16. Removing the Sanipack from the WC suite

Disconnect the electrical power supply.

Turn off  the water feed to the WC cistern. Bail out as much water as possible from the cistern.

Disconnect the discharge pipe.

Disconnect the inlet connections.

Unscrew the 2 fastening screws (on the ground).

Ease the fl exible connector off  the WC pan spigot and slide the Sanipack out from behind the panel.

Note: To ease replacement of the lid onto the Sanipack case, lubricate the rubber seal with liquid soap before replacing.

          Do not reconnect the electrical supply until the re-installation of the unit is complete.

18. Guarantee

2 years guarantee as from its date of purchase subject to correct installation and correct usage.

A

B

C

D

E

F

17. Technical Data

Application

1 WC + washbasin 

Maximum Vertical Pumping

4m

Maximum current consumption

1,8 A

Normal Power Rating

400 W

Electric Class

I

Type

ON01-K70

Degree of protection

IP44

Net Weight

4,8 kg

Voltage

220-240 V

Frequency

50 Hz

 WARNING: Only installations conforming to the above specifi cations are acceptable.

B

C

F

A

D

E

D

 Any replacement of the power supply cable should only be carried out by an authorised SANIFLO service engineer.

DN 20

Summary of Contents for Sanipack

Page 1: ...ng of possible electrical hazard ATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit 2 List of Accessories included A B C D E F G H I x1 x1 x1 x2 x1 x1 x1 x1 x1 Plastic hose clip End cap Adapter Discharge elbow Metal hose clip Metal hose clip Air inlet pipe plus cap Plastic hose clip Rubber Connector Sanipack is a compact pump macera...

Page 2: ...all measurements 4 Performance Curve Height and Length of the discharge pipe Flow Rate litre min Vertical Height Metres 50 60 70 80 90 100 110 120 5 4 3 2 1 0 EN 12050 3 4m 1 3m 2m 1m max 10m max 20m max 30m max 40m max 50m ...

Page 3: ...ible service L 400mm x H 400mm if the side inlets are not utilised L 500mm x H 500mm if the side inlets are utilised Warning A screwdriver or other tool should be required to remove the access panel Please note The SANIFLO range of pumps macerators are fitted with thermal cut out protection In the event of continuous water flow into the unit over a long period E G a tap left running the motor will...

Page 4: ...B and C Cap off unused inlets with plugs D pre grease the joint before fiting Warning When fitting a shower ensure that the underside of the tray is at least 12cm above floor level 8 Connection of a washbasin SILICONE The washbasin can be connected in two ways To one of the side inlets To the inlet on the lid the premarked opening has to be cut out Use a suitable cutter to make the opening in the ...

Page 5: ...rained down before any service work 7 If the discharge pipework runs to a level considerably lower than the unit the resultant siphoning effect can suck out the water seal in the unit Fitting an air admittance valve capable of withstanding 10psi pressure BBA approved at the high point of the pipe run will overcome this problem 8 Ensure all external pipework is adequately lagged to avoid the possib...

Page 6: ...he access panel until all the connections have been checked Warning There should be no dripping of water from the WC cistern or taps If there is this will cause the unit to activate repeatedly as it pumps the water away 13 Usage A WC fitted with a Sanipack does not require any special maintenance The Sanipack will operate automatically as soon as the required level of water enters the case The San...

Page 7: ...e specification or there are too many bends elbows The pump itself is blocked Check the installation Call a service engineer to inspect the motor The motor does not activate The electrical supply is not active Problem with motor or electrical chamber Restore the electrical supply Call a service engineer to inspect the motor The motor emits a rattling or crunching sound A foreign object has entered...

Page 8: ...efore replacing Do not reconnect the electrical supply until the re installation of the unit is complete 18 Guarantee 2 years guarantee as from its date of purchase subject to correct installation and correct usage A B C D E F 17 Technical Data Application 1 WC shower washbasin Maximum Vertical Pumping 4m Maximum current consumption 1 8 A Normal Power Rating 400 W Electric Class I Type ON01 K70 De...

Page 9: ...s 1 16 6a 24 51 57a 57c 57c 57b 38 18 49b 48 49a 14 39 53 43 44 17 42 41a 40a 40b 41b 15 37 30b 31 56 6b 30a 4 5c 5b 5a 55 52 50 54 33 33 22 33 35 8 2a 27 2b 10a 3 13 9 12 19 28a 60 28b 28c 21a 21b 7c 20b 21c ...

Reviews: