s30nmdl2sm-rev0614
Model S30 Non-Metallic Page 33
Leak Detection Options Drawing
LEAK DETECTION OPTION (ELECTRONIC)
Follow instructions found elsewhere in this manual, “Filling the
Spill Containment Chambers” when installing leak detectors.
Electronic Leak Detector Installation
Kit 032-037-000
100VAC
50Hz
or
110-120VAC
50/60Hz
or 220-240VAC
50/60Hz
Kit 032-045-000
12-32VDC
To install electronic leak detectors, remove the bottom ¼" NPT pipe
plug on the visual sight tube (item 52). Insert leak detector into the
¼" pipe tee (item 56).
LEAK DETECTION OPTION (MECHANICAL)
Follow instructions found elsewhere in this manual, “Filling
the Spill Containment Chambers” when installing leak detectors.
Mechanical Leak Detector Installation
Kit 031-023-110
To install mechanical leak detectors, remove the bottom ¼" NPT
pipe plug on the visual sight tube (item 52). Insert leak detector
into the ¼" pipe tee (item 56).
For pumps with
530-028-550
ENCLOSED MUFFLER