52
5.2.1.4 Change the Record & Timer Properties
Via the Network
Follow the instructions below to reconfigure the
record and schedule recording settings via the
network.
Set the regular record settings
1. When in the single
–
device mode, click
to enter the SETUP page, (see the sample
screen as in A above)
2. Select a desired recording rate and Quality
from the corresponding drop-down list.
3. Click the
OK
button to proceed.
Set the Alarm record settings
1. When in the single
–
device mode, click
to
enter the SETUP page (see the sample screen
as in A above).
2. Set
Alarm Setting
to
ON
to enable the
drop-down list in the ALARM SETTING
area.
3.Select a desired recording rate and Quality
from the corresponding drop-down list.
4. Click the
OK
button to proceed.
Set the Record Schedule
1. When in the single
–
device mode, click
to enter the SETUP page (see the sample
screen as in B above).
2. Set the
Record Schedule
to
ON
to enable the
Record Schedule
setting area.
3. Click the
Time-Period
button to set the schedule
for recording for each day. Go to both the
Start
Time
&
End Time
boxes, enter a specific
Hour:
Minute
and click
Add
button to add to the
Record List
.
4. When all required settings are completed,
click
OK
to proceed.