MAN UP CAGE
a) This attachment fits onto the forks. Space Forks centrally on carriage & to the correct width of
channels on man up cage remove locating pin & lock pins & drive into cage locating both
channels fully. Place locating pins in into rear of channels behind fork heels & FIT Lock pins DO
NOT use cage if any part is not fitted correctly or missing.
b) The cage must be secure for operatives, ensure that the chain securing the opening is fitted.
c) The cage floor must be clear & undamaged.
d) The Safe Working Load (SWL) is 500kgs. This is a maximum load that applies to the cage,
carriage and forks.
e) The cage is designed for TWO MEN only. NO LIFTING load is allowed when used as a Man Up
cage
f) When cage is fitted operatives are must not travel in cage when the Teleporter is moving. The
operatives may only enter cage once the Teleporter is at the required site.
g)
The cage must only be allowed for maintenance jobs only
. (this is a Legal Requirement for
use of man up cage)
h)
Any person using the man up cage shall do so wearing the tested, safety harness provided
by the club and be attached to the man up cage at all times.