3. Lubricate and assemble the front plate (Fig. 30) in
the following manner:
a. Install the two o-rings on the spigot plunger by
rolling them onto the plunger. Seat the o-rings
in the grooves ensuring that they are not
twisted. Smooth the lubricant into the grooves
and over the sides of the plunger assembly
(Fig. 31).
b. Slide the lubricated spigot plunger into the front
plate ensuring the spigot handle slot is aligned
to the front.
c. Insert the ball end of the spigot handle into the
spigot plunger slot
d. Secure the spigot handle to the front plate with
the faspin and close the spigot by raising up on
the spigot handle.
e. Install the front plate o-ring.
DO NOT LUBRICATE FRONT PLATE O-RING.
4. Secure the front plate assembly with the two
plastic knobs. Simultaneously, turn the knobs in
a clockwise direction. Tighten the knobs evenly.
DO
NOT tighten one knob all the way down and
then the other. This may result in front p
l
ate
breakage. Only moderate force is required. Do
not over tighten
.
5. Install the drip tray and drip tray insert (Fig. 32).
6. Proceed directly to the
"Sanitizing"
section of
this manual.
Fig. 31
Spigot Plunger Lubrication
Fig. 32
Drip Tray Assembly
Spigot Plunger
Faspin
Spigot
Handle
Front Plate
Front Plate O-ring
DO NOT LUBRICATE
Spigot Plunger
O-rings
Front Plate
Knobs
Fig. 30
Front Plate Assembly
(WB7110)
Assembly and Lubrication
(WB7110, cont.)
PAGE 11
ASSEMBLY and LUBRICATION
CAUTION