background image

Press “stop” button to stop all function.
If the “stop” button is not pressed, the dry function will stop automatically after 3 mins, 
other functions will stop after 60 seconds..

1) Pull the strainer out.

2) Use toothbrush to clean strainer.

3) Install the strainer to original place.

When seated, press “wash/move” button, posterior cleaning nozzle is extended to the right position to 
start the reciprocating self-cleaning. Press “wash/move” button again, nozzle stops moving reciprocatly 
and starts self-cleaning in the fixed position.
While cleaning, press “stop” button to stop cleaning function. If the “stop” button is not pressed, posterior 
function will stop automatically after 60 seconds.
When seated, press “woman/move” button, feminine cleaning nozzle is extended to the right position to 
start the reciprocating self-cleaning. Press “woman/move” button again, nozzle stops moving reciprocatly 
and starts self-cleaning in the fixed position.
While cleaning, press “stop” button to stop feminine function. If the “stop” button is not pressed, feminine 
function will stop automatically after 60 seconds.

When seated, press “wide cleaning” button, cleaning nozzle is extended to start the reciprocating 
wide-cleaning. Press “wide cleaning” button again, nozzle stops moving reciprocatly and starts 
wide-cleaning in the fixed position.
While cleaning, press “stop” button to stop cleaning function. If the “stop” button is not pressed, posterior 
function will stop automatically after 60 seconds.

When seated, press “dry” button to dry cleaning position. Dry function starts working. 
After 3 mins, it will stop automatically.
If you want to continue using, press “dry” button again. Press the “stop” button to stop dry function while 
it is working..

Adjust gear : when using functions of posterior, feminine, wide-cleaning, press “adjust” button to adjust 
“high, middle, low” gear, set the gear and save it at the same time. While using dry function, press “adjust” 
button tu adjust “air temperature” as “high, middle, low”  gear, set the gear and save it at the same time.

While using the functions of posterior, feminine, auto wash, press “massage” button to start massage, 
press “massage” button again, to stop massage. At the same time, the flow of water restores normal 
cleaning mode. Massage flow of water based on “high-low-high” mode starts cycle changes.

Press “auto flush” button to flush toilet.

Press the “nozzle cleaning” button, the nozzle starts self-cleaning automatically. It will stop after 60 
seconds. Press the “nozzle cleaning” button twice, nozzle is extended to do manual cleaning.
If you want to stop nozzle cleaning, press the “stop” button to stop.
(Tip : when start dry function, nozzle cleaning can’t work.)

Press “seat temp” button and adjust seat temperature.

s LIGHT OFF  NORMAL TEMPERATURE
s GREEN LIGHT  LOW TEMPERATURE ­#
s ORANGE LIGHT  MIDDLE TEMPERATURE ­#
s RED LIGHT  HIGHT TEMPERATURE ­#

Press “water temp” button and adjust water temperature.

s LIGHT OFF  NORMAL TEMPERATURE
s GREEN LIGHT  LOW TEMPERATURE ­#
s ORANGE LIGHT  MIDDLE TEMPERATURE ­#
s RED LIGHT  HIGHT TEMPERATURE ­#

Press “light” button, shimmer light makes more convinient to go to toilet in the night.
Press “light” button again to extinguish the shimmer light.

Moving : while using the functions of posterior, feminine, wide-cleaning, press the “front” and “back” 
button, can adjust the cleaning position of front and back.

#,%!. $%/$/2):!4)/. 342!).%2

./::,% #,%!.).'

1) 

Press “nozzle cleaning” button in remote control to start nozzle 

cleaning.

Tip : the bidet has automatically flush function : before and after 
posterior and feminine function.

2) 

Press the “nozzle cleaning” button twice, nozzle is 

extended, can clean by hands.
Use toothbrush to clean nozzle.

3) Press “stop” button to take back nozzle.

WASH

/  MOVE

WOMAN

/  MOVE

Summary of Contents for Excellence

Page 1: ...USER MANUAL EXCE LL ENC E ...

Page 2: ......

Page 3: ...INSTRUCTION SAFETY PRECAUTIONS NAME OF PARTS OPERATING INSTRUCTIONS INSTALLATION INSTRUCTION DAILY MAINTENANCE FAULT RECOGNITION TECHNICAL SPECIFICATIONS WARRANTY CERTIFICATE ...

Page 4: ...the outlet in order to avoid fire risk N 6 Never plug the product on a loos ing electric outlet Please respect all these recommendations to use the SANICLEAN N 1 If your SANICLEAN is not use for a long period please unplug the connection cable and drain the water from the tank N 2 Never install your SANICLEAN where there is direct ray of light It may results a change of the product s color N 3 Vei...

Page 5: ... any flammable mate rials on and close to the SANICLEAN cigarettes N 13 If an invalid person not able to adjust the temperature by itself could use the SANICLEAN please always check that the temperature of water air and seat are always at the level 2 not more This will prevent any trouble du to high temperatures N 14 Never insert or put anything that could obstruct the dryer outlet N 15 Never lift...

Page 6: ...ge protection plug Stainless nozzle Tip please do not cover the infrared receiver otherwise the function will be destroyed Seat cover Warning labels within Operation panel Infrared receiver Infrared receiver Seat Trim Lamp Valve Filter Mp3 interface No function for w660 ...

Page 7: ...ter 60 seconds When seated press wash move button posterior cleaning nozzle is extended to start reciprocating self cleaning Press wash move button again nozzle stops moving reciprocatly and starts self cleaning in the fixed position while cleaning press stop button to stop posterior cleaning function If the stop button is not pressed the posterior cleaning will stop automatically after 60 seconds...

Page 8: ...e using press dry button again Press the stop button to stop dry function while it is working Adjust gear when using functions of posterior feminine wide cleaning press adjust button to adjust high middle low gear set the gear and save it at the same time While using dry function press adjust button tu adjust air temperature as high middle low gear set the gear and save it at the same time While u...

Page 9: ...r to sit a right position and reduce to waste cleaning water Quick instruction 1 Cleaning position Quick instruction 2 Massage cleaning Quick instruction 3 Fixed position cleaning Choose the button to use Choose the button to use 1 2 3 1 2 3 1 2 3 INSTALLATION INSTRUCTION 1 INSTALL UPPER AND LOWER BODY 1 Connect inlet water interface to inlet water valve and screw up through the other side of inle...

Page 10: ...nchoring 3 BIDET INSTALLING The seal must be perfect when installing the pipe because of the syphonic flushing system that can only operates with 100 Airproof a b Flange ring installing Flange ring Evacuation Pipe Main unit Main unit Evacuation pipe installation The seal must be perfect to operate the flush Without perfect seal flushing of the device will not work correctly Main unit Flange ring F...

Page 11: ...r to rotate right to reduce water pressure 3 Open your network water and the water valve to supply water to the main unit 4 TURN ON THE POWER OF BIDET 1 Thrust protective leakage valve to socket of 220V 50HZ and make sure grounding type receptacle 2 Try to test if every functions are normal 3 Clean foreign matter when finish installing Toilet evacuation 185 mm BE CAREFUL The pressure of your exist...

Page 12: ...ug and restart button again to confirm if the lamp turns off 2 CLEANING STRAINER Please have to check strainer Once or twice one month 1 Use screw driver turn off sluice valve stop water comes in 3 Clean sewage of strainer 2 Revolve strainer the right side 4 Install strainer again and screw up 5 Use screw driver open valve and make sure if the strainer is leakage ...

Page 13: ...ress nozzle cleaning button in remote control to start nozzle cleaning Tip the bidet has automatically flush function before and after posterior and feminine function 2 Press the nozzle cleaning button twice nozzle is extended can clean by hands Use toothbrush to clean nozzle 3 Press stop button to take back nozzle ...

Page 14: ...ain unit 2 Never use aggressive product or any detergent to clean the main unit 3 When you clean the floor around the main unit avoid splashing water on the main unit to protect it 4 Check that the Remote control receiver on the main unit is always clean to avoid connection problem between the main unit and the remote control WARNING ...

Page 15: ...alve to flex If the nozzle is blocked up by foreign matter Clean nozzle read page 10 If inlet water valve is flexed or blocked up Remove inlet water valve to flex Plug off and plug in alimentation If water temperature is setted as low gear or normal gear According to instruction to adjust water temperature read page 5 If seat temperature is setted as low gear or normal gear According to instructio...

Page 16: ...nlet Direct inlet flow type Water home supply Needed water pressure mini 0 4 bars maxi 7 bars Quantity water minute Wash Max 0 7 litre min Woman Max 0 7 litre min Water tank capacity 6 litres Washing temperature Up to 40 C level 4 Heated seat Up to 40 C level 4 Drying Up to 60 C level 4 Deodorisation catalyst deodorising system User detection sensor Digital sensor Water proof grade IPX4 Safety dev...

Page 17: ...ufacturing The warranty is not valid for parts damaged by the user or by installation non conform to SANICLEAN SAS recommendations for instance If the product as been disassemble or repair by non official technician from SANICLEAN SAS The installation is not conforming to SANICLEAN recommendation The use is not conforming to SANICLEAN precaution of use The connection has been done on a non conform...

Page 18: ...WITH OTHER HOUSEHOLD WASTES AT THIS END OF ITS WORKING LIFE IN ORDER TO BE RECYCLE PLEASE BRING YOUR PRODUCT IN A CERTIFIED DECHETTERY YOU CAN CONTACT ANY SANICLEAN DEALER TO STUDY THE WAY TO ELIMI NATE YOUR OLD SANICLEAN www saniclean fr ...

Page 19: ......

Page 20: ...www saniclean fr ...

Reviews: