background image

hdf2dl6sm-rev0817

sandpiperpump

.

com

Model HDF2/HDF50 • 

6

Recommended Installation Guide

Troubleshooting Guide

For additional troubleshooting tips contact After Sales Support at [email protected] or 419-524-8388

Symptom:

Potential Cause(s):

Recommendation(s):

Pump Cycles Once

Deadhead (system pressure meets or exceeds air 

supply pressure).

Increase the inlet air pressure to the pump. Pump is designed for 1:1 pressure ratio at zero flow. 

 

(Does not apply to high pressure 2:1 units).

Air valve or intermediate gaskets installed incorrectly. Install gaskets with holes properly aligned.

Bent or missing actuator plunger.

Remove pilot valve and inspect actuator plungers.

Pump Will Not Operate 

/ Cycle

Pump is over lubricated.

Set lubricator on lowest possible setting or remove. Units are designed for lube free operation.

Lack of air (line size, PSI, CFM).

Check the air line size and length, compressor capacity (HP vs. cfm required).

Check air distribution system.

Disassemble and inspect main air distribution valve, pilot valve and pilot valve actuators. 

Discharge line is blocked or clogged manifolds.

Check for inadvertently closed discharge line valves. Clean discharge manifolds/piping.

Deadhead (system pressure meets or exceeds air 

supply pressure).

Increase the inlet air pressure to the pump. Pump is designed for 1:1 pressure ratio at zero flow. 

 

(Does not apply to high pressure 2:1 units).

Blocked air exhaust muffler.

Remove muffler screen, clean or de-ice, and re-install. 

Pumped fluid in air exhaust muffler.

Disassemble pump chambers. Inspect for diaphragm rupture or loose diaphragm plate assembly. 

Pump chamber is blocked.

Disassemble and inspect wetted chambers. Remove or flush any obstructions. 

Pump Cycles and Will 

Not Prime or No Flow

Cavitation on suction side.

Check suction condition (move pump closer to product).

Check valve obstructed. Valve ball(s) not seating 

properly or sticking.

Disassemble the wet end of the pump and manually dislodge obstruction in the check valve pocket.  

Clean out around valve ball cage and valve seat area. Replace valve ball or valve seat if damaged. 

Use heavier valve ball material.

Valve ball(s) missing (pushed into chamber or 

manifold).

Worn valve ball or valve seat. Worn fingers in valve ball cage (replace part). Check Chemical 

 

Resistance Guide for compatibility.

Valve ball(s) / seat(s) damaged or attacked by product.

Check Chemical Resistance Guide for compatibility.

Check valve and/or seat is worn or needs adjusting.

Inspect check valves and seats for wear and proper setting. Replace if necessary. 

Suction line is blocked.

Remove or flush obstruction. Check and clear all suction screens or strainers.

Excessive suction lift.

For lifts exceeding 20’ of liquid, filling the chambers with liquid will prime the pump in most cases.

Suction side air leakage or air in product.

Visually inspect all suction-side gaskets and pipe connections.

Pumped fluid in air exhaust muffler.

Disassemble pump chambers. Inspect for diaphragm rupture or loose diaphragm plate assembly. 

Pump Cycles Running  

Sluggish / Stalling, 

Flow Unsatisfactory

Over lubrication.

Set lubricator on lowest possible setting or remove. Units are designed for lube free operation.

Icing.

Remove muffler screen, de-ice, and re-install. Install a point of use air drier. 

Clogged manifolds.

Clean manifolds to allow proper air flow.

Deadhead (system pressure meets or exceeds air 

supply pressure).

Increase the inlet air pressure to the pump. Pump is designed for 1:1 pressure ratio at zero flow. 

 

(Does not apply to high pressure 2:1 units).

Cavitation on suction side.

Check suction (move pump closer to product).

Lack of air (line size, PSI, CFM).

Check the air line size, length, compressor capacity.

Excessive suction lift.

For lifts exceeding 20’ of liquid, filling the chambers with liquid will prime the pump in most cases.

Air supply pressure or volume exceeds system hd.

Decrease inlet air (press. and vol.) to the pump. Pump is cavitating the fluid by fast cycling. 

Undersized suction line.

Meet or exceed pump connections. 

Restrictive or undersized air line.

Install a larger air line and connection. 

Suction side air leakage or air in product.

Visually inspect all suction-side gaskets and pipe connections.

Suction line is blocked.

Remove or flush obstruction. Check and clear all suction screens or strainers.

Pumped fluid in air exhaust muffler.

Disassemble pump chambers. Inspect for diaphragm rupture or loose diaphragm plate assembly. 

Check valve obstructed.

Disassemble the wet end of the pump and manually dislodge obstruction in the check valve pocket. 

Check valve and/or seat is worn or needs adjusting.

Inspect check valves and seats for wear and proper setting. Replace if necessary.

Entrained air or vapor lock in chamber(s).

Purge chambers through tapped chamber vent plugs. Purging the chambers of air can be dangerous. 

Product Leaking 

Through Exhaust

Diaphragm failure, or diaphragm plates loose.

Replace diaphragms, check for damage and ensure diaphragm plates are tight.

Diaphragm stretched around center hole or bolt holes. Check for excessive inlet pressure or air pressure. Consult Chemical Resistance Chart for compatibility 

with products, cleaners, temperature limitations and lubrication.

Premature Diaphragm 

Failure

Cavitation.

Enlarge pipe diameter on suction side of pump.

Excessive flooded suction pressure.

Move pump closer to product. Raise pump/place pump on top of tank to reduce inlet pressure.

 

Install Back pressure device (Tech bulletin 41r). Add accumulation tank or pulsation dampener.

Misapplication (chemical/physical incompatibility).

Consult Chemical Resistance Chart for compatibility with products, cleaners, temperature limitations 

and lubrication.

Incorrect diaphragm plates or plates on backwards, 

installed incorrectly or worn.

Check Operating Manual to check for correct part and installation. Ensure outer plates have not been 

worn to a sharp edge.

Unbalanced Cycling 

Excessive suction lift.

For lifts exceeding 20’ of liquid, filling the chambers with liquid will prime the pump in most cases.

Undersized suction line.

Meet or exceed pump connections.

Pumped fluid in air exhaust muffler.

Disassemble pump chambers. Inspect for diaphragm rupture or loose diaphragm plate assembly.

Suction side air leakage or air in product.

Visually inspect all suction-side gaskets and pipe connections.

Check valve obstructed.

Disassemble the wet end of the pump and manually dislodge obstruction in the check valve pocket. 

Check valve and/or seat is worn or needs adjusting.

Inspect check valves and seats for wear and proper setting. Replace if necessary. 

Entrained air or vapor lock in chamber(s).

Purge chambers through tapped chamber vent plugs. 

UNIVERSAL ALL SANDPIPER, EXCEPT FLAP

2: INST

AL

 & OP

Summary of Contents for Signature Series

Page 1: ...800 N Main St Mansfield Ohio 44902 USA Telephone 419 524 8388 Fax 419 522 7867 SANDPIPERPUMP COM Copyright 2017 Warren Rupp Inc All rights reserved Certified Quality ISO 9001 Certified ISO 14001 Certi...

Page 2: ...d for materials that tend to settle out or solidify the pump should be flushed after each use to prevent damage In freezing temperatures the pump should be completely drained between uses Before pump...

Page 3: ...ECTION 3 EXPLODED VIEW 7 Composite Repair Parts Drawing Composite Repair Parts List Material Codes SECTION 4 AIR END 10 Air Distribution Valve Assembly Air Valve with Stroke Indicator Assembly Pilot V...

Page 4: ...2 50 2 SB Stainless Brass sleeve and spool set Discharge Porting Position D Top Suction Bottom Discharge Your Serial fill in from pump nameplate ______________________________________ __ __ _____ __...

Page 5: ...resistance 250 F 121 C 0 F 18 C Santoprene Injection molded thermoplastic elastomer with no fabric layer Long mechanical flex life Excellent abrasion resistance 275 F 135 C 40 F 40 C UHMW PE A thermo...

Page 6: ...505 9 81 249 21 64 550 20 30 516 2 61 66 2 61 66 OPTIONAL VERTICAL SUCTION PORT OPTIONAL VERTICAL DISCHARGE PORT 2 55 65 2 64 67 17 69 449 2 59 66 7 06 179 13 56 344 2 NPT 2 BSPT SUCTION PORT 2 NPT 2...

Page 7: ...directions are controlled by the check valves ball or flap orientation The pump primes as a result of the suction stroke The suction stroke lowers the chamber pressure P3 increasing the chamber volume...

Page 8: ...supply may cause icing or freezing of the exhaust air causing the pump to cycle erratically or stop operating Water in the air supply can be reduced by using a point of use air dryer Air Inlet and Pri...

Page 9: ...nt of use air drier Clogged manifolds Clean manifolds to allow proper air flow Deadhead system pressure meets or exceeds air supply pressure Increase the inlet air pressure to the pump Pump is designe...

Page 10: ...Kit Bumpers Bushings Gaskets O rings Seals Plungers and Retaining Rings 476 270 360 Wet End Kit Nitrile Diaphragms Nitrile Flaps Nitrile Hinge Pads Nitrile Wear Pads sealing washers 476 270 363 Wet E...

Page 11: ...scharge w cast iron wetted 2 312 013 110 Elbow Discharge w stainless wetted 2 22 338 005 360 Valve Flap Assembly Buna 4 338 005 363 Valve Flap Assembly FKM 4 338 005 364 Valve Flap Assembly EPDM 4 338...

Page 12: ...prene Rubber Color coded GREEN 366 Food Grade Nitrile 368 Food Grade EPDM 371 Philthane Tuftane 374 Carboxylated Nitrile 375 Fluorinated Nitrile 378 High Density Polypropylene 379 Conductive Nitrile 4...

Page 13: ...PORTANT Read these instructions completely before installation and start up It is the responsibility of the purchaser to retain this manual for reference Failure to comply with the recommendations sta...

Page 14: ...O Rings 1 3 E 560 023 360 O Ring Spool 2 3 F 675 037 080 Retaining Ring 1 3 A 3 F 3 D 3 B 3 C 3 E Pilot Valve Servicing With Pilot Valve removed from pump Step 1 Remove snap ring 3 F Step 2 Remove sl...

Page 15: ...together Torque values are called out on the exploded view Repeat procedure for second side assembly Allow a minimum of 15 minutes to elapse after torquing then re torque the assembly to compensate f...

Page 16: ...A1 2009 Pumps and Pump Units for Liquids Common Safety Requirements to verify conformance 5 YEAR Limited Product Warranty Warren Rupp Inc Warren Rupp warrants to the original end use purchaser that n...

Page 17: ...knowledge apply to the listed equipment AODD Pumps and Surge Suppressors Technical File No 203104000 1410 MER AODD Air Operated Double Diaphragm Pumps EC Type Examination Certificate No Pumps KEMA 09A...

Reviews: