F18 SB
Using the machine
36
To activate the AUTOMATIC WASHING of all the
units, see PROGRAMMING, technical user menu,
UNIT WASHING.
Tap for hot water dispensing (5)
6
5
Position a cup of suitable capacity for the desired
water quantity under the tap (5). Press button (6) to
start dispensing hot water from the spout.
The end of dispensing occurs automatically at the
end of the set time. Dispensing can be stopped by
pressing the button (6).
There are two programmable doses: press button
(6) once for dose 1 and twice for dose 2. The
display will show a countdown indicating how many
seconds remain until the end of dispensing.
Hot water temperature control
The machine is equipped with the “mixed water”
function that allows adjusting the water temperature
through the regulator (X) that is located under the
machine. Turn anticlockwise (+) to increase the outlet
water temperature.
X
_
+
Display
During normal operation of the machine the
following screen is displayed:
3
1
2
4, 5, 6, 7, 8
The following information is displayed:
1) current time;
2) temperature/pressure of service boiler (in case of
alarm, they turn red);
3) water level in the boiler;
4) alarm icon;
5) Eco-mode icon enabled;
6) cup heating plate icon enabled;
7) time scheduler activated icon;
8) service icon.