOX CUSTOMER SERVICE

Toll-Free Phone #: 1-888-726-8869

Email: 

[email protected]

Website: www.sanuvox.com

Please be sure to specify product name.
Replacement parts for this product

BST120/277SHS

Ballast with input of 115-277 VAC, 50/60Hz

LMPHGS180

18" T6 High Intensity Germicidal Lamp for BIOM18G

LMPHGS240

24" T6 High Intensity Germicidal Lamp for BIOM24G

LMPHGS300

30" T6 High Intensity Germicidal Lamp for BIOM30G

LMPHGS400

40" T6 High Intensity Germicidal Lamp for BIOM40G

LMPHGS500

50" T6 High Intensity Germicidal Lamp for BIOM50G

LMPHGS600

60" T6 High Intensity Germicidal Lamp for BIOM60G

FLGFIXTUB

Mounting flanges (2)

CON-TUB-19

Clamp assembly (2)

FSTCLP5

Stainless steel spring clamp

TUBAA66

3/4" support rod

BIOSCREEN

BioSmart touch screen for BIO-WALL™

CON-LMP-41

Gaynor Plug

 WARNING

: Use only specified SANUVOX branded replacement UV lamps with your unit or system. 

Use of any other 

lamps will void your warranty and can result in damage to the unit, system and/or lamp(s).

WARRANTY

You should first read all instructions before attempting to use this product.

For this warranty to be valid, keep a copy of the proof of purchase.

UV lamp

2 years

Ballast

15 years

Electronic Components

1 year

A.  This limited warranty applies to repair or replacement of product found to be defective in material or workmanship. This warranty does not apply to 

damage resulting from abusive, unreasonable use or supplemental damage. Defects that are the result of normal wear and tear will not be considered 

manufacturing defects under this warranty.

 

SANUVOX IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE, ANY IMPLIED WARRANTY OF MERCHANTABILITY 

OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY.

 

Some jurisdictions do not allow the exclusion or limitation of incidential or consequential damages or limitation on how long an implied warranty last, so 

the above limitations or exclusions may not apply to you. This warranty gives specific legal rights, and you also may have other rights which vary from 

jurisdiction to jurisdiction. This warranty applies only to the original purchaser of this product from the original date of purchase.

B.  At its option, SANUVOX will repair or replace this product if it is found to be defective in material or workmanship.

C.  This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual.
D.  This warranty does not cover the filters, pre-filters or other accessories (if included), except for material or workmanship defects.

Call us toll-free at 1-888-726-8869 or email: 

[email protected]

Please be sure to specify product name.

NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CUSTOMER SERVICE FIRST OR SEE YOUR WARRANTY. DO NOT RETURN THE PRODUCT 

TO THE ORIGINAL PLACE OF PURCHASE. DO NOT ATTEMPT TO OPEN THE PRODUCT OR TAMPER WITH ITS COMPONENTS WITHOUT CONTACTING 

CUSTOMER SERVICE FIRST. DOING SO MAY VOID YOUR WARRANTY AND CAUSE PERSONAL INJURY OR DAMAGE TO THE PRODUCT.

REGISTER 

YOUR WARRANTY

 

ONLINE AT 

www.sanuvox.com

Summary of Contents for Bio-Wall MAX

Page 1: ... literature tags and labels attached to the UV unit or system and all other safety precautions considered as best practices in the HVAC industry if applicable 9 When applicable local regulation may comprise more restrictive installation and or certification requirements The aforementioned requirements prevail on those of this document and the installer agree to conform to these at his own expense ...

Page 2: ...RATION 11 How to Operate your Product 11 The 3 Operation Modes 11 Step by Step Change of Operation Mode 12 Remote control BMS or limit switch on access door 12 MAINTENANCE 13 How to Replace Lamp s 13 Step by Step Lamp Replacement 13 Step by Step Lamp Timer Reset 14 How to Clean your Product 14 STORAGE 14 ULTRAVIOLETS UVC 14 ELECTRICAL RATINGS POWER CONSUMPTION AVAILABLE VOLTAGE 14 RANGE OF ENVIRON...

