background image

7. Connection of side-inlets (shower and washbasin)

6. Connection to a WC

 The  fl exible sleeve is designed to fi t onto the 100mm WC pan spigot.

Grease the pan spigot with silicon lubricant or liquid soap.

Align the fl exible sleeve with the pan spigot.

Pull the fl exible sleeve over the pan spigot using the two ears projecting from the sleeve.

Warning: If the height of the WC can be adjusted, give a 3% minimum fall to the discharge pipe.

1

2

 To make the connection to the side inlets, use connector (A). Secure it with plastic clips (B) and (C).
• Cap off  unused inlets with plugs (D) (pre-grease the joint before fi ting).

Warning: When fi tting a shower, ensure that the underside of the tray is at least 12cm above fl oor level.

8. Connection of a washbasin

SILIC

ONE

 The washbasin can be connected in two ways.

To one of the side inlets.

To the inlet on the lid (the premarked opening has to be cut out)

• Use a suitable cutter to make the opening in the lid. 

• There is a ridge where the hole has been partially pre-cut. Cut the 

hole with care, and de-burr it, to avoid leaks when adapter  is fi tted.

• Insert the adapter (E) into the lid.

• Slide the washbasin waste pipe into the adapter (it will accept 32mm 

or 40mm pipe).

ø 100

100mm

3%            

min

180mm

ø 40

DN 40

ø 1½

CLOSED

DN 32/40

A

C

B

D

E

D

Summary of Contents for Sanipack

Page 1: ...ng of possible electrical hazard ATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit 2 List of Accessories included A B C D E F G H I x1 x1 x1 x2 x1 x1 x1 x1 x1 Plastic hose clip End cap Adapter Discharge elbow Metal hose clip Metal hose clip Air inlet pipe plus cap Plastic hose clip Rubber Connector Sanipack is a compact pump macera...

Page 2: ...all measurements 4 Performance Curve Height and Length of the discharge pipe Flow Rate litre min Vertical Height Metres 50 60 70 80 90 100 110 120 5 4 3 2 1 0 EN 12050 3 4m 1 3m 2m 1m max 10m max 20m max 30m max 40m max 50m ...

Page 3: ...ible service L 400mm x H 400mm if the side inlets are not utilised L 500mm x H 500mm if the side inlets are utilised Warning A screwdriver or other tool should be required to remove the access panel Please note The SANIFLO range of pumps macerators are fitted with thermal cut out protection In the event of continuous water flow into the unit over a long period E G a tap left running the motor will...

Page 4: ...B and C Cap off unused inlets with plugs D pre grease the joint before fiting Warning When fitting a shower ensure that the underside of the tray is at least 12cm above floor level 8 Connection of a washbasin SILICONE The washbasin can be connected in two ways To one of the side inlets To the inlet on the lid the premarked opening has to be cut out Use a suitable cutter to make the opening in the ...

Page 5: ...rained down before any service work 7 If the discharge pipework runs to a level considerably lower than the unit the resultant siphoning effect can suck out the water seal in the unit Fitting an air admittance valve capable of withstanding 10psi pressure BBA approved at the high point of the pipe run will overcome this problem 8 Ensure all external pipework is adequately lagged to avoid the possib...

Page 6: ...he access panel until all the connections have been checked Warning There should be no dripping of water from the WC cistern or taps If there is this will cause the unit to activate repeatedly as it pumps the water away 13 Usage A WC fitted with a Sanipack does not require any special maintenance The Sanipack will operate automatically as soon as the required level of water enters the case The San...

Page 7: ...e specification or there are too many bends elbows The pump itself is blocked Check the installation Call a service engineer to inspect the motor The motor does not activate The electrical supply is not active Problem with motor or electrical chamber Restore the electrical supply Call a service engineer to inspect the motor The motor emits a rattling or crunching sound A foreign object has entered...

Page 8: ...efore replacing Do not reconnect the electrical supply until the re installation of the unit is complete 18 Guarantee 2 years guarantee as from its date of purchase subject to correct installation and correct usage A B C D E F 17 Technical Data Application 1 WC shower washbasin Maximum Vertical Pumping 4m Maximum current consumption 1 8 A Normal Power Rating 400 W Electric Class I Type ON01 K70 De...

Page 9: ...s 1 16 6a 24 51 57a 57c 57c 57b 38 18 49b 48 49a 14 39 53 43 44 17 42 41a 40a 40b 41b 15 37 30b 31 56 6b 30a 4 5c 5b 5a 55 52 50 54 33 33 22 33 35 8 2a 27 2b 10a 3 13 9 12 19 28a 60 28b 28c 21a 21b 7c 20b 21c ...

Reviews: