KBox C-103-CFL-x - User Guide, Rev. 1.0
// 64
8.1.
Specifications of the internal M.2 Connectors
Table 14: Specifications of the internal M.2 Connectors
M.2 Connector No.
J13
J17
J18
M.2 Connector type
B-Type
M-Type
B-Type
PCIe lanes/ Gen
X1 / G3
X4 /G3
X1 / G3
SATA
no
no
yes
1
USB
2.0
no
2.0
MicroSIM
yes
no
no
Mech. Format
2230
yes
no
no
3030
yes
no
no
2242
yes
yes
yes
3042
yes
no²
no²
2260
no
yes
yes
2280
no
yes
yes
yes
1
: muxed with SATA0/J24
no
2
: possible
8.2.
Control Cabinet Mounting
Expansion card installation should be performed before installing the KBox C-103-CFL into
the control cabinet.
Please observe the “General Safety Instructions for IT Equipment” (included) and the
installation instructions (refer to the chapters 1/ and 8/).
Your KBox C-103-CFL is supplied with assembled mounting brackets. The key holes of the upper and lower mounting
brackets (Figure 25, pos. 1 and pos. 3) allow you to mount the KBox C-103-CFL to a mounting side of the control
cabinet in vertical position. This is the only permitted operating position.
For a sufficient air circulation around the device, we recommend not to place (mount) or
operate any other devices within the “keep out area”. The clearances of “50mm” and
“100mm” around the KBox C-103-CFL must be observed; refer to the marked areas in Figure
46 to Figure 52.
Prepare the mounting surface with four screws and if necessary anchors corresponding to the mounting surface type
(fire-resistant material). Please refer to the information for mounting to the section 12.1, “Mechanical Specifications
of the KBox C-103-CFL”, and the subsections 12.1.1 / 12.1.4 / 12.1.5 / 12.1.6 and 12.1.7, or refer to the drawings for
KBox C-103-CFL on our web site. The drawings can be downloaded from our web site www.kontron.com by selecting
the product.