General characteristic
-
Santec thermostatic valve is suitable for most water heater
systems
provided it is installed correctly
-
Low pressure storage heaters are not recommended for
this application
Cartridggee CClleeaanininngg
After years of use, impurities and lime
scale can restrict the water flow. To clean
the cartridge, please follow these
instructions:
1-
Remove the handle screw, handle trim,
trim plate screws, and
trim
plate.
2-
Shut off the water line by turning the
check valve shut off mechanism clockwise.
Make sure that the both hot and cold sides
are closed.
3-
Remove the cartridge using a 30mm w
rench.
4-
Wash the filter under running water or soak it with vinegar or a descaling agent.
5-
Reassemble the cartridge making sure that the red lines on the cartridge are aligned.
6-
Open the check valve shut-off mechanism, turn on the water, and check water flow.
7-
If the water flow is normal, reassemble the trims..
Note: Cartridge and #17 Temperature
Restrictor have RED markings indicating
the 100° mark should be aligned at the 12
o'clock position.
INSTALLATION INSTRUCTIONS
0
7