By purchasing the SANlight EVO LED-light you have decided on a high-quality product, which will give you much pleasure. Please
read the operating instructions before using your EVO LED-light, as incorrect use can cause damage to the light or to humans/an-
imals/plants. Failure to use the EVO properly will void any manufacturer‘s warranty and product liability.
Valid for
EVO 3-60, EVO 3-80, EVO 3-100, EVO 4-80, EVO 4-100, EVO 4-120, EVO 5-100, EVO 5-120, EVO 5-150
, EVO 6-120, EVO 6-150
further denoted as
EVO
.
ATTENTION: Photobiological safety note:
According to DIN EN 62471, the EVO LED-module corresponds to risk group “exempt”. These photobiological safety markings are based on testing of the light output characteristic of a single horticultural luminaire. Increased exposure risk to facility personnel may be present depending
upon the number of horticultural luminaires and their placement and/or positioning within the plant growth facility. It is the responsibility of the plant growth facility to address these risks at the facility level and to ensure that people entering the plant growth areas while the lights are on, are
aware of these risks and that appropriate safeguards are in place.
Nevertheless, avoid unnecessarily long irradiation and looking directly into the light source.
Contact manufacturer:
SANlight GmbH,
Montafonerstrasse 14, 6780 Schruns, Austria
, www.sanlight.com, [email protected]
Good luck using your SANlight lamp. For questions, suggestions or further information, please contact your dealer or us.
Distance to illuminated object
The distance between the LED-light (lower edge of the light) and the illumina-
ted surface or the illuminated object must be at least 15cm.
Scope of application of the light
The SANlight EVO LED-light is only suitable for illuminating plants, even in
wet indoor areas.
Permissible ambient temperature for operation
The SANlight EVO LED-light can be operated up to a maximum ambient tem-
perature of 35°C. The minimum ambient temperature at which the SANlight
EVO LED-light can be operated is 5°C.
Permissible ambient conditions for operation
The SANlight EVO LED-light may be operated up to a max. relative humidity
of 90% (non-condensing).
Required accessories for hanging the lamp
No hanging accessories are included in the scope of delivery. The EVO lamp
may only be hung with sufficient load-bearing suspensions. It is recommen-
ded that the lights are suspended from the suspension eyes using steel
carabiners and ropes. (see figures 1, 2 and 3) The suspension must withstand
a permanent load of at least 8 kg.
Permissible orientation of the LED- light
The SANlight EVO LED-light may only be operated in a horizontally suspen-
ded position. In this case, a minimum distance to surrounding objects of
15cm must be observed. In order to guarantee the correct position, the light
must be suspended from both suspension eyelets. (see Figures 1 and 2) The
light may also be suspended via the outer suspension eyelets, in order to
achieve an inclined position of the light. See Figure 3.
Laying the cables
When laying any cables, make sure that they are strain-relieved. Under no
circumstances should cables be subjected to tension. The cables must be
unwound. The EVO light must not be operated with rolled-up cables. Make
sure, that they are not concealed or extended through a wall, floor, ceiling or
other parts of the building. Also do not locate the cables above a suspended
ceiling and make sure that they are not permanently affixed to the building
structure. Note, that they are laid in such a way that they are not exposed to
stress and are protected from physical damage. Cables must also be visible
along their entire length. Notice, that the maximum ambient temperature for
running the EVO LED-light with the cable is 35°C.
Maintenance and Cleaning
To clean the LED-light, use a dust and grease-free cloth. The lamp must
be disconnected from the mains for cleaning. Never use other aids such as
cleaning agents, damp cloths etc. Make sure that the secondary optics of the
LEDs are not scratched by cleaning.
Works and Repairs
Repairs and works may only be carried out by the manufacturer. If repairs,
modifications and other works are not performed by the manufacturer, the
manufacturer‘s warranty and product liability expire.
Upgrade Service
The individual LED-modules can be exchanged by qualified personnel. Please
contact the certified SANlight dealer of trust.
Guarantee Policy
This device has been designed, manufactured and tested in accordance with
the European safety standard (EN60598/CE). The guarantee for the LED-light
and accessories is 3 years from the date of purchase.
