Consistency Adjustment
Consistency adjustment is done by adjusting the
potentiometer on the electronic control board (ECB).
The ECB is located behind the front wiring box cover
above the front dispensing plate.
1.
Remove two Phillips screws on the underneath
side of the wiring box cover. The ECB is located
on the left side of the wiring box as show in Fig. 30.
2.
Locate
the
black
potentiometer
labeled
HARDNESS
as shown in Fig. 31. By turning the
potentiometer to the right (clockwise) it will
increase the thickness and lower the product
temperature. Turning the potentiometer to the left
(counter clockwise) will decrease the thickness and
raise the temperature.
3.
Reinstall the wiring box cover and reconnect the
power.
4.
Run the unit with product and allow the
refrigeration system to cycle
TWO
times.
5.
Draw product from the machine and check for
desired consistency.
6.
Repeat procedure if required.
NOTE: ONLY TURN THE POTENTIOMETER IN
SMALL INCREAMENTS.
PAGE 13
CONSISTENCY ADJUSTMENT
Fig. 31
Electronic Consistency
Control
CAUTION
BEFORE PROCEEDING
DISCONNECT THE POWER
Electronic Consistency Control
Fig. 30
Wiring Box
Adjustments to the Electronic Consistency Control System should only be made by a certified SaniServ
service technician. DO NOT attempt to make adjustments or repairs on the machine.
This machine is designed with an electronic control board to manufacture
Frozen Slush Beverage On-
ly
!
Do not attempt to operate the machine with soft serve and or shake type products.
Operating
unit with soft serve or shake products will damage the machine and factory warranty will be voided.
DO NOT ADJUST THE MACHINE!
Improper consistency may be due to improperly mixed product
This equipment has been tested at the factory with slush product and has been shipped with FACTORY
PRE
-
SETS. Non
-
Alcoholic beverage temperature will range from 25
-
28 degrees. Alcoholic beverage
temperature will range from 17
-
22 degrees. If you feel a consistency adjustment is needed, check the
temperature of the dispensed product before making an adjustment. If your product is within these tem-
perature ranges and the consistency is incorrect, you may have improperly mixed product.
ADJUSTING THE MACHINE TO COMPENSATE FOR IMPROPERLY MIXED PRODUCT MAY CAUSE
PRE
-
MATURE COMPONENT FAILURE AND MAY VOID WARRANTY.
CAUTION !