10
OPTIONAL ACCESSORIES
1.
ArmorLite
TM
Lamp Safety Shield:
A protective coating applied to
STER-L-RAY
®
Germicidal Ultraviolet Lamps, ensuring
protection by eliminating the dangers associated with fragments of broken glass and mercury contamination.
2.
Zenith
™
UV-C Detector:
A sensitive, hand-held, self-contained battery operated ultraviolet meter that can be used for:
• Monitoring UV-C Germicidal Lamp Intensity & Aging
• Measuring UV-C Germicidal Fixture Leakage.
3.
Promate
TM
Safety Glasses:
Safety eyewear
MUST
be used as general-purpose safety protection and for additional shielding
from ultraviolet rays.
4.
Promate
TM
Face Shield:
Lightweight visor with adjustable headgear provides eye and face protection from germicidal
ultraviolet rays.
5.
SENTINEL
®
Lamp Operation Indicator:
Monitors individual lamp operation, in any location up to 100 feet from the
SANITAIRE
®
Room Air Sanitizer. Cables are also available in 25, 50, and 100 foot lengths.
For more information and purchasing contact our offices, weekdays between 8:30 am and 5:00 pm Eastern time, at:
Atlantic Ultraviolet Corporation
®
, 375 Marcus Boulevard, Hauppauge, New York, 11788
Tel: 631.273.0500 • Fax: 631.273.0771 • Email: [email protected] • Website: Ultraviolet.com – BuyUltraviolet.com
TROUBLESHOOTING
Always disconnect power to the unit before performing any service or maintenance.
Use personal protection equipment, such long sleeves with no gaps between cuffs and gloves, and
ultraviolet resistant face shield, if troubleshooting
SANITAIRE
®
.
I
MPORTANT:
This unit is to be serviced
ONLY
by qualified, and appropriately trained and/or licensed personnel.
Table 1 – Troubleshooting
Problem
Possible Cause
Corrective Action
Unit not operating.
No electrical power.
Verify that the unit is connected to a live power source.
Power connection to fixture is loose
or disconnected.
Verify power connection to fixture is fully engaged.
Internal blower(s) not
functioning.
Loose power connection.
Confirm connection to blower; connections are tight
and make full contact.
Faulty blower motor.
Replace blower motor.
Two
STER-L-RAY
®
germicidal lamps
not operating
Surelite
TM
Ballast not functioning.
Swap both lamps, with known good lamps.
If good lamps still do not operate, locate
corresponding ballast and replace.
STER-L-RAY
®
Germicidal lamp
not operating.
Swap both lamps, with known good lamps.
STER-L-RAY
®
Germicidal lamp not
properly seated.
Confirm lamps are installed correctly and are seated
making full contact with lamp socket.
All
STER-L-RAY
®
germicidal lamps
not operating.
STER-L-RAY
®
Lamps not installed.
Install lamps.
Interlock switch open.
Confirm access door is closed and latched.
Interlock switch faulty.
Replace interlock switch.
If the above measures fail to correct the problem(s), contact our Application Specialists. Contact options can be found in the
“User Assistance”
section of this manual, located on the back page.