Alarm Set Points 

 

An audible buzzer will sound if the buzzer switch on the circuit board is on!  

 

CO

2

 alarm levels stated are factory set condition only! 

 

Target Gas 

Pre-Alarm

 

Buzzer

 

Alarm

 

Buzzer

 

Methane/Natural Gas (NG) 

 8% LEL 

No Sound 

▲ 

10% LEL 

Continuous 

sound 

Liquid Petroleum Gas (LPG) 

 8% LEL 

 10% LEL 

Hydrogen Gas (H

2

 8% LEL 

 10% LEL 

Oxygen (O

2

19.5% 

 

18.5% or 

23%  

Carbon Monoxide (CO) 

▲ 

20 ppm 

▲ 

20ppm after two (2) hours  

 50ppm

 after 

One (1) hour 

 100ppm

 after 

Ten (10) minutes  

▲ 

300ppm after One (1) minute  

*Carbon Dioxide (CO

2

 800 ppm 

 1000 ppm 

3 beeps every 

10 seconds 

 

▲ 

Rising alarm 

▼ 

Falling alarm  

(LEL) Lower Explosive Limit (PPM) Parts Per Million 
* CO

2

 alarm levels stated are factory set condition only. 

 

Maintenance 

Cleaning 

 

Concentrations of alcohol found in many products may damage, deteriorate or affect the gas sensing elements such as; 
wine; deodorants; stain removers and thinners. Other gases and substances to avoid are corrosives (i.e., chlorine & 
hydrogen chloride); alkali metals; basic or acidic compounds; silicones; tetraethyl lead; halogens and halogenated 
compounds!  

 
Keep your gas detector in good working order - follow these basic principles. 

 

Remove any dust/debris from the outer enclosure regularly using a slightly damp cloth. 

 

Never use detergents or solvents to clean your device. 

 

Never spray air fresheners, hair spray, paint or other aerosols near the device. 

 

Never paint the device. Paint will seal vents and interfere with the device. 

 

Manual Circuit Simulation Test 

 

Access to the interior of the detector, when carrying out any work, must be conducted by a competent person!  

 

This circuit test does not check the gas-sensing element itself!  

When the test button on the circuit board is pressed and held for ~3seconds the detector will simulate an open circuit 
to ensure configured systems, outputs, alarms, indications, and other external devices operate as intended in 
response to gas. The test sequence will automatically terminate after a short period of time and return to normal 
operation.  
 

Bump Test (Gas Response Check) 

 
What is a Bump Test?  

Gas r

esponse checks are often referred to as a ‘

bump test

’. Bump tests are important to make sure a device 

can 

detect a release of gas as early as possible. The aim of the bump test is to make sure a detector is working at its 
optimum by briefly exposing the unit to a known concentration of the target gas that usually exceeds the highest 
alarm point. If the detector goes into alarm and all signals/outputs activate, then the system is working safely.  
If the system fails to operate as intended in an alarm state, the gas detector must not be used until a full inspection 
and service has been conducted.  

Summary of Contents for Merlin Detector i-S

Page 1: ...170322 1 Merlin Gas Detector i S Installation Operation Maintenance Please read this manual carefully and retain for future use For specific requirements that may deviate from the information in this...

Page 2: ...Power Input 6 Wiring Alarm Relays 7 Alarm Relay Setting Switch Latch On Off 7 Wiring 0 10V Analogue Output 7 CO2 Selection Switches 7 Audible Buzzer Switch 8 Factory Set Condition 8 Operation 8 Initia...

Page 3: ...nufacturer s Warranty Warranty coverage The manufacturer warrants to the original consumer purchaser that this product will be free of defects in material and workmanship for a period of three 3 years...

Page 4: ...is also relevant to toxic gas detection Recommended heights may vary based on air flow and temperature conditions in addition to the proposed application and location Locations for detectors will var...

Page 5: ...wo gang electrical box Restrain the hazardous live wiring from accidental loosening to prevent wires from moving after installation and touching parts of opposite polarity or at low voltages Isolate t...

Page 6: ...d any warranty Wiring Power Input Standalone Power 12 24V power inputs can be either AC or DC Terminals are pluggable type to ease connections Merlin GDP Power Connection Power is supplied via the GDP...

Page 7: ...a red dot on the screen when the alarm relay has latched The alarm will beep every 10 seconds to alert the user that the detector entered an alarm state To reset the Detector press and hold the touch...

Page 8: ...tors are shipped pre calibrated and configured Buzzer On Off Switch On Alarm Relay Setting Switch On CO2 Selection Pre Alarm 800ppm Alarm 1000ppm 0 2000ppm 0 10V Output Range Operation Initial Power U...

Page 9: ...rly using a slightly damp cloth Never use detergents or solvents to clean your device Never spray air fresheners hair spray paint or other aerosols near the device Never paint the device Paint will se...

Page 10: ...uld always be given to any applicable national local law and industry codes Generally the gas concentration should be greater than the alarm threshold of the device Always remove the regulator valve a...

Page 11: ...Evaluated Operating 10 50 C 20 90 RH non condensing Storage 0 50 C 30 80 RH no condensation Altitude Rating 2000m Wiring Typical Min 2 5mm2 75 C min Tinned copper Approvals Electrical Safety and Elec...

Page 12: ...om any unforeseen damage caused by transit installation Every effort is made to ensure the accuracy of this document however S S Northern can assume no responsibility for any errors or omissions in th...

Reviews: