INTRODUCTION &
4.
Electrical and refrigeration specifications are
located on the data plate on the rear of the individual
machines. Consult local authorities for information
regarding plumbing and electrical codes in the area.
Note: All SaniServ machines should have their
own dedicated circuits whether they are cord
connected plug
-
in devices or hard wired units.
ALWAYS CHECK ELECTRICAL SPECIFlCATIONS
ON THE DATA PLATE OF THE MACHINE. DATA
PLATE SPECIFICATIONS ALWAYS SUPERSEDE
ELECTRICAL INFORMATION IN THIS MANUAL.
5. The water line connections on water
-
cooled
machines are located on the back side of the machine.
The
IN/OUT
lines are clearly marked and have 1/4”
male pipe threads fitted with a 3/4” garden hose fitting.
Note:
These water lines are installed on water
-
cooled
machines only.
FAILURE TO PROVIDE FOR PROPER EARTH
GROUND ACCORDING TO LOCAL ELECTRICAL
CODES COULD RESULT IN SERIOUS ELECTRICAL
SHOCK OR DEATH. DO NOT USE EXTENSION
CORDS. INSTALL THE PROPER SIZE WIRE FOR
THE REQUIRED MACHINE AMPS. BE CERTAIN TO
OBSERVE LOCAL CODES IN SELECTING WIRE OR
CORD SIZE AND TYPE.
DO NOT TURN MACHINE ON
UNTIL THE INSTALLER’S
PRE
-
OPERATIONAL
CHECK SECTION IS
COMPLETE.
Introduction
Installation
WARNING
IMPORTANT
This manual provides a general system description of the SaniServ Frozen Beverage Dispensers. It has been prepared
to assist in the training of personnel on the proper installation, operation, and maintenance of the machines.
Read and fully understand the instructions in this manual before attempting to
install, operate, or perform routine maintenance on the machines.
The following sections of the manual must be performed in sequence:
1. Installation
4. Assembly & Lubrication
2. Installer's Preoperational Check
5. Sanitizing & Operation
3. Disassembly & Cleaning
6. Consistency Adjustment
PAGE 1
ALWAYS USE A SUFFICIENT NUMBER OF PEOPLE
OR MECHANICAL LIFTING EQUIPMENT TO
PROTECT ALL PERSONNEL FROM PERSONAL
INJURY DURING THE REMAINING STEPS.
1. Raise the machine to install the four legs packed in
the mix pan or the four casters packed in a box on the
skid or on the front mounted drip tray.
Be certain all
four are tight! Thread lock is suggested.
2. Carefully lower the machine to the floor and place it
where it will be installed.
3. Level the unit by turning the bottom part of each leg
clockwise or counterclockwise (Fig. 1). The machine
MUST
be level to operate properly.
THESE UNITS
MUST NOT BE
OPERATED
WITHOUT
LEGS INSTALLED OTHERWISE BOTTOM
AIRFLOW TO THE CONDENSER WILL BE
RESTRICTED.
A MINIMUM 6” (152 MM) CLEARANCE MUST
BE MAINTAINED AT THE REAR AND SIDES
OF THE MACHINE FOR ADEQUATE
VENTILATION.
Fig. 1
Minimum
Clearance
4”(102 mm) for
Counter Top
Models and
6”(152 mm) for
Floor Models
WARNING