RECEIVER WIRING
1. Neutral
2. Live
3. Output (Call for heat) - Normally closed
4. Input (Switching circuit)
5. Not used - Normally open
Externally link 2 to 4 if using a single 230Vac supply
RF ADDRESS CODE SETTING
The thermostat and receiver are automatically paired when you
receive them, however, if there is another unit nearby (e.g. in a
neighbours home) the receiver may trigger their transmitter.
To avoid this you can change the RF address code on both the
thermostat and transmitter. To do this open up both and change
the DIP-switches inside each. Both must match each other in
order to communicate.
FITTING THE TABLE STAND
FLATHEAD
SCREWDRIVER
EXAMPLE CIRCUIT DIAGRAMS
NB: For reasons of space & clarity some system components are not shown.
230V
230V
230V
230V
COMBI
Externally link 2 to 4 if using a
single 230Vac supply
COMBI
Switched supply taken
from boiler
2-PORT MOTORISED VALVE
Spring return
3-PORT MID POSITION
MOTORISED VALVE
Spring return
VALVE
VALVE
W GY