The guarantee does not apply to equipment that has not been installed
and maintained as specified in this manual. The manufacturer assumes no
responsibility for damage caused by unauthorized or incorrect use. In case of
damage, the device (LED-light incl. connecting cable) must be returned to the
respective SANlight sales partner, from whom the product was purchased.
They send the defective goods to the manufacturer, SANlight. After repair by
the manufacturer, the device is returned to the respective sales partner.
Hazard warnings
Avertissements de danger
Attention:
The minimum distance to objects in the vicinity of the LED-light is 15cm. The heat sink/housing must not be covered.
La distance minimale aux objets à proximité de la
lumière LED est de 15 cm. Le dissipateur thermique / boîtier ne doit pas être couvert.
Attention:
The SANlight EVO LED-light is only suitable for illuminating plants, even in wet indoor
areas.
La lumière LED EVO ne peut être utilisée que pour éclairer des plantes, même dans des zones intérieures humides.
WARNING:
POSSIBLE RISK OF INJURY TO EYES AND
SKIN: Hazardous optical radiation may be emitted from the light source. Do not stare at operating light source. May be harmful to the eyes. UV may be emitted from the light source.
Eye or skin irritation may result from exposure. Use appropriate shielding. IR may be emitted from the light source. Do not stare at operating light source.
RISQUE DE BLESSURE
POSSIBLE AUX YEUX ET À LA PEAU: Un rayonnement optique dangereux peut être émis par la source lumineuse. Ne regardez pas la source lumineuse quand elle est allumée. Peut
être nocif pour les yeux. La source lumineuse peut émettre des rayons UV. L’exposition peut provoquer une irritation des yeux ou de la peau. Utilisez un écran approprié. La source
lumineuse peut émettre des rayons infrarouges. Ne regardez pas la source lumineuse quand elle est allumée.
Attention:
Do not operate in a potentially explosive atmosphere.
Ne pas
utiliser dans une atmosphère potentiellement explosive.
Attention:
The EVO LED-light may reach temperatures of up to 70°C at the maximum ambient temperature (35°C).
La lampe
LED EVO peut atteindre des températures allant jusqu‘à 70 ° C à la température ambiante maximale (35°C).
Attention:
The LED-light must be sufficiently secured against falling.
La
lumière LED doit être suffisamment sécurisée contre les chutes.
Attention:
If damage to the LED-light or a cable is found, the light must be taken out of service immediately. This must
be done by disconnecting the light from the mains supply.
En cas de dommage à la lumière LED ou à un câble, la lumière doit être immédiatement mise hors service. Cela doit être fait
en déconnectant la lumière de l‘alimentation secteur.
Attention:
To avoid hazards, a damaged outer flexible cable of this light may only be replaced by the manufacturer, their service
representative or a comparable specialist.
Pour éviter tout danger, un câble flexible extérieur endommagé de cette lampe ne peut être remplacé que par le fabricant, son technicien
de maintenance ou un spécialiste comparable.
Attention:
The light source cannot be obtained separately.
La source lumineuse ne peut pas être obtenue séparément.
Attention:
To
protect against injuries, appropriate personal protective equipment (PPE) must be worn when working in the area of the lamp.
Pour vous protéger contre les blessures, vous devez
porter un équipement de protection individuelle (EPI) approprié lorsque vous travaillez dans la zone de la lampe.
Attention:
The models of the EVO-Series are NOT designed for
looping through the mains supply.
Les modèles de la série EVO ne sont PAS conçus pour faire une boucle sur le secteur.
Scope of Delivery
Figure 4 shows all the components of your EVO LED-light. Please check the contents of the packaging for completeness and damage. Never use damaged components. The
mains connection cable is not included and can be ordered separately from your dealer. The scope of delivery includes: 1 x EVO LED-light, Operating instructions.
Installation and Assembly Instructions
Fixing and suspension of the SANlight EVO LED-light: The EVO LED-light can be suspended from the suspension eyelets (see Figures 1, 2 and 3). When suspending the LED-light,
a safety distance of 15 cm to surrounding objects must be observed. Make sure that your suspension is secure and secure the light against accidentally falling.
EVO electrical connection: The EVO LED-light must be connected to the power supply via a separately available SANlight connection cable (see table 1) . It is possible to connect
each light separately or to connect several lights in parallel to each other. For both options SANlight cables must be used.
Electrical connection of one single EVO lamp: To connect each lamp by a separate power cable the following country specific cables can be used. First connect the cable to the
lamp, before connecting to the grid.
Manual
SANlight EVO-Series
1.5
Read before commissioning
Figure 1
Figure 2
Figure 3
Figure 4
Figure 5
Attention: Do not look directly into the light source.
Ne regardez pas
directement dans la source lumineuse.
The LED-light must not be disposed of in household waste! For disposal, the light can be handed back to the manufacturer. The disposal costs are borne by the ma-
nufacturer. Alternatively, the light can be delivered to a disposal company for electrical appliances.
La lampe LED ne doit pas être jetée avec les ordures ménagères!
Pour l‘élimination, la lumière peut être restituée au fabricant. Les coûts d‘élimination sont à la charge du fabricant. Alternativement, la lumière peut être livrée à une
entreprise d‘élimination des appareils électriques.
Attention: The light is not
suitable for covering!
La
lumière n‘est pas adaptée
pour couvrir!
Caution: Risk of shock. Disconnect
power before relamping.
Attention:
Risque d’électrocution. Débrancher
l’alimentation avant de remplacer la
lampe.
Dustproof and jet-proof
luminaire.
Antipoussière
et protégé contre les
jets d‘eau sous tous les
angles.
IP65
The light source of this light may only be replaced by the manufacturer or a service technician
appointed by him or a similarly qualified person.
La source lumineuse de cet éclairage ne peut être
remplacée que par le fabricant ou un technicien de maintenance désigné par lui ou une personne
de qualification similaire.
For connecting more as 7 lamps an inrush current protector has to be used. To connect several lamps to one power socket the following items are needed.
Attention: Connecting several lamps to one power socket must be done by skilled staff. Please contact your certified SANlight trading partner.
Check our website www.sanlight.com for detailed instructions.
For the position of the Tc measuring point see
marking in figure 5.
socket
Euro plug
UK plug
Switzerland plug SEV1011
US plug NEMA 5-15 P
properties
2m, PVC, AWG 16, black
2m, PVC, AWG 16, black
2m, PVC, AWG 16, black
2m, PVC, AWG 16, black
description
Grid power cable EVO-Series EU
Grid power cable EVO-Series UK
Grid power cable EVO-Series CH
Grid power cable EVO-Series US
SANlight article number
AI0037
AI0038
AI0039
AI0040
quantity
1
1 pcs. for 2 lamps
1 pcs. per lamp
description
Grid power cable Q-Series Gen2 2m, PVC, AWG 16, black
H distributon block
Cable extension 1m, PVC, AWG 16, black
SANlight article number
AI0037 / AI0038 / AI0039 / AI0040
AI0018
AI0022
Number of lights per circuit breaker
4 lamps
7 lamps
Powerline fuse protection
Circuit breaker Typ B 230V
Circuit breaker Typ C 230V
400
W
220-240V~ 50/60Hz
5-35°C
20
0W
220-240V~ 50/60Hz
5-35°C
Tec. Specifications EVO
3-60, EVO
3-80 and EVO
3-100
Mains power consumption
Input voltage
Permissible ambient temperature
Tec. Specifications EVO
6-120
and
EVO
6-150
Mains power consumption
Input voltage
Permissible ambient temperature
340
W
220-240V~ 50/60Hz
5-35°C
Technical Specifications EVO
5-100, EVO
5-120 and EVO
5-150
Mains power consumption
Input voltage
Permissible ambient temperature
0,7
3
A (DC)
6
3
W
86V (DC)
105°C
Technical Specifications of a single LED-module
Operating current
Power
Operating voltage
Tc
Connecting several lamps
Depending on the circuit breaker different numbers of EVO
LED-lights can be connected to one power socket. Please check
table 1.
Table 1
265
W
220-240V~ 50/60Hz
5-35°C
Tec. Specifications EVO
4-80, EVO
4-100 and EVO
4-120
Mains power consumption
Input voltage
Permissible ambient temperature