7
l
amP
i
nstallation
, r
ePlaCement
or
C
leaning
IN ORDER TO PERFORM THIS TASK, BE SURE TO WEAR THE FOLLOWING SAFETY
EQUIPMENT: SAFETY GLASSES OR A FACE SHIELD, AS WELL AS GLOVES.
Always disconnect power to the fixture before performing any service or maintenance.
Ultraviolet lamp(s) are easily damaged and may cause injury if broken. Exercise care when handling.
1. Disconnect power to the fixture.
2. Open access door, by unlocking the two (2) latches.
Opening of the
SANITAIRE
®
access cover will cause the interlock switch to interrupt power to the
lamps and blower. Do not attempt to bypass or circumvent the interlock switch or its safety feature.
3. Starting from the front, remove each
STER-L-RAY
®
lamp by holding the lamp by the base and carefully pull the lamp away
from the connector, while removing pressure off the
STER-L-RAY
®
lamp from the end supports. (See
Figure 3)
4. Once the lamp is clear from the connector, carefully lift
STER-L-RAY
®
lamp away from the far end support, and remove
STER-L-RAY
®
lamp from the unit. (See
Figure 4
)
5. Repeat until all
STER-L-RAY
®
lamps have been removed from the unit.
Figure 4
Figure 3
6. Moisten a clean, lint-free cloth with denatured alcohol and clean
STER-L-RAY
®
lamps.
7. When
STER-L-RAY
®
lamps have been removed, cleaned, and safely set aside, remove any loose dust or dirt from the
interior of the fixture with a soft dry cloth, or vacuum.
8. To remove any dust, dirt, fingerprints, smears, etc, from the outer surfaces of the
SANITAIRE
®
Room Air Sanitizer,
moisten a clean, lint-free cloth with denatured alcohol and wipe down the unit. Buff out any streaks left from the cleaning,
using a soft dry cloth.