5 MAINTENANCE MODE
5.1 Normal Mode Operation
Unless the system is started up in “maintenance mode”, it will automatically
power-up in “Normal” flight operations mode.
5.2 Maintenance Mode
To access the Maintenance Mode, prior to applying power to the system, press
and hold the
[BRG 1] [BRG 2]
selection buttons then apply power and wait until
the Maintenance Index page is displayed. Then release these buttons.
From the maintenance mode the system normal operations can be accessed by
holding the “M” button for approximately 3 seconds. This feature can be used to
test or see the results of a change in maintenance page configuration. The
maintenance pages can be brought back by holding the “M” button again for 3
seconds.
NOTE: WHEN DOING A FINAL TEST OF A SYSTEM MAKE SURE THE
POWER HAS BEEN RECYCLED TO VERIFY CORRECT SETTINGS.
To exit the maintenance mode for normal flight operations turn off the power for
15 seconds and restart the unit normally.
82002-IM-L
ST3400 INSTALLATION MANUAL
5-1
Summary of Contents for ST3400
Page 24: ...THIS PAGE INTENTIONALLY LEFT BLANK ST3400 INSTALLATION MANUAL 82002 IM L 2 6 ...
Page 44: ...THIS PAGE INTENTIONALLY LEFT BLANK 5 2 ST3400 INSTALLATION MANUAL 82002 IM L ...
Page 75: ...THIS PAGE INTENTIONALLY LEFT BLANK 82002 IM L ST3400 INSTALLATION MANUAL 7 31 ...
Page 76: ......
Page 78: ...THIS PAGE INTENTIONALLY LEFT BLANK 8 2 ST3400 INSTALLATION MANUAL 82002 IM L ...
Page 80: ...THIS PAGE INTENTIONALLY LEFT BLANK 9 2 ST3400 INSTALLATION MANUAL 82002 IM L ...
Page 86: ...THIS PAGE INTENTIONALLY LEFT BLANK 11 2 ST3400 INSTALLATION MANUAL 82002 IM L ...
Page 88: ...12 2 STC Cessna 421C Series 12 2 ST3400 INSTALLATION MANUAL 82002 IM L ...
Page 89: ...12 3 STC King Air C90 200 300 and B300 Series 82002 IM L ST3400 INSTALLATION MANUAL 12 3 ...
Page 91: ......
Page 92: ......