KBox C-103-CFL-x - User Guide, Rev. 1.0
// 46
5.10.
Optional Versions with Fan Tray - KBox C-103-CFL-4/-2/-1
By using a fan tray, the KBox C-103-CFL-4/-2/-1 can be operated in a control cabinet with extended ambient
temperature; refer to the specified values in the section 12.2 “Environmental Specifications” and chapter 7/ “Thermal
Considerations”.
All chapters of this manual are valid for the KBox C-103-CFL-4, the KBox C-103-CFL-2 and
KBox C-103-CFL-1 with fan tray under consideration of the mechanical differences and the
description in this section. Please refer also to the subsection 12.1.2 “Mechanical
Specifications of the KBox C-103-CFL-4 with Fan Tray Option”, subsection 12.1.4 “Mechanical
Specifications of the KBox C-103-CFL-2 with Fan Tray Option”, and subsection 12.1.6
“Mechanical Specifications of the KBox C-103-CFL-1 with Fan Tray Option”.
The KBox C-103-CFL with fan tray chassis extension is designed to provide a better airflow through the system
chassis. The KBox C-103-CFL-4/-2/-1 can be only factory equipped with the optional fan tray (Figure 32). The fan tray
slot is external mounted to the bottom side of the KBox C-103-CFL-4/-2/-1 chassis and comprises a fan tray (Figure
32, pos. 1) with one fan as well as the air filter.
Figure 32: KBox C-103-CFL-1 equipped with the optional fan tray
The fan is integrated in a user-friendly, replaceable fan tray (hot-swapping). The fan tray is designed to be inserted
into the fan tray slot (Figure 32, pos. 6) on the bottom side of the KBox C-103-CFL-4/-2/-1. The fan tray simplifies the
installation and removal of this component, even during operation.
The fan rotation speed is temperature controlled in dependence on the CPU temperature. Thus, a reliable air
circulation for optimal active cooling of the KBox C-103-CFL-4/-2/-1 is ensured.
The temperature conditions of the system (depending on the environmental temperature and the system load) are
detected by the CPU temperature sensor.
In order to ensure a clean air circulation through the system, the fan tray slot provides an installed
air filter (Figure 32, pos. 3).
The air filter, which protects your system against dust and dirt, is washable and may be replaced during operation;
refer to subsection 10.4 “Cleaning the Air Filter”.
4
1 Fan tray with knurled screws
2 Air filter holder with knurled screws
3 Air filter
4 Functional earth stud
5 Lower mounting bracket with key holes
6 Fan tray slot with installed fan tray
7 KBox C-103-CFL-1 variant with optional fan
tray
8 Upper mounting bracket with key holes
2
3
1
5
8
7
6