background image

COPY/PASTE DAY

To speed up the programming sequence you can copy 

one day into another, or several other, days.

1.  Press 

Set

 x2

 

to enter copy mode.

2.  Choose the ‘Copy’ day using 

 and press 

Ok

.

3.  Choose the ‘Paste’ day using 

 and press 

Ok

.

4.  Repeat step as required for further ‘Paste’ days

At any point Press 

Ok

 x2 to return to Run Mode

RESET UNIT

To erase all current setti  ngs and return to it’s factory 

default setti  ngs & programs.

1.  Press and hold 

Ok

 and 

 for 6 seconds.

2.  When Reset is displayed push in the 

Reset

 butt on.

3.  All segments on the display are shown to confi rm 

reset has taken place.

PROGRAMMING

Within programming mode the thermostat will return 

to normal operati on if no butt ons are pressed for 30 

seconds.

To exit programming mode either wait 30 seconds or 

press 

Set

 x2 and 

Ok

.

NB: Each day’s end ti me is 11:59 in 12hr or 23:59 in 24hr 

formats. P6 should never be set for midnight as this will 

cause an error in programming.

Each day of the week can be programmed separately, 

starti ng with Monday (Mo)

1.  Press 

Set 

to enter programming mode.

2.  Set Mo MORN temperature using 

▼▲

 and press 

Ok

.

3.  Set Mo MORN ti me using 

▼▲ 

and press 

Ok

.

4.  Set Mo DAY temperature using 

▼▲

 and press 

Ok

.

5.  Set Mo DAY ti me using 

▼▲

 and press 

Ok

.

6.  Repeat procedure for all 6 set points in the day and 

conti nue on to program each day of the week.

At any point Press 

Set x2

 then 

Ok

 to return to Run Mode

MORN

DAY

Noon Break

EVEN

NIGHT

NIGHT

CUSTOM PROGRAM cont...

Below shows the programming segments of the default program on a Weekday.

Held over from previous 

day’s setting

.

Essenti ally, if the thermostat reads the temperature below the chosen temperature it will 
send a message for the boiler to fi re and your heati ng to come on. 

The above diagram shows how the day is split up into named parts but BOTH the ti mes 
and temperatures are changeable. Using the programming instructi ons that follow you 
can set the ti me each part starts and the temperature it will set to at that point. As can be 
seen the NIGHT setti  ng carries over & stays unti l the MORN ti me the following day.

If you don’t need a certain program to be there, for example you do not require Noon as 
no one is home at that ti me of the day, then you simply set that program for the same 
temperature as the one before - as it cannot be deleted. There must be 6 programmed 
events each day even if they are set to the same temperature.

Mo - Fr

Time

°C

1: MORN

2: DAY

3: Noon
4: Break
5: EVEN

6: NIGHT

Sa - Su

Time

°C

1: MORN

2: DAY

3: Noon
4: Break
5: EVEN

6: NIGHT

CREATING YOUR PROGRAM

Use the grids below to plan out your own custom program before you start.

2am

6am

10am

2pm

6pm

10pm

6:00am 8:30am

12:00pm 2:00pm 4:30pm

10:30pm

Prog

 is shown at the 

top of the display

Copy Prog

 is shown at 

the top of the display

Summary of Contents for RSTAT5 RF

Page 1: ...ale 0 5 C Temperature display range 0 to 50 C Temperature display scale 0 1 C Operating temperature 0 to 50 C Switching differential 0 5 C or 1 0 C selectable Clock accuracy 1 sec per day Protection rating IP30 Pollution class 3 Flexible wire size 0 5 1 5mm2 Rigid wire size 0 5 2 5mm2 Dimensions L110 8 x H104 x D21 5 Transmission frequency 868 35Mhz ErP Class I RECEIVER Power supply 230Vac 50Hz Co...

Page 2: ...ansmitter To avoid this you can change the RF address code on both the thermostat and transmitter To do this open up both and change the DIP switches inside each Both must match each other in order to communicate FITTING THE TABLE STAND FLATHEAD SCREWDRIVER EXAMPLE CIRCUIT DIAGRAMS NB For reasons of space clarity some system components are not shown 230V 230V 230V 230V COMBI Externally link 2 to 4...

Page 3: ...re and then tell the boiler to turn off meaning you won t be calling for heat when your home is already at your desired temperature When you set a temperature you are saying you don t want the heating to come on unless the room temperature is lower than the set temperature CHANGING THE BATTERIES When the Battery Low warning sign appears on the display replace the batteries immediately Flip to open...

Page 4: ...elect the Month and Year using and press Ok 3 Select the Day using and press Ok 4 Hold Temp Until Temp Set Hours are displayed To cancel setting and return to normal operation press Ok Set Temp 0 5 C 1 0 C 0 5 C 1 0 C Boiler ON Boiler ON Boiler ON Boiler OFF Boiler OFF Boiler OFF SETTING THE TIME AND DATE Before you set the thermostat you should fix the time and date 1 Press and hold Set for 6 sec...

Page 5: ...uld be lowered cooler temperatures help you sleep What temperature should I heat my home to Turning your room temperature down just one degree can have significant savings on your energy bill A good way to get the right temperature for you is to start at 21 C leave it for a week and lower 1 C Repeat this process until you notice it being a little too cool and turn it back up 1 C You now have the l...

Page 6: ... and continue on to program each day of the week At any point Press Set x2 then Ok to return to Run Mode MORN DAY Noon Break EVEN NIGHT NIGHT CUSTOM PROGRAM cont Below shows the programming segments of the default program on a Weekday Held over from previous day s setting Essentially if the thermostat reads the temperature below the chosen temperature it will send a message for the boiler to fire ...

Reviews: