-87-
3201
PID control action selection
Other
than 0
E1001
PID control actions can only work under V/f control or
speed control mode
E1901
Simple energy saving mode cannot be used at the same
time with PID control operation
1
E3203
The same PID control cannot be used internally and
externally at the same time.
2
E3203
The same PID control cannot be used internally and
externally at the same time.
4, 5
E3203
The same PID control cannot be used internally and
externally at the same time.
All
Exxxx
Analog input cannot be repeatedly defined.
3203
Options for external PID
control
1
E3203
The same PID control cannot be used internally and
externally at the same time.
2
E3203
The same PID control cannot be used internally and
externally at the same time.
4, 5
E3203
The same PID control cannot be used internally and
externally at the same time.
All
Exxxx
Analog input cannot be repeatedly defined.
5001
Number of poles, voltage,
capacity of the motor
All
Exxxx
Motors with a capacity too different from that of the
inverter cannot be selected.
Exxxx
The vector control mode is only applicable to motors of 2,
4, 6 poles
E1007
/E1316
/E1317
Exceeding the possible maximum frequency
5011
Primary inductance of the
motor
All
E5013
Mutual inductance of motors cannot be bigger than
primary induction of the motor
5012
Secondary inductance of
the motor
All
E5013
Mutual inductance of motors cannot be bigger than
secondary induction of the motor
5013
Mutual
inductance
of
motors
All
E5011
Mutual inductance of motors cannot be bigger than
primary induction of the motor
E5012
Mutual inductance of motors cannot be bigger than
secondary induction of the motor
6002
Analog value input of
torque
limiter
(power-driven)
All
Exxxx
Analog input cannot be set repeatedly
6004
Analog value input of
torque limiter (braking)
All
Exxxx
Analog input cannot be set repeatedly.
6015
Minimum frequency of the
function of motor vibration
reduction
All
E6016
This value cannot be set above the maximum frequency
of the function of motor vibration reduction.
6016
Maximum frequency of the
function of motor vibration
reduction
All
E6015
This value cannot be set below the minimum frequency of
the function of motor vibration reduction.
6101
Torque command selection
All
Exxxx
Analog input cannot be set repeatedly.
6103
Maximum value of the
forward rotation side of
torque command
All
E6104
This value cannot be set below the minimum value of the
forward rotation side of torque command.
Summary of Contents for LeaderSamco NS
Page 7: ......
Page 8: ...7 1 Safety 1 1 Important notes 1 2 Instructions for use...
Page 9: ...8 1 3 Instructions for installation 1 4 Instructions for transportation and relocation...
Page 10: ...9 1 5 Instructions for wiring...
Page 11: ...10 1 6 Instructions for operation 1 7 Instructions for maintenance and examination...
Page 12: ...11 1 8 Instructions for disposal 1 9 other notes...
Page 22: ...21 4 Connection layout 4 1 Terminal power connection diagram...
Page 24: ...23 4 2 2 Main circuit terminal layout 1 NS 4A003 B NS 4A004 B NS 4A006 B NS 2A003 A NS 2A004 A...
Page 25: ...24 2 NS 4A009 B NS 4A013 B NS 4A017 B...
Page 26: ...25 3 NS 4A024 B NS 4A032 B NS 4A038 B NS 4A046 B...
Page 36: ...35 4 6 Connection to peripheric equipment 4 6 1 Peripheric equipment connection diagram...