background image

【Exclusion conditions】

The following cases are excluded from free guarantees.

① Such as inadequate conditions, the environment,

handling of products, and declines and shocks to products,
Use under conditions exceeding the specifications

② Earthquakes, lightning, fire, wind and flood damage, and other natural disasters
③ By modifying, disassembling, and repairing products other than ourselves,

Cases due to reasons other than our responsibilities

④ External factors such as abnormal voltage or other connected equipment

(We shall not be liable for any secondary damage caused by the failure or use of the Product.)
Use within the scope of the above table and five years after our factory shipment

9. Warranty period

8. Expected life

Type

Mounting

Method

Ambient

temperature

Loading factor

75%

100%

Ta=40℃ or less

10 years or more 10 years or more

Ta=35℃ or less

10 years or more 10 years or more

Ta=35℃ or less

10 years or more

5 years

Ta=35℃ or less

10 years or more

6 years

Ta=35℃ or less

10 years or more

4 years

Ta=25℃ or less

10 years or more 10 years or more

Conditions for use of the free warranty range

Ta=50℃ or less

7 years

6 years

Ta=35℃ or less

9 years

8 years

SWL150-**-S

A

Ta=50℃ or less

9 years

5 years

B

Ta=45℃ or less

10 years or more

8 years

C

Ta=40℃ or less

10 years or more 10 years or more

D

Ta=35℃ or less

10 years or more 10 years or more

SWL240-**-S

A

Ta=50℃ or less

10 years or more

7 years

B,C

Ta=40℃ or less

10 years or more

7 years

D

Ta=30℃ or less

10 years or more 10 years or more

E

Ta=25℃ or less

10 years or more

8 years

F

E

Ta=40℃ or less

8 years

3 years

10 years or more

9 years

F

Ta=30℃ or less

10 years or more 10 years or more

E

Ta=35℃ or less

F

Ta=35℃ or less

10 years or more

6 years

Ta=35℃ or less

10 years or more 10 years or more

SWL300-**-S

A

Ta=50℃ or less

9 years

5 years

B

Ta=50℃ or less

10 years or more

6 years

C

Ta=50℃ or less

4 years

2 years

D

Ta=40℃ or less

10 years or more

9 years

SWL100-12

A
B
C
D

E
F

SWL100-

      24,36,48

A
B
C

F

Ta=35℃ or less

10 years or more

6 years

Ta=35℃ or less

10 years or more 10 years or more

D

Ta=35℃ or less

10 years or more 10 years or more

E

Ta=35℃ or less

10 years or more

6 years

SANKEN ELECTRIC CO.,LTD.

24/26

Summary of Contents for SWL Series

Page 1: ...Operation Manual SWL Series PAN40012 001E 07 PAN40012 001E 07 SANKEN ELECTRIC CO LTD 1 26...

Page 2: ...nsional Outline Drawing P 10 4 Model Name Generic Examples Options P 18 5 Terminal Connection P 19 6 Derating P 20 7 Mounting Method P 22 8 Expected life P 24 9 Warranty period P 24 Table of Contents...

Page 3: ...rposes 1 Safety Precautions Safety Requests 5 6 PAN40012 001E 07 Regarding the following applications and equipment that are involved in human health and have a significant impact on the maintenance o...

Page 4: ...ake of safety the product should be handled by anyone with electrical knowledge In this book safety precautions are categorized as danger and caution If the product is used without observing the infor...

Page 5: ...er supply Otherwise an electric shock or fire could occur We do not anticipate the use of this product in equipment that requires high reliability such as those related to human life Do not use for sp...

Page 6: ...C100V AC240V 60Hz 0 06 0 16typ AC100V AC240V Start up time typ 1 700msec Output Condition 3 Peak Output Current A Output Current Allowable Range A Rated Output Power W Peak Output Power W Rated Output...

Page 7: ...V 60Hz 0 05 0 15typ AC100V AC240V Rated Output Voltage V Output Voltage Variable Range V 9 Rated Output Current A 8 Peak Output Current A Output Current Allowable Range A Cooling Condition 300msec Add...

Page 8: ...63 Power Factor typ 1 0 99 0 95 Rated Output Voltage V Output Voltage Variable Range V 9 Rated Output Current A 8 Peak Output Current A Output Current Allowable Range A Rated Output Power W Output Con...

Page 9: ...ciency typ 1 Inrush Current typ A 2 Leakage Current mA 1 Natural Air Additional Function Over Current Protection Over Voltage Protection 6 Environmental Condition Operating Temperature Range Storage T...

Page 10: ...Unit mm The error without instruction is 1 0mm SWL100 S 3 Dimensional Outline Drawing SWL100 L S PAN40012 001E 07 PAN40012 001E 07 SANKEN ELECTRIC CO LTD 10 26...

Page 11: ...Unit mm The error without instruction is 1 0mm SWL100 LC S 3 Dimensional Outline Drawing PAN40012 001E 07 PAN40012 001E 07 SANKEN ELECTRIC CO LTD 11 26...

Page 12: ...Unit mm The error without instruction is 1 0mm SWL150 S 3 Dimensional Outline Drawing SWL150 L S PAN40012 001E 07 PAN40012 001E 07 SANKEN ELECTRIC CO LTD 12 26...

Page 13: ...Unit mm The error without instruction is 1 0mm SWL150 LC S 3 Dimensional Outline Drawing PAN40012 001E 07 PAN40012 001E 07 SANKEN ELECTRIC CO LTD 13 26...

Page 14: ...Unit mm The error without instruction is 1 0mm SWL240 S 3 Dimensional Outline Drawing SWL240 L S PAN40012 001E 07 PAN40012 001E 07 SANKEN ELECTRIC CO LTD 14 26...

Page 15: ...Unit mm The error without instruction is 1 0mm SWL240 LC S 3 Dimensional Outline Drawing PAN40012 001E 07 PAN40012 001E 07 SANKEN ELECTRIC CO LTD 15 26...

Page 16: ...Unit mm The error without instruction is 1 0mm SWL300 S 3 Dimensional Outline Drawing SWL300 L S PAN40012 001E 07 PAN40012 001E 07 SANKEN ELECTRIC CO LTD 16 26...

Page 17: ...Unit mm The error without instruction is 1 0mm SWL300 LC S 3 Dimensional Outline Drawing PAN40012 001E 07 PAN40012 001E 07 SANKEN ELECTRIC CO LTD 17 26...

Page 18: ...tional Equipment Output Power Output Voltage 100 100W No output variable 150 150W 240 240W 100W 150W 240W 12V 24V 36V 48V 4 Model Name Generic Examples Options SWL S Type Standard Products L type Chas...

Page 19: ...VHR 5N SVH 21T P1 1 Input 2 BVH 21T P1 1 3 AC N 4 5 FG 1 V B6P VH VHR 6N SVH 21T P1 1 Output 2 V BVH 21T P1 1 3 V 4 V 5 V 6 V NOTE 2 4 pin of CN101 nothing CN601 should be used at 5 A or less per pin...

Page 20: ...E F SWL100 24 36 48 S PAN40012 001E 07 Output current Load Ambient temperature Reference Derating Curve Without Chassis Cover Ambient temperature Reference Derating Curve Without Chassis Cover 0 20 1...

Page 21: ...e Derating Curve Without Chassis Cover SWL300 S PAN40012 001E 07 0 20 40 60 80 100 10 0 10 20 30 40 50 60 70 0 20 40 10 0 10 20 30 40 50 60 70 Ambient temperature Reference Derating Curve Without Chas...

Page 22: ...001E 07 If a metal case is used secure the dimensions of A and B for the separation between the power supply and the metal case This dimension is the necessary distance for the separation and does no...

Page 23: ...he time of installation Use a small washer W sem screw M3 as the mounting screw Hatching indicates the allowable range for the metal part of the installation on the front side of the chip The size of...

Page 24: ...years or more 4 years Ta 25 or less 10 years or more 10 years or more Conditions for use of the free warranty range Ta 50 or less 7 years 6 years Ta 35 or less 9 years 8 years SWL150 S A Ta 50 or less...

Page 25: ...PAN40012 001E 07 SANKEN ELECTRIC CO LTD 25 26...

Page 26: ...n 530 0001 Japan Phone 81 3 3986 6151 Phone 81 6 6450 4400 Inquiry by E mail sw power sanken ele co jp PAN40012 001E 07 This promotion sheet is as of October 2020 Please note that the contents are sub...