Guide
use and  installation

Please  read  these  installation  and  use  instructions
carefully  and  keep  them  for  future  reference.  The
manufacturer  reserves  the  right  to  introduce  all  the
technical and constructive changes  it deems necessar

EN  50194

CEI  216-3

EN  50270

Di  Installazione    EN  60079-29-2

Report  rilasciati  da  TUV  Italia

The appliance assembly / maintenance operations must be carried out in the absence of mains voltage.

Household Methane or LPG gas detector  RGX100

2

BUILT ACCORDING TO REGULATIONS EN 50194-1 - EN 50270

  Belonging  to

The elegance and the prestige, that have always made BEINAT S.r.l stand out from its competitors, together with the
concept  of  home  fitness  comes  the  household  gas  detector  RGX100

2

  detects  through  the  catalytic sensor  ,  the

presence of explosive gas such as: Methane or LPG.

Gas detection

The detector is tested and calibrated to  10% of L.E.L.

Through the built-in relay, the RGX100

2

 can activate: solenoid valves, sirens, and any other device alarm.

A series of technical features make this gas detector extremely versatile, reliable, accurate, and safe.
through  an  internal  jumper it is possible  to select the  relay  impulse functioning,  to  connect  manual  reset  solenoid
valves, or the continuous functioning, to activate class “A” solenoid valves and sirens.
The  relay,  free  of  voltage,  allows  installation  of  multiple  detectors  on  a  single  solenoid  valve  ensuring  control  of
multiple dangerous environments.

The detector is complete with a special circuit that controls the catalytic sensor’s efficiency level, and signals
any possible fault.
The enclosure with IP42 degree of protection can be installed either on the wall or on a 503 flush-mounted box.

Important: Assembly / maintenance of the appliance must be carried out by qualified personnel and in
accordance with applicable laws and regulations.
The manufacturer assumes no responsibility for the use of products that have to comply with particular
environmental and / or installation standards.

Important note
Before connecting the equipment, it is recommended that you read the instruction manual carefully and
keep it for future reference. It is also recommended to perform the electrical connections correctly as
per enclosed drawings, observing the instructions and the Standards.
N.B. Refer to the documentation in all cases where the symbol is on the side

Channel:  Beinat  gas  solutions

Electric connections also available on

TO  PROTECT  YOUR  FAMILY

Summary of Contents for RGX1002

Page 1: ...jumper it is possible to select the relay impulse functioning to connect manual reset solenoid valves or the continuous functioning to activate class A solenoid valves and sirens The relay free of voltage allows installation of multiple detectors on a single solenoid valve ensuring control of multiple dangerous environments The detector is complete with a special circuit that controls the catalyti...

Page 2: ...or falls during transportation or installation can damage the appliance Avoid abrupt temperature fluctuations Sudden temperature variations can cause condensation and the probe could work poorly Cleaning Never clean the device with chemical products If necessary wash with a moist cloth Absolutely avoid using any cloth dipped in thinners alcohol and chemical detergents Disposal of the device Concer...

Page 3: ...e installation of the detector does not exempt from The compliance with all regulations concerning the characteristics installation and use of gas appliances The ventilation of the spaces and the elimination of combustion products are described in the UNI norms according to ART 3 LAW 1083 71 and relevant legal provisions 1 2 3 4 5 Pass cables ...

Page 4: ...us functioning 6 Catalytic sensor for Methane or LPG explosive gas detection 7 Identification label registration number and manufacturing year located under the ABS small dome Components and commands 1 Put out all free flames 2 Close the main gas tap or the LPG cylinder tap 3 Do not turn any lights on or off do not turn on any electrical device or appliance 4 Open windows and doors in order to inc...

Page 5: ...ps below 10 C or rises above 40 C The detector is equipped to detect different types of gases and according to these its must to be positioned at different heights These heights are 30 cm from the lowest point of the floor in order to detect heavy gases LPG etc 30 cm from the highest point of the ceiling in order to detect light gase Methane etc Install detectors from 1 to 4 m from gas appliances ...

Page 6: ...Solenoid valve NC N Power Supply 230 VAC Ph N C C NO 1 2 3 4 5 Solenoid valve NO WARNING Before connecting to the mains power ensure the voltage is correct Carefully follow the instructions and the connections according to Regulations in force An automatic disconnetting switch appropriately identified as the detector sectioning device must be incorporated in the electrical system suitably located ...

Page 7: ...ed FAULT in this case proceed with the inspection of the capsule detector If the detector goes into alarm and closes the connected equipment Check that connections are correct and that the jumper which leads to the common voltage of the relay has been carried out all the relays are voltage free Check the scheme of connection If RGX1002 is connected to a Solenoid valves 12V cc and does not work To ...

Page 8: ...direct or indirect to people animals or things from product faults and from its enforced suspension of use DISPOSAL OF OLD ELECTRICAL ELECTRONIC EQUIPMENT This symbol on the product or its packaging to indicates that this product shall not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment such a...

Reviews: