APPENDIX B: Environmental Qualification
82011-IM, REV J
Sandel SG102 & MT102 Installation Manual
Page 10-4
RTCA/D0-160E Environmental Qualification – MT102 All Variants
NAMEPLATE NOMENCLATURE: [A2F2X]BBB[H(RP)R(BB1CC1EE1GJ)U2(FF1)]XWXXXXBXXX[ZW][YY]M[A3J33]XXAX
MODEL/PART NO: MT102 Magnetic
Transducer
TSO NUMBERS: C6d
MANUFACTURER’S SPECIFICATION AND/OR OTHER APPLICABLE SPECIFICATION:
MANUFACTURER: Sandel Avionics, Inc.
ADDRESS: 2401 Dogwood Way
Vista, CA 92081
REVISION & CHANGE NOS. OF DO-160: Revision E
DATE TESTED:
From: 7/05/07 To: 1/15/08
ENVIRONMENTAL
TESTS
RTCA
DO-160E
SECTION
Equipment
Test
Category
Notes
Temperature & Altitude
In-Flight Loss of Cooling
Altitude
-Decompression
-Overpressure
4.0
4.5.5
4.6.1
4.6.2
4.6.3
A2F2
X
F2
A2
A2
PASS
Not Applicable
PASS
PASS
PASS
Temperature Variation
5.0
B
PASS:
Humidity
6.3.1
B
PASS
Operational Shock and Crash Safety
7.0
B
PASS
Vibration
8.0
[H(RP)R(BB1
CC1EE1GJ)
U2(FF1)]
PASS:
160E Section 8.6: HLSD, Curves R and P
160E Section 8.7.2: Robust, Curves B B1 C C1 E
E1
160E Section 8.8.1: SoR, Curves G J
160E Section 8.8.3: Rondom (unknown freq.),
Curves F F1
SAE AS396B: Zone 1 (Fuselage), Max.
Accel=5g, 5-500Hz
Explosion
9.0
X
n/a
Water-proofness
10.0
W
PASS: Drip proof. Cat. Y, condensation,
applicable.
Fluids Susceptibility
11.0
X
n/a
Sand and Dust
12.0
X
n/a
Fungus
13.0
X
n/a
Salt Spray
14.0
X
n/a
Magnetic Effect
15.0
B
PASS
Power Input
16.0
X
n/a
Voltage Spike
17.0
X
n/a
Audio Frequency Susceptibility
18.0
X
n/a
Induced Signal Susceptibility
19.0
ZW
PASS
Radio Frequency Susceptibility
20.0
[YY]
PASS
Radio Frequency Emission
21.0
M
PASS
Lightning Induced Transient
Susceptibility
22.0
[A3J33]
PASS
Lightning Direct Effects
23.0
X
n/a
Icing
24.0
X
n/a
Electrostatic Discharge
25.0
A
PASS
Fire, Flammability
26.0
X
n/a