6. Regulatory agency
6.1 Safety approvals
This series design shall meet the standards of the following domestic and foreign agencies:
CE LVD: IEC 60950: 1999 3
rd
edition
6.2 EMI/EMS emission approvals
This series design shall meet following EMI/EMS specifications:
FCC Compliance: FCC Rules and Regulations, Part 15, subpart B, Class A.
CE COMPLIANCE: EN55022:1998 class A, EN55024:1998, EN50130-4:1998
EN 61000-3-2:2000, EN 61000-3-3:1995.
7. Reliability
Mean Time Between Failures (MTBF):
MTBF shall be 50,000 hours minimum at 90% confidence level and 100% duty cycle
continuous operation at 25
° C. The calculation shall not include LCD panel.