Page 3: ...e your specific application please call SANUVOX at 1 888 726 8869 COMPONENTS How it Works The BIO WALL is specifically designed to help reduce biological contaminants such as mold bacteria and viruses that may be circulated through the HVAC system of the building or facility The BIO WALL is installed in the RETURN preferred or SUPPLY plenum of the HVAC system purifying the air passing through the ...

Page 4: ...e sure you have a free and safe space to unpack install and setup your product Confirm you have access to the necessary power source for the product requirements see unit or system label If you have any questions regarding the installation instructions call SANUVOX at 1 888 726 8869 What s included The BIO WALL lamp reflector assembly with 10 cable a ballast box mounting clips 2 support flanges 4 ...

Page 5: ...earby wall but make sure of the distance you only have 3 m of cable between the box and the extrusion NOTE Operating information can be provided in 2 ways via dry contacts that relay data to a BMS or via a BioSmart touch screen optional that can be installed up to 100 feet 32m away 3 Install an access door on the section that will receive the BIO WALL extrusion The size of the access door will be ...

Page 6: ...anges to each end of the pipes and tighten them in place Install 2 Assembled Supports in Duct 8 Knowing the total length of your installation see the table in step 1 attach the pipe furthest downstream in the center of the conduit Screw it in place making sure that the clamp is in the center of the pipe facing you and its opening facing up 9 Attach the 2nd pipe the one closest to your access door ...

Page 7: ...e the ring from the connector and pass the end of the cable through the opening provided in the box between the two fans Secure it in place by putting the ring back in place The rest of the cable should be secured in place with clamps not supplied STEP 16 16 The section of the cable in the box is made up of 20 wires ie 5 wires of 4 strands 2 red and 2 blue Just nearby is a terminal block to which ...

Page 8: ...WALL 19 If you have purchased a BioSmart touch screen now is the time to connect it to your ballast box Follow the instructions provided with the screen NOTE Each BioSmart display has been configured for a specific BIO WALL Be sure to identify the correct one Furthermore if you wish to share the information with a management controller SANUVOX offers 3 BMS operating modes an external 24 VDC power ...

Page 9: ...ELECTRICAL DIAGRAM ...

Page 10: ......

Page 11: ...IO WALL will start automatically when set to Mode 2 VCC signal from L1 will indicate that all lamps are working If the output from L1 is 0V it means that one or more lamps are not working The installer user must supply 0V and VDC 5V to 24V to the PCB NOTE For the BIO WALL to work in Mode 2 it is necessary that 3 wires are connected between the electronic card and the BMS MODE 3 The installer user ...

Page 12: ... above 2 While the mode sequence is displayed you have 5 seconds press the button each time you will change modes 3 When you have selected the desired mode wait 5 seconds for it to be saved Remote control BMS or limit switch on access door A wire jumper is factory installed on the PLC and PLC24 terminals this configuration automatically turns on the lamps when the box is powered If you want to tur...

Page 13: ... Open the duct access door 3 Carefully pull one of the lamps to remove it from the metal clips holding it in place Gently remove the connector from the end of the lamp and pull the lamp out of the conduit NOTE If the connector is damaged do not hesitate to replace it 4 Take a new lamp with your gloved hands insert it into the conduit and plug the connector into it If you have difficulty inserting ...

Page 14: ...el deactivating the contaminants Unlike conventional UV lamps on the market Sanuvox UV units and systems use a patented process designed to deliver the maximum UV dosage to the moving airstream or surface CAUTION Never expose eyes or skin to an operating UV lamp ELECTRICAL RATINGS POWER CONSUMPTION AVAILABLE VOLTAGE The BIO WALL in its largest configuration has a power consumption of up to 775 W e...

Page 15: ...e the UV lamps Replace the ballasts One 1 of the LEDs is RED The lamp or ballast associated with this LED is faulty Replace the UV lamps Replace the ballasts The LEDs flash from RED to GREEN The lamps have passed their 2 years of life Replace the UV lamps The LEDs in the ballast box are off The system is not powered or the power supply is faulty Make sure the system is powered on Replace the power...

Page 16: ...reasonable use or supplemental damage Defects that are the result of normal wear and tear will not be considered manufacturing defects under this warranty SANUVOX IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY Some jurisdictions do...

Reviews: