SWL240-12-S
SWL240-24-S
SWL240-36-S
SWL240-48-S
AC100V
2.1
AC240V
1.0
AC100V
AC240V
AC100V
90
AC240V
92
12
24
36
48
15
10
6.7
5.0
0~15.0
0~10
0~6.7
0~5.0
180
240
241.2
240
200
150
170
250
Input-Output
Input-FG
Output-FG
Input-Output
Input-FG
Output-FG
1. Defined by the rating input/output conditions at an environmental temperature of 25℃.
2. Excluding inrush current to noise filter.Also, when the power is turned on again, a current exceeding the indicated value may flow.(Ta=25℃)
3. The output conditions are measured at a point of 15 centimeters from the output connectors
by connecting 100uF electronic capacitors and 0.1uF film capacitors.
4. Ripple noise is measured with a 100MHz oscilloscope using a 1:1 probe (chassis mounted).
5. Voltage regulation includes the result of static input variation, static load variation,warm-up drift and temperature change.
(Transient overshoot, undershoot not specified)
6. Reset is re-input voltage.
7. Insulation conditions are set at room temperature and room temperature.
8. It is a typical value and should be within the rated output power.
9. The output current is a typical value and should be used within the rated output power.
10. AC90V and below requires output delirating.
PAN40012-001E-07
2. Specification Standards
Type
Input Condition
Rated Input Voltage [V]
AC100 ~ 240 1Φ
Input Voltage Variation Range [V] *10
AC85 ~ 265 1Φ(With derating)
Input Current (typ) [A]*1
2.8
1.2
Efficiency(typ) [%] *1
91
94
Inrush Current(typ) [A] *2
15 (AC100V) / 30 (AC200V)
Leakage Current [mA] *1
0.15/0.35max (AC100V/AC240V 60Hz) 0.08/0.19typ (AC100V/AC240V
Rated Frequency [Hz]
50 / 60
Frequency Variation Range [Hz]
47 ~ 63
Power Factor(typ) *1
0.99
0.95
Rated Output Voltage [V]
Output Voltage Variable Range [V] *9
-
Rated Output Current [A] *8
Peak Output Current [A]
-
Output Current Allowable Range [A]
Rated Output Power [W]
Output Condition
*3
Peak Output Power [W]
-
Voltage Regulation [%] *5
±5
Ripple Noise [mVp-p] *1 *4
Hold-up Time(typ) *1
20msec
Start-up time(typ) *1
300msec
Operating humidity range
30-90% (No Condensation)
Storage Humidity Range
20-90% (No Condensation)
Cooling Condition
Natural Air
Additional Function
Over Current Protection
More than 101% of Rated output current (Auto-restart)
Over Voltage Protection *6
More than 115% of rated voltage (output halt: latching halt)
Environmental
Condition
Operating Temperature Range [℃]
-10~+70 (With derating)
Storage Temperature Range [℃]
-25~+85
1 hour each in three directions
Shock[m/s
2
]
196.1 (20G)
Setting Condition
Derating depends on mounting direction
Insulating
Withstand Voltage
AC3000V for 1minutes (Leakage Current : 10mA or less)
AC2000V for 1minutes (Leakage Current : 10mA or less)
AC500V for 1minutes (Leakage Current : 10mA or less)
Vibration
Frequency [Hz]
10~55
Swap Time [Minutes]
3
Acceleration [m/s
2
]
19.6 (2G)
Added Vibration Direction
X,Y,Z
Added Vibration Time
*7
Insulation Resistance
More than 100MΩ
(DC500V)
Input and Output Shape
Connector
Externals Size(W)×(H)×(D) [mm]
160×37×75 (Without Chassis and Cover)
Weight [typ]
350g (Without Chassis and Cover) / 600g (With Chassis and Cover)
Option
Cover
UL62368-1,c-UL(CSA62368-1),SEMKO(EN62368-1),IEC62368-1(CB),
IEC60950-1(CB) certification, compliance with the DENAN Law (J62368-1)
Yes
Mains Harmonic Current
IEC61000-3-2 compliance
Remote ON/OFF Controls
None
Terminal Block
None
Chassis
Yes
Appearance
Structure
・
Standard
Conduction noise
FCC ClassB compliance, EN55032 ClassB compliance,
VCCI ClassB compliance, CISPR32-B compliance
Safety standard
SANKEN ELECTRIC CO.,LTD.
8/26