background image

Ø 20

Ø 28

Ø 32

OK

OK

9. Connection of the discharge pipework

ø 22

Ø 28

Ø 32

ø 28

Ø 32

ø 32

F

H

G

6

9

22mm
28mm
32mm
40mm

100/110mm

4

1%            

5

Vertical before 
horizontal

7

8

1

 

If required, cut off  the end of the elbow (F) in order to accommodate the appropriate discharge pipe.

2

 

Point the non-return fl ap so that it opens in the direction of fl ow of the discharge pipe.

3

 

Secure the base of the discharge elbow with clip (G) and the discharge pipe end with clip (H).

4

  Horizontal pipe runs must have a minimum fall of 1:100 (10mm per metre) to the soil stack.

5

  If a vertical lift is required, it must be made before the horizontal run at the start of the piperun.

6

  We would recommend that a drain-off  point is installed to allow the discharge pipework to be drained down before any service work.

7

  If the discharge pipework runs to a level considerably lower than the unit, the resultant siphoning eff ect can suck out the water seal in the 

unit. Fitting an air admittance valve capable of withstanding 10psi pressure (BBA approved) at the high point of the pipe run will overcome 
this problem.

8

  Ensure all external pipework is adequately lagged to avoid the possibility of freezing.

9

  The discharge pipework must be connected to the soil stack using an appropriate strap on boss.

N.B. Any elbow on the discharge pipe of the unit will create friction loss (roughly 50cm per elbow to be deducted from the vertical 
pumping specifi cation).

Always use smooth bends (or 2 x 45 degree bends together) and not 90 degree elbows.
Note. The discharge pipework should be copper or rigid solvent weld plastic (22mm or 32mm).

1

2

3

Note: Diagrams 5,6,7 & 8 show the Saniplus and not the Sanipack as an example only.

Air Admittance Valve

Summary of Contents for Sanipack

Page 1: ...ng of possible electrical hazard ATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit 2 List of Accessories included A B C D E F G H I x1 x1 x1 x2 x1 x1 x1 x1 x1 Plastic hose clip End cap Adapter Discharge elbow Metal hose clip Metal hose clip Air inlet pipe plus cap Plastic hose clip Rubber Connector Sanipack is a compact pump macera...

Page 2: ...all measurements 4 Performance Curve Height and Length of the discharge pipe Flow Rate litre min Vertical Height Metres 50 60 70 80 90 100 110 120 5 4 3 2 1 0 EN 12050 3 4m 1 3m 2m 1m max 10m max 20m max 30m max 40m max 50m ...

Page 3: ...ible service L 400mm x H 400mm if the side inlets are not utilised L 500mm x H 500mm if the side inlets are utilised Warning A screwdriver or other tool should be required to remove the access panel Please note The SANIFLO range of pumps macerators are fitted with thermal cut out protection In the event of continuous water flow into the unit over a long period E G a tap left running the motor will...

Page 4: ...B and C Cap off unused inlets with plugs D pre grease the joint before fiting Warning When fitting a shower ensure that the underside of the tray is at least 12cm above floor level 8 Connection of a washbasin SILICONE The washbasin can be connected in two ways To one of the side inlets To the inlet on the lid the premarked opening has to be cut out Use a suitable cutter to make the opening in the ...

Page 5: ...rained down before any service work 7 If the discharge pipework runs to a level considerably lower than the unit the resultant siphoning effect can suck out the water seal in the unit Fitting an air admittance valve capable of withstanding 10psi pressure BBA approved at the high point of the pipe run will overcome this problem 8 Ensure all external pipework is adequately lagged to avoid the possib...

Page 6: ...he access panel until all the connections have been checked Warning There should be no dripping of water from the WC cistern or taps If there is this will cause the unit to activate repeatedly as it pumps the water away 13 Usage A WC fitted with a Sanipack does not require any special maintenance The Sanipack will operate automatically as soon as the required level of water enters the case The San...

Page 7: ...e specification or there are too many bends elbows The pump itself is blocked Check the installation Call a service engineer to inspect the motor The motor does not activate The electrical supply is not active Problem with motor or electrical chamber Restore the electrical supply Call a service engineer to inspect the motor The motor emits a rattling or crunching sound A foreign object has entered...

Page 8: ...efore replacing Do not reconnect the electrical supply until the re installation of the unit is complete 18 Guarantee 2 years guarantee as from its date of purchase subject to correct installation and correct usage A B C D E F 17 Technical Data Application 1 WC shower washbasin Maximum Vertical Pumping 4m Maximum current consumption 1 8 A Normal Power Rating 400 W Electric Class I Type ON01 K70 De...

Page 9: ...s 1 16 6a 24 51 57a 57c 57c 57b 38 18 49b 48 49a 14 39 53 43 44 17 42 41a 40a 40b 41b 15 37 30b 31 56 6b 30a 4 5c 5b 5a 55 52 50 54 33 33 22 33 35 8 2a 27 2b 10a 3 13 9 12 19 28a 60 28b 28c 21a 21b 7c 20b 21c